1. Introduction
The Aquastrong Mini Split HVAC Condensate Pump is designed for efficient and quiet removal of condensate from various HVAC systems. This automatic pump is ideal for air conditioners, furnaces, and dehumidifiers, ensuring proper drainage and preventing water buildup. Its compact design allows for flexible installation in various settings.

Image: Aquastrong Mini Split Condensate Removal Specialist, highlighting automatic, energy-saving, ultra-quiet, and high head features.
2. Safety Information
- Product is NOT submersible: This pump is designed for indoor use only and must not be submerged in water.
- Horizontal Installation: The pump must be installed horizontally to ensure proper operation.
- Indoor Use Only: This product is intended for indoor use exclusively.
- Outlet Pipe Placement: Ensure the outlet pipe is positioned higher than the reservoir to prevent siphoning.
- Mounting Restrictions: Do NOT mount the pump inside the air conditioner main unit or within the power line box.
- Secure Placement: Firm attachment with velcro strips on the bottom of the reservoir and main pump is recommended for stability.

Image: Important maintenance advice and precautions, including non-submersible and flat-level indoor mounting requirements.
3. Package Contents
The Aquastrong Mini Split HVAC Condensate Pump package includes the following components:
- Main Pump
- 1.2 oz Reservoir
- Sensor Cable
- 6-Pin Socket Lead Assembly
- 3.3ft Safety Switch Copper Wires
- 3.3ft UL Grounded Power Cord
- 3/5'' I.D. Silicone Tube
- 4/5'' x 3/5'' I.D. Inlet Adapter
- Barbed Adapter
- Breather Tube
- Velcro Strips
- Connector Tube

Image: Display of all included accessories and components for the Aquastrong Condensate Pump.
4. Specifications
| Feature | Specification |
|---|---|
| Brand | AQUASTRONG |
| Model Number | CDS036-4P |
| Max Flow Rate | 9.6 GPH (Gallons Per Hour) |
| Max Head | 33 ft |
| Voltage | 115V/230V |
| Power | 3W |
| Reservoir Capacity | 1.2 oz |
| Operating Temperature | 32°F - 122°F |
| Noise Level | Ultra-silent (approx. 20 dB) |
| Power Cord Length | 3.3 ft (UL certified) |
| Inlet Size | 3/5'' O.D. (with 3/5'' I.D. silicone tube & 4/5'' I.D. adapter) |
| Outlet Size | 3/10'' O.D. barbed (fits 1/4'' to 3/8'' I.D. vinyl tubing) |

Image: Detailed technical specifications and an output flow rate chart, illustrating pump performance relative to total head.

Image: Dimensions of the main pump and reservoir components.
5. Setup and Installation
The Aquastrong condensate pump features a mini split design with anti-vibration velcro strips, allowing for flexible installation in various locations such as line set covers, wall cassettes, or above ceilings. Follow these steps for proper setup:
- Positioning: Place the main pump and reservoir horizontally on a flat, stable surface indoors. Ensure the magnet on the reservoir faces upward.
- Inlet Connection: Connect the 3/5'' O.D. inlet of the reservoir to your HVAC unit's condensate drain. The package includes a 3/5'' I.D. silicone tube and a 4/5'' I.D. adapter for compatibility.
- Outlet Connection: Attach appropriate vinyl tubing (1/4'' to 3/8'' I.D.) to the 3/10'' O.D. barbed outlet. Ensure the outlet pipe is routed to a suitable drain location and is positioned higher than the reservoir to prevent backflow or siphoning.
- Sensor and Power Connection: Connect the sensor cable and the 6-pin power cable to the pump.
- Breather Tube: Install the breather tube to the vent port on the reservoir cap before use.
- Power Supply: Plug the 3.3ft UL power cord into a standard 115V/230V electrical outlet.
- Secure Mounting: Utilize the provided velcro strips to firmly attach the main pump and reservoir, minimizing vibration and ensuring stability.
Note: Inlet/Outlet drains (tubing) are not included and need to be purchased separately.

Image: Diagram illustrating the flexible installation options for the mini split design in small spaces, including evaporator coil, above ceiling, condensate drain tray, and below collector pan connections.

Image: Visual guide for easy installation, showing connections for power, sensor, inlet, outlet, and breather tube.

Image: Close-up view of the 3/5" O.D. reservoir inlet and the 1/3" top vent port, with installation tips.

Image: Details on the built-in check valve and the barbed inlet/outlet connections, with tips for connecting cables and tubes.
6. Operation
The Aquastrong condensate pump operates automatically, utilizing a reliable hall switch to detect water levels in the reservoir. When the water level rises, the pump automatically activates to drain the condensate. It stops when the water level is low, ensuring efficient and quiet operation.
- Automatic Start/Stop: The built-in sensitive hall switch automatically starts the pump when the water level in the tank rises and stops at a low level.
- Ultra-Silent Operation: Designed for quiet performance, the pump operates at approximately 20 dB, making it suitable for living rooms or bedrooms.
- Hi-level Safety Switch: Signal lead wires are provided for connection to HVAC appliances or alarms. If the sensor detects high water levels, the safety switch will trigger to automatically shut off the appliance (using NC & COM wires) or activate an alarm (using NO & COM wires) to prevent overflow.
- Thermal Overload Protection: The pump is equipped with thermal protection. If operation with insufficient water causes abnormally high temperatures, the thermal protection will be triggered, and the pump will automatically shut off to prevent damage.

Image: Features of auto and quick condensate removal, including max flow, tank capacity, voltages, and max head.

Image: Explanation of the automatic operation feature, emphasizing the sensitive hall switch and the importance of magnet orientation.

Image: Diagram showing the wiring for the reliable hi-level safety switch, with connections for appliance (NC & COM) and alarm (NO & COM).

Image: Further details on the high-level safety switch, including the three copper wire signal lines (purple NC, green NO, red COM).

Image: Description of the thermal overload protection feature, explaining how it prevents damage from high temperatures due to water shortage.

Image: Close-up of the 3.3ft UL power cord with a 3-prong plug, emphasizing safe and simple operation.
7. Maintenance
Regular maintenance is crucial for the longevity and optimal performance of your Aquastrong condensate pump. It is necessary to clean the reservoir, float, and filter at least every six months to prevent clogging and ensure continuous operation.
- Cleaning Frequency: Clean the reservoir, float, and filter at least every six months.
- Removable Filter: The metal inlet filter is removable, making it easy to clean out large debris and prevent clogging.
- Visible Tank: The visible tank design allows for easy observation of internal conditions, facilitating timely cleaning.

Image: Features of the visible design and removable filter, highlighting ease of observation and cleaning to prevent clogging.
8. Troubleshooting
While this manual does not contain a dedicated troubleshooting guide, common issues can often be resolved by reviewing the installation and maintenance sections. Ensure all connections are secure, the pump is installed horizontally, and the reservoir and filter are clean. If the pump is not operating, check the power supply and verify that the water level in the reservoir is sufficient to trigger the pump.
For persistent issues, please refer to the support information below.
9. Warranty and Support
Aquastrong customer service is available to provide professional technical support for your condensate pump. For any questions, concerns, or assistance, please contact Aquastrong customer service.
While specific warranty details are not provided in this manual, please retain your proof of purchase for any warranty claims.
Visit the official AQUASTRONG Store for more information and products.