1. Introduction
The HuBDIC Hubicare Hand Massager, Model FE-0161, is designed to provide targeted relief for hand and wrist discomfort. It combines deep shiatsu kneading, strong air compression, and adjustable heat and cooling functions to promote circulation, reduce stiffness, and alleviate pain associated with conditions such as arthritis, carpal tunnel syndrome, and repetitive strain. This manual provides essential information for safe and effective use of your device.

Figure 1: HuBDIC Hubicare Hand Massager with heat and cooling functions shown in use.
Key Features:
- Deep Tissue Hand Massage: Combines shiatsu kneading and air compression for comprehensive relief from fingers to wrist.
- Temperature Regulation: Dual heat levels (40–45°C) and a built-in cooling fan to manage warmth and moisture.
- Multiple Therapy Modes: 6 therapy modes and 2 pressure levels, including a high-intensity option for deep tissue stimulation.
- Full Palm and Wrist Coverage: Designed to treat the entire hand and wrist area with an adjustable strap for secure fit.
- Cordless and Rechargeable: Powered by a 3000mAh battery for portable use, offering 4–6 hours of operation per charge.
- Easy to Use: Features preset 10, 15, and 20-minute sessions and a user-friendly touchscreen interface.
2. Safety Information
Please read all instructions carefully before using the device and keep them for future reference.
- This device is not a medical device.
- Do not use if you have implanted medical devices such as pacemakers.
- Not suitable for children under 12 years of age.
- Stop using immediately if you experience discomfort, numbness, or swelling.
- For first-time users, it is recommended to start with level 1 intensity without the roller kneading function, as high pressure and rolling may feel intense.
- Ensure the air release valve at the bottom of the device is in the "OFF" (Sealed Mode) position before use.
- Statements regarding dietary supplements have not been evaluated by the FDA and are not intended to diagnose, treat, cure, or prevent any disease or health condition.
3. Setup and Charging
3.1 Unboxing and Initial Inspection
Carefully remove the hand massager and all accessories from the packaging. Inspect the device for any signs of damage. Ensure all components, including the USB-C charging cable, are present.
3.2 Charging the Device
Before first use, fully charge the hand massager. The device is powered by a 3000mAh lithium-ion battery.
- Connect the provided USB-C cable to the charging port on the massager.
- Connect the other end of the USB-C cable to a compatible USB power adapter (not included) or a computer USB port.
- The battery indicator on the touchscreen display will show the charging status.
- A full charge provides approximately 4–6 hours of operation.

Figure 2: Large battery capacity and USB-C charging port for portability.
3.3 Air Release Valve
Locate the air release valve at the bottom of the massager. Ensure it is in the "OFF" (Sealed Mode) position before operating the device to allow for proper compression. In case of emergency or to quickly release pressure, switch the valve to the "ON" (Emergency Deflate) position.
4. Operating Instructions
The Hubicare Hand Massager features a user-friendly touchscreen interface for easy control of all functions.

Figure 3: Easy-to-control touchscreen operation panel.
4.1 Powering On/Off
- To power on, press and hold the Power Button (circular button in the center) for a few seconds.
- To power off, press and hold the Power Button again.
4.2 Selecting a Massage Mode
The massager offers 6 therapy modes. Press the Modes Button (labeled 'M') to cycle through the available options:
- Auto Massage
- Soothing Massage
- Hand Massage
- Circular Massage
- Relaxing Massage
- Palm & Wrist Massage

Figure 4: Overview of the 6 therapy modes and 6 intensity levels.
4.3 Adjusting Intensity Levels
There are 6 intensity levels for air compression, customizable to your preference. Press the Intensity Button (three vertical bars icon) to adjust the pressure. Levels 1-2 are for soft massage, 3-4 for comfort, and 5-6 for deep massage.
4.4 Heat and Cooling Functions
The massager features both heat and cooling functions for enhanced comfort and therapeutic benefits.
- Heat Function: Press the Heat Button (wavy lines icon) to activate. There are two heat levels (40°C and 45°C). Heating supports circulation and pain relief.
- Cooling Fan: Press the Fan Button (fan icon) to turn the cooling fan on or off. The cooling fan helps manage moisture and can be beneficial for inflammation.

Figure 5: Heat and cooling fan functions for temperature regulation.
4.5 Roller Kneading Function
The device includes a bi-directional roller kneading function for the palm area. Press the Kneading Button (circular arrow icon) to activate or deactivate this feature. This targets muscles and tendons in the palm for focused relief.
4.6 Setting the Timer
The massager has preset session durations. Press the Timer Button (clock icon) to select between 10, 15, or 20-minute sessions. The device will automatically shut off after the selected time.
4.7 Using the Wrist Coverage
The massager provides full palm and wrist coverage. An adjustable strap helps stabilize the device for consistent compression around the wrist, which is beneficial for carpal tunnel or reduced wrist strength.

Figure 6: Wrist air compression and adjustable wrist strap for secure fit.
5. Maintenance
Proper care and maintenance will ensure the longevity and optimal performance of your hand massager.
- Cleaning: Always unplug the appliance from the electrical outlet immediately after using and before cleaning. Wipe the exterior of the massager with a soft, damp cloth. Do not use abrasive cleaners or immerse the device in water.
- Storage: Store the massager in a cool, dry place away from direct sunlight and extreme temperatures.
- Battery Care: To prolong battery life, avoid fully discharging the battery frequently. Charge the device regularly, even if not in use for extended periods.
6. Troubleshooting
If you encounter any issues with your HuBDIC Hubicare Hand Massager, please refer to the following common troubleshooting tips:
- Device not turning on: Ensure the device is fully charged. Connect it to the charger and wait for the battery indicator to show sufficient charge.
- No compression or weak compression: Check that the air release valve at the bottom of the device is in the "OFF" (Sealed Mode) position. Ensure your hand is properly inserted and the adjustable strap is secured.
- Heat/Cooling not working: Verify that the heat or fan functions are activated via their respective buttons on the control panel.
- Discomfort during use: Reduce the intensity level. If discomfort persists, discontinue use and consult a healthcare professional. Remember to start with level 1 without the roller kneading function for first-time use.
7. Specifications
| Feature | Detail |
|---|---|
| Product Dimensions | 10.75 x 6.69 x 5.08 inches |
| Item Model Number | FE-0161 |
| Item Weight | 2.65 Pounds (1200 Grams) |
| Battery | 1 Lithium Ion battery required (included), 3000mAh |
| Power Source | Battery Powered |
| Voltage | DC 5V2A |
| Power | 10W |
| Material | Acrylonitrile Butadiene Styrene |
| Manufacturer | Xiamen Healthpal Electronic Co,.Ltd |
8. Official Product Videos
Watch these official videos from HuBDIC for a visual guide on using your hand massager.
HubiCare Hand Massager New Release
Video 1: An introductory video showcasing the features and benefits of the HubiCare Hand Massager. Duration: 0:44.
Introducing HubiCare Hand Massager
Video 2: A detailed introduction to the HubiCare Hand Massager, highlighting its design and functionality. Duration: 1:14.
9. Warranty and Support
For warranty information, technical support, or any inquiries regarding your HuBDIC Hubicare Hand Massager, please contact the manufacturer directly. Refer to the product packaging or the official HuBDIC website for contact details.