HÖRMANN 560

Hormann 560 Control Unit User Manual

Model: 560

1. Introduction

This manual provides essential information for the installation, operation, and maintenance of the Hormann 560 Control Unit. The 560 Control Unit is a reliable control board specifically designed for industrial gate control, optimized for use with WA500 drives. It offers functionalities such as partial opening, enhancing the efficiency and flexibility of industrial sectional doors.

Please read this manual thoroughly before attempting to install or operate the device. Keep this manual for future reference.

2. Safety Instructions

Always observe the following safety precautions to prevent injury or damage to the control unit and associated equipment:

  • Installation and maintenance should only be performed by qualified personnel.
  • Disconnect power before performing any installation, maintenance, or troubleshooting.
  • Ensure all wiring connections comply with local electrical codes and regulations.
  • Protect the control unit from moisture, dust, and extreme temperatures.
  • Do not modify the control unit or its components. Use only original spare parts.
  • Keep children and unauthorized persons away from the operating area of the gate system.

3. Product Overview

The Hormann 560 Control Unit consists of a power and control board designed for precise and safe operation of industrial sectional doors. It is an ideal replacement part for existing control systems.

Hormann 560 Control Unit showing various ports and connectors

Figure 1: Top view of the Hormann 560 Control Unit, highlighting its various connection points and labels. Visible labels include X90, X93, X91 for power input, PE for ground, X1, X2, X3, X22, X23 for terminal blocks, and X20, X21, X30, X50, X51, X70, X200a, X200b for various communication and control ports. The unit also shows labels for fuses (T10A H250V) and bus connections.

3.1. Components and Connectors

  • X90, X91, X93: Power input terminals (N, L1, L2, L3).
  • PE: Protective Earth connection.
  • X1, X2, X3, X22, X23: Terminal blocks for various control signals and accessories.
  • X20, X21, X30, X50, X51, X70: RJ45 or similar ports for communication and external devices.
  • X200a, X200b: BUS connections for system integration.
  • T10A H250V: Fuse location.
  • PRG: Programming port/button.

4. Setup and Installation

The Hormann 560 Control Unit is designed for integration with Hormann WA500 drives. Follow these general steps for installation. Refer to the specific WA500 drive manual for detailed wiring diagrams and mounting instructions.

  1. Mounting: Securely mount the control unit in a suitable, protected enclosure, away from direct moisture and excessive vibrations.
  2. Power Connection: Connect the main power supply to terminals X90, X91, X93 (N, L1, L2, L3) and the protective earth to PE. Ensure correct phase sequence if applicable.
  3. Motor Connection: Connect the WA500 drive motor to the designated terminals on the control unit.
  4. Safety Devices: Connect all necessary safety devices (e.g., photocells, safety edges) to the appropriate terminals (e.g., X1, X2, X3).
  5. Control Devices: Connect push buttons, key switches, or other control devices to the relevant input terminals.
  6. Bus Connections: If integrating with other system components, connect via the BUS ports (X200a, X200b).
  7. Initial Power-Up: After all connections are secure and verified, apply power to the unit. Observe any indicator lights for proper initialization.

5. Operating Instructions

The Hormann 560 Control Unit facilitates the operation of industrial sectional doors, including a partial opening function for enhanced flexibility.

5.1. Standard Operation

  • Opening: Press the designated 'Open' button or activate the corresponding input. The gate will open to its fully open position.
  • Closing: Press the designated 'Close' button or activate the corresponding input. The gate will close to its fully closed position.
  • Stop: Press the 'Stop' button to halt the gate's movement at any point.

5.2. Partial Opening Function

The partial opening function allows the gate to open to a pre-defined intermediate position, useful for pedestrian access or smaller vehicle passage without fully opening the large industrial door.

  • Activation: The partial opening function is typically activated via a dedicated input or a specific sequence on a multi-function button. Consult your system's configuration for exact activation methods.
  • Adjustment: The partial opening height can usually be adjusted during the initial setup or through the control unit's programming interface (PRG port). Refer to the programming manual for detailed steps.

6. Maintenance

Regular maintenance ensures the longevity and reliable operation of your Hormann 560 Control Unit and the associated gate system.

  • Visual Inspection: Periodically inspect the control unit for any signs of damage, loose connections, or dust accumulation.
  • Cleaning: Gently clean the exterior of the unit with a dry, soft cloth. Do not use liquid cleaners or solvents.
  • Connection Check: Ensure all terminal connections remain tight and secure.
  • Fuse Check: If the unit loses power, check the T10A H250V fuse. Replace only with a fuse of the same type and rating.
  • System Check: Regularly test all safety devices (photocells, safety edges) and the emergency stop function of the gate system.

For complex maintenance or repairs, contact a qualified service technician.

7. Troubleshooting

This section provides solutions to common issues you might encounter with the Hormann 560 Control Unit. For problems not listed here, contact technical support.

ProblemPossible CauseSolution
Unit has no power.No main power supply; Blown fuse; Loose power connection.Check main power supply; Replace T10A H250V fuse; Verify all power connections (X90, X91, X93, PE).
Gate does not respond to commands.Safety device activated; Control input not connected or faulty; Motor connection issue.Check all safety devices (photocells, safety edges) for obstructions or faults; Verify control wiring; Inspect motor connections.
Gate stops unexpectedly.Obstruction detected by safety device; Overload protection activated.Remove any obstructions; Check for excessive friction in gate movement; Allow unit to cool down if overloaded.
Partial opening not working.Function not configured; Incorrect activation method.Verify partial opening configuration in the system settings; Ensure correct button or input is used.

8. Specifications

AttributeDetail
BrandHÖRMANN
Model560 Control Unit
CompatibilityHormann WA500 drives
Dimensions (L x W x H)6 x 17.2 x 22 cm
Weight0.5 grams (likely 0.5 kg or 500 grams, given the size)
ColorBlack
ASINB0DJCZGR9L
First AvailableOctober 2, 2024

Note: The weight specification of "0.5 grams" appears to be an error in the source data and likely refers to 0.5 kg or 500 grams for a control unit of this size.

9. Warranty and Support

The Hormann 560 Control Unit is a high-quality product designed for durability and reliable performance. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact Hormann customer service directly.

For technical support, troubleshooting assistance beyond this manual, or to inquire about spare parts, please contact your authorized Hormann dealer or visit the official Hormann website. When contacting support, please have your product model (560) and ASIN (B0DJCZGR9L) ready.

Note: Spare parts availability information was not provided in the product data.

© 2024 Hormann. All rights reserved.

This manual is for informational purposes only. Specifications are subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.