Leakbee R502

Leakbee RV Dual LP/CO Alarm (Model R502) Instruction Manual

Your Guide to Safe Operation and Maintenance

1. Introduction

The Leakbee RV Dual LP/CO Alarm, Model R502, is designed to provide continuous monitoring for both carbon monoxide (CO) and propane (LP) gas leaks within recreational vehicles. This device features two independent, highly sensitive sensors to ensure the safety of occupants in motorhomes, travel trailers, motor coaches, and truck campers. This manual provides essential information for proper installation, operation, and maintenance of your alarm.

Package Contents:

  • 1x Leakbee R502 RV 2-in-1 CO & Propane Gas Detector
  • 1x Flush Mount Bracket
  • 1x Universal Long & Short Surface Mount Bracket
  • 1x Lever-nut Connector
  • 1x User Manual (this document)
  • 6x Screws (2x Mounting Screws, 4x Fixing Bracket Screws)
Contents of the Leakbee R502 RV Dual LP/CO Alarm package

Image 1.1: The package includes the R502 detector, various mounting brackets, a lever-nut connector, screws, and the user manual.

2. Safety Information

Please read and understand all safety instructions before installing or operating this device. Failure to follow these instructions may result in property damage, injury, or death.

  • This alarm is designed for 12V DC power systems only. Do not connect to AC power.
  • Ensure proper polarity during wiring (red to positive, black to negative) to prevent damage.
  • Do not paint the alarm. Paint can clog the sensor openings and interfere with proper operation.
  • The alarm will not operate without power. Ensure a continuous 12V DC power supply.
  • Test the alarm regularly as described in the maintenance section.
  • Replace the alarm 60 months (5 years) after its first power-on date. An 'E' displayed on the screen indicates end-of-life.
  • In case of an alarm, immediately ventilate the area and investigate the source of the leak.

3. Setup and Installation

The Leakbee R502 offers versatile installation options with included brackets. Choose the bracket that best suits your RV's interior.

3.1 Choosing an Installation Location

  • Install the alarm approximately 4-12 inches (10-30 cm) from the floor. Propane gas is heavier than air and tends to settle low. Carbon monoxide mixes with air.
  • Avoid installing near windows, doors, or vents where drafts could affect sensor readings.
  • Do not install near cooking appliances, furnaces, or other heat sources.
  • Ensure the alarm is not obstructed by furniture or curtains.
RV interior showing the recommended installation height for the LP/CO alarm

Image 3.1: The alarm should be installed 4-12 inches (10-30 cm) from the floor in an RV living space.

3.2 Mounting Options

The R502 comes with three types of brackets for flexible installation:

  • Flush Mount Bracket: For a recessed installation, providing a sleek, integrated look.
  • Short Surface Mount Bracket: For surface mounting where minimal protrusion is desired.
  • Long Surface Mount Bracket: For surface mounting, offering more space behind the unit if needed.
Diagram showing flush, short, and long mounting bracket options for the RV alarm

Image 3.2: The alarm can be installed using flush, short surface, or long surface mounting brackets to suit various RV wall types and existing cutouts.

3.3 Wiring Connection

The R502 utilizes a lever-nut connector for simplified and secure wiring.

  1. Strip approximately 1/2 inch (12mm) of insulation from the ends of your RV's 12V DC power wires.
  2. Open the orange levers on the lever-nut connector.
  3. Insert the stripped red wire from the alarm into the positive (+) terminal of your RV's 12V DC power supply. Insert the stripped black wire from the alarm into the negative (-) or ground terminal.
  4. Close the orange levers to secure the wires. Ensure a firm connection.

Important: Ensure 12V to red (+) and ground to black (-) to prevent damage to the unit.

Step-by-step guide for connecting wires using the lever-nut connector

Image 3.3: Detailed steps for using the lever-nut connector for a secure electrical connection.

4. Operating Instructions

Once properly installed and powered, the Leakbee R502 will begin monitoring for CO and LP gas.

4.1 Initial Power-Up

Upon initial power connection, the alarm will perform a self-test. The digital display may show various numbers or symbols, and the indicators will cycle. After a brief warm-up period, the green POWER indicator light should illuminate, indicating normal operation.

4.2 Indicators and Display

The R502 features a digital LED display and indicator lights:

  • Digital LED Display: Shows the concentration level of carbon monoxide (in PPM) or propane (in %LEL) when detected.
  • CO Indicator: Illuminates when carbon monoxide is detected.
  • LP Indicator: Illuminates when propane gas is detected.
  • POWER Indicator (Green): Indicates the unit is receiving power and operating normally.
Front view of the Leakbee R502 alarm showing the digital display, CO, LP, and Power indicators, and Test/Mute button

Image 4.1: The R502 alarm with its digital display and indicator lights.

4.3 Alarm Conditions

The alarm provides both visual and audible warnings:

  • Audible Alarm: Emits an 85-decibel warning sound.
  • Visual Alarm: The digital display will show the detected gas level, and the corresponding CO or LP indicator will illuminate.

In the event of an alarm:

  1. Immediately open all windows and doors to ventilate the RV.
  2. Turn off all gas appliances and the main gas supply.
  3. Evacuate all occupants from the RV.
  4. Do not re-enter until the alarm has ceased and the area has been thoroughly ventilated.
  5. Identify and rectify the source of the leak. If unable to do so, seek professional assistance.

4.4 Test/Mute Button

Press the TEST/MUTE button to:

  • Test the Alarm: A short press will initiate a self-test, activating the audible alarm and illuminating all indicators.
  • Mute the Alarm: During an active alarm, a short press will temporarily silence the audible alarm for a few minutes. The visual indicators will remain active until the gas concentration drops to a safe level.
  • Turn off Display: A long press (3 seconds) and release of the button can turn off the bright digital number display for nighttime use.

5. Maintenance

Regular maintenance ensures the continued reliability of your Leakbee R502 alarm.

5.1 Regular Testing

Test the alarm weekly by pressing the TEST/MUTE button. The alarm should sound, and indicators should light up. If the alarm does not respond, refer to the troubleshooting section.

5.2 Cleaning

Clean the exterior of the alarm periodically with a soft, damp cloth. Do not use harsh chemicals or abrasive cleaners. Ensure no dust or debris obstructs the sensor openings.

5.3 End-of-Life Indication and Replacement

The Leakbee R502 has a service life of 5 years (60 months) from its first power-on. When the unit reaches its end-of-life, the digital display will show an 'E'.

Digital display of the Leakbee R502 alarm showing an 'E' for End-of-Life

Image 5.1: The 'E' on the display indicates the alarm has reached its end-of-life and requires replacement.

Upon seeing the 'E' indication, replace the alarm immediately to ensure continued protection.

6. Troubleshooting

This section addresses common issues you might encounter with your Leakbee R502 alarm.

ProblemPossible CauseSolution
Alarm sounds continuously or frequently.Presence of CO or LP gas; false alarm due to strong fumes (e.g., cleaning products, exhaust).Ventilate the RV immediately. Check for gas leaks. If no leak is found, ventilate thoroughly to clear fumes. If alarms persist, seek professional inspection.
No power / Green POWER light off.No 12V DC power supply; incorrect wiring; blown fuse in RV's electrical system.Check RV's 12V DC power supply. Verify wiring connections (red to +, black to -). Check and replace any blown fuses.
Digital display shows 'E'.Alarm has reached its end-of-life (5 years).Replace the alarm unit immediately.
Alarm does not respond to TEST/MUTE button.No power; unit malfunction.Check power supply. If power is present and the unit still doesn't respond, the unit may be faulty and requires replacement.

7. Specifications

FeatureSpecification
BrandLeakbee
Model NumberR502
Power SourceCorded Electric (12 Volts DC)
Voltage12 Volts (DC)
Wattage1 watt
Product Dimensions3.78"D x 2.72"W x 0.79"H (9.6cm D x 6.9cm W x 2.0cm H)
Item Weight6.7 ounces (190g)
ColorWhite
Alarm TypeVisual & Audible Alarm (85 dB)
Sensor TypePhotoelectric
Upper Temperature Rating50 Degrees Celsius (122°F)
MaterialPlastic
Service Life5 years (60 months) from first power-on
Batteries Included/RequiredNo
Diagram showing the dimensions of the Leakbee R502 alarm and its mounting options

Image 7.1: Detailed dimensions of the R502 alarm and its various mounting configurations.

8. Warranty and Support

Leakbee products are designed for reliability and performance. For warranty information or technical support, please refer to the contact details provided with your purchase or visit the official Leakbee website. Keep your purchase receipt as proof of purchase for warranty claims.

Note on Videos: No official product videos from the seller were available for embedding in this manual.

© 2025 Leakbee. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.