1. Important Safety Information

WARNING: Ozone is a powerful oxidant and can be harmful if inhaled directly. This device is designed for use in unoccupied spaces only.

  • Always ensure no people, pets, or plants are present in the treatment area during operation.
  • After treatment, ventilate the area thoroughly for at least 30 minutes before re-entry. Open windows and doors to allow fresh air to circulate.
  • Do not operate the unit in wet or damp conditions.
  • Keep out of reach of children.
  • Ensure the power cord is not damaged and is properly connected to a grounded outlet.
  • Do not attempt to disassemble or repair the unit yourself. Contact customer service for assistance.
  • This product is not available for sale in California.

2. Product Overview

The LANDNOR Model 002 Ozone Generator is a high-capacity commercial-grade machine designed for effective odor removal and air purification in various environments. It features a robust all-metal casing, a powerful fan, and a timer function for controlled operation.

Key Features:

  • High Ozone Output: 90,000 mg/h for efficient odor elimination.
  • Large Coverage Area: Effective for spaces up to 6,000 square feet.
  • Adjustable Timer: Up to 120 minutes, with a 'HOLD' setting for continuous operation.
  • Durable Construction: Strong, all-metal casing for extended service life.
  • Portable Design: Compact (7 x 6.8 x 5.5 inches) and lightweight (4.9 pounds) with a metal handle for easy transport.
  • Low Noise Operation: Operates at less than 36dB.
LANDNOR Ozone Generator in a living room setting

Figure 1: LANDNOR Ozone Generator in a living room. This image shows the compact design and the control panel with the timer knob and run mode indicator.

3. Package Contents

Verify that all items are included in your package:

  • LANDNOR Ozone Generator Unit
  • Power Cable
  • Instruction Manual
  • "NO ENTRY" Door Hanger Notice
Package contents of LANDNOR Ozone Generator

Figure 2: Included items: Ozone Generator, Door Hanger Notice, Instruction Manual, and Power Cable.

4. Setup

  1. Prepare the Area: Remove all people, pets, and plants from the room or vehicle to be treated. Close all windows and doors to create an enclosed space.
  2. Place the Unit: Position the ozone generator in the center of the treatment area, or in a location that allows for optimal air circulation. Ensure it is on a stable, dry surface.
  3. Connect Power: Plug the power cable into the unit and then into a standard AC 110V-120V/60Hz grounded electrical outlet.
  4. Display Warning: Place the "NO ENTRY" door hanger on the entrance to the treatment area to warn others.

5. Operating Instructions

Follow these steps for safe and effective operation:

  1. Clean the Room: Before ozone treatment, clean the room to remove the source of odors. This enhances the effectiveness of the ozone generator.
  2. Set the Timer: Turn the timer knob to the desired treatment duration (up to 120 minutes). For continuous operation, select the 'HOLD' setting. Refer to the "Recommended Operating Time" table below for guidance.
  3. Start Operation: The unit will begin generating ozone once the timer is set. The "RUNMODE" indicator light will illuminate.
  4. Evacuate the Area: Immediately leave the room or vehicle once the unit starts operating. Ensure no one enters the area during treatment.
  5. Ventilation After Treatment: Once the timer completes and the unit switches off, wait at least 30 minutes before re-entering the treated space. Open all windows and doors to ventilate the area thoroughly.
  6. Repeat Treatment: Repeat the treatment regularly or if lingering odors persist.
Four steps for using the LANDNOR Ozone Generator

Figure 3: Visual guide to the four main operating steps: Clean the room, Set time, Leave the room, and Ventilate.

Recommended Operating Time:

The optimal treatment time depends on the size of the area and the intensity of the odor. Start with shorter durations and adjust as needed.

Area Size (Square Feet)Recommended Time (Minutes)
100 SQFT7 MIN
200 SQFT15 MIN
300 SQFT30 MIN
400 SQFT45 MIN
500 SQFT60 MIN
1000+ SQFTHOLD Mode
Recommended operating times for different room sizes

Figure 4: Chart illustrating recommended operating times based on room size.

6. Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your ozone generator.

  • Cleaning the Fan: The unit features a removable fan for easy cleaning. Periodically clean the fan and the ozone plates to prevent dust buildup, which can reduce efficiency.
  • Ozone Plate Replacement: The ceramic ozone plates have a long service life of approximately 6,000 hours. If you notice a significant decrease in ozone output or effectiveness, the plates may need replacement. Contact customer service for replacement parts.
Removable fan for easy cleaning on LANDNOR Ozone Generator

Figure 5: The removable fan design allows for easy cleaning to maintain air flow and unit efficiency.

7. Troubleshooting

If you encounter issues with your LANDNOR Ozone Generator, refer to the following common solutions:

  • Unit Not Turning On:
    • Ensure the power cable is securely plugged into both the unit and a working electrical outlet.
    • Check if the power outlet is functional by plugging in another device.
    • Verify the timer knob is set to a duration or 'HOLD' mode, not 'OFF'.
  • Low Ozone Output / Ineffective Odor Removal:
    • Ensure the treatment area is properly sealed (windows and doors closed).
    • Clean the fan and ozone plates as described in the Maintenance section.
    • Increase the treatment duration or use the 'HOLD' mode for larger or more severely affected areas.
    • Consider if the ozone plates need replacement (after approximately 6,000 hours of use).
  • Unusual Noises:
    • Check for any obstructions around the fan or inside the unit.
    • Ensure the unit is placed on a stable, flat surface to prevent vibrations.

If the problem persists after attempting these solutions, please contact LANDNOR customer service for further assistance.

8. Specifications

SpecificationDetail
Brand NameLANDNOR
Model Number002
Ozone Production90,000 mg/h
Power Consumption120W
Power SupplyAC 110V-120V/60Hz
Air Flow Volume110 CFM
Cooling ModeAir Cooling
Noise Level<36dB
Unit Weight4.85 lbs (2.2 KG)
Product Dimensions (L x W x H)10.08 x 8.86 x 7.6 inches
Timer0-120 Minutes or HOLD Mode
Contaminant Filtration CapabilityOdors
Dimensions of the LANDNOR Ozone Generator

Figure 6: Detailed dimensions of the LANDNOR Ozone Generator.

9. Warranty and Support

LANDNOR commercial ozone generators come with a one-year extended warranty.

For any questions about the product, technical support, or warranty claims, please contact LANDNOR customer service. We aim to respond within 24 hours.

Note: Statements regarding dietary supplements have not been evaluated by the FDA and are not intended to diagnose, treat, cure, or prevent any disease or health condition. This note is included as per product information, though not directly related to the ozone generator's function.

Related Documents - 002

Preview Ozone Calibration to NIST Traceability: Forensics Detectors Analyzer and 2B Technologies Calibration Source SOP
Comprehensive documentation detailing ozone calibration procedures, NIST traceability, and calibration certificates for Forensics Detectors and 2B Technologies ozone measurement instruments. Includes Standard Operating Procedure SOP-CAL-002 for calibrating ozone gas detectors.
Preview Standard Operating Procedure for Calibration of Ozone Gas Detectors
This Standard Operating Procedure (SOP) outlines the method for calibrating ozone (O3) gas detectors, ensuring accurate measurements in accordance with ISO/IEC 17025:2017. It covers equipment, materials, procedures, documentation, and quality control for ozone detector calibration.
Preview Fibaro Smoke Sensor FGSD-002-EN-A-v1.00 Operating Manual
Comprehensive operating manual for the Fibaro Smoke Sensor FGSD-002-EN-A-v1.00, detailing its features, installation, Z-Wave integration, alarm functions, and advanced configuration for smart home safety.
Preview Mazda Air Conditioning Musty/Mildew Odor Service Bulletin
Technical service bulletin addressing musty/mildew odors in Mazda vehicles due to mold growth in the A/C evaporator. Provides a solution using Mazda Air Cooling Coil Coating.
Preview Fibaro Smoke Sensor FGSD-002: Instrukcja Obsługi i Funkcje
Dowiedz się więcej o Fibaro Smoke Sensor FGSD-002, zaawansowanym detektorze dymu i temperatury kompatybilnym z Z-Wave. Instrukcja obsługi, funkcje i specyfikacje techniczne.
Preview FNIRSI SG-002 ±12V/0-24mA Voltage and Current Signal Generator User Manual
User manual for the FNIRSI SG-002, a versatile ±12V/0-24mA voltage and current source signal generator. This guide covers technical specifications, power supply options, dimensions, wiring diagrams, operational modes, parameter settings, and current output testing methods.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.