1. Introduction

Thank you for choosing the Nyxi 12000 BTU Portable Air Conditioner. This 3-in-1 unit provides efficient cooling, dehumidification, and fan-only modes, designed for optimal comfort in your home or office. Please read this manual thoroughly before operation to ensure proper use, maintenance, and safety.

2. Product Overview

2.1 Key Features

  • 3-in-1 Functionality: Cooling (12,000 BTU/2500W), Dehumidification (28.8 Litre per Day), and Fan-Only Mode.
  • Energy Efficiency: Utilizes advanced energy-saving technology for reduced electricity consumption.
  • Eco-Friendly Refrigerant: Uses R290 refrigerant, which is significantly more eco-friendly.
  • Portable Design: Compact and slim profile with four casters and two side handles for easy mobility.
  • Digital Display & Remote Control: Equipped with a digital display for current settings and room temperature, and an LCD remote for convenient operation.
  • Sleep Mode: Advanced sleep mode for reduced overnight energy consumption.
  • 24-Hour Timer: Allows for optimized usage and scheduled operation.
  • Self-Evaporative System: Reduces the need for frequent draining by recycling water for cooling.

2.2 Components and Parts

Familiarize yourself with the main components of your portable air conditioner:

  • Main Unit
  • Exhaust Hose
  • Window Kit (adjustable from 65cm to 130cm)
  • Square Adaptor (for connecting AC to exhaust hose)
  • Round Adaptor (for connecting exhaust hose to window kit)
  • Draining Pipe
  • LCD Remote Control
Nyxi 12000 BTU Portable Air Conditioner with accessories

Figure 2.2.1: Nyxi Portable Air Conditioner main unit, remote control, exhaust hose, and window kit components.

Detailed view of Nyxi Portable Air Conditioner features including handles, casters, air outlet, filter, remote, and drainage ports.

Figure 2.2.2: Close-up views of the unit's convenient handles, casters for mobility, adjustable air outlet, removable air inlet filter, control panel with remote, and options for manual or continuous drainage.

3. Setup and Installation

Proper installation is crucial for the efficient operation of your air conditioner. Follow these steps carefully:

3.1 Placement

  • Place the unit on a flat, stable surface.
  • Ensure there is at least 30 cm (12 inches) of space around the unit for proper airflow.
  • Avoid placing the unit in direct sunlight or near heat sources.

3.2 Exhaust Hose Installation

  1. Attach the square adaptor to the exhaust hose by twisting it clockwise.
  2. Connect the other end of the exhaust hose to the round adaptor.
  3. Insert the square adaptor into the exhaust outlet on the back of the air conditioner unit.
  4. Extend the exhaust hose to the nearest window.

3.3 Window Kit Installation

  1. Adjust the window kit to fit your window opening. The kit is adjustable from 65cm to 130cm.
  2. Secure the window kit in the window frame.
  3. Insert the round adaptor (with the exhaust hose attached) into the opening of the window kit, ensuring a tight seal to prevent hot air from re-entering the room.
  4. For casement windows, place the window outlet outside the window.
Nyxi Portable Air Conditioner with dimensions and exhaust hose setup

Figure 3.3.1: Illustration of the air conditioner's dimensions and the exhaust hose and window kit setup.

4. Operation

Your Nyxi portable air conditioner can be operated using the control panel on the unit or the included LCD remote control.

4.1 Control Panel and Remote Functions

  • Power Button: Turns the unit ON or OFF.
  • Mode Button: Press to cycle through Cooling, Dehumidification (Dry), and Fan-Only modes.
  • Fan Speed Button: Adjusts fan speed (High/Low) in Cooling or Fan-Only modes.
  • Temperature Up/Down Buttons: Adjusts the desired room temperature (16°C to 32°C).
  • Timer Button: Sets the 24-hour timer for automatic ON/OFF.
  • Sleep Button: Activates sleep mode, dimming indicators and automatically adjusting fan speed for quiet operation.
  • Auto Swing: Enables the AC to horizontally oscillate its vents, dispersing air evenly.

4.2 Operating Modes

Cooling Mode

Select this mode for cooling. Set your desired temperature using the Up/Down buttons. The unit will cool until the room reaches the set temperature.

Dehumidification Mode (Dry)

This mode removes excess moisture from the air. The unit can remove up to 28.8 litres per day. In this mode, the fan speed is typically fixed. For continuous dehumidification, connect the draining pipe to the continuous drainage port.

Nyxi Portable Air Conditioner in dehumidification mode, showing moisture removal

Figure 4.2.1: The unit operating in dehumidification mode, effectively reducing humidity for a more comfortable environment and aiding in drying clothes.

Fan-Only Mode

Circulates air without cooling. You can adjust the fan speed in this mode.

4.3 Timer Function

The 24-hour timer allows you to program the unit to turn ON or OFF automatically. Refer to the remote control instructions for detailed timer setup.

4.4 Sleep Mode

Activate sleep mode for quieter operation and reduced energy consumption during sleep. Indicators will dim, and fan speed will automatically adjust.

Nyxi Portable Air Conditioner highlighting high efficiency and sleep mode

Figure 4.4.1: The unit's high efficiency features, including the eco-friendly R290 refrigerant and the energy-saving sleep mode for quiet overnight operation.

5. Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your air conditioner.

5.1 Cleaning the Air Filter

  • It is recommended to clean the air filter every 2 weeks, or more frequently depending on usage and air quality.
  • Turn off and unplug the unit before cleaning.
  • Remove the air filter from the back of the unit.
  • Wash the filter with warm, soapy water. Rinse thoroughly and allow it to air dry completely before reinserting.

5.2 Draining Water

The unit has a self-evaporative system, which reduces the need for frequent draining. However, in high humidity conditions, the water tank may fill up. The unit will stop operating and display an error code when the tank is full.

  • Manual Drainage: Place a shallow pan or tray under the drainage port at the bottom of the unit. Remove the drain plug to allow water to flow out. Replace the plug once drained.
  • Continuous Drainage: For continuous operation in dehumidification mode, connect the provided draining pipe to the continuous drainage port. Ensure the pipe is sloped downwards to allow gravity drainage into a suitable container or floor drain.

5.3 Storage

If storing the unit for an extended period:

  • Drain all accumulated water from the unit.
  • Clean the air filter.
  • Store the unit in a dry, upright position, away from direct sunlight and extreme temperatures.

6. Troubleshooting

Before contacting customer support, please refer to the following troubleshooting guide:

ProblemPossible CauseSolution
Unit does not turn on.No power, power cord unplugged, circuit breaker tripped.Check power connection, ensure outlet is functional, reset circuit breaker.
Unit cools insufficiently.Air filter dirty, exhaust hose not properly installed, room too large, windows/doors open.Clean air filter, ensure exhaust hose is sealed, close windows/doors, check room size suitability.
Unit is noisy.Unit not on a level surface, fan obstruction.Place unit on a flat surface, check for obstructions in fan area. (Note: 53 dB is normal operating noise).
Water leakage.Drain plug loose, continuous drainage hose kinked or blocked.Ensure drain plug is secure, check continuous drainage hose for kinks or blockages.
Remote control not working.Batteries dead, obstruction between remote and unit.Replace batteries, remove obstructions, ensure remote is pointed at the unit's receiver.

7. Specifications

SpecificationValue
BrandNyxi
Model3683584-683577
Cooling Capacity12,000 BTU / 2500W
Dehumidification Capacity28.8 Litre per Day
Air Volume450 m³/h
Noise Level53 dB
RefrigerantR290
Voltage250 Volts
Wattage2600 watts
Product Dimensions (H x W x L)71 cm x 44 cm x 33.5 cm
Item Weight29.5 kg
Energy EfficiencyA+

8. Safety Information

Please read and follow all safety instructions to prevent injury or damage.

  • Always unplug the unit before cleaning or performing any maintenance.
  • Do not operate the unit with a damaged cord or plug.
  • Do not block air inlets or outlets.
  • Keep children and pets away from the unit during operation.
  • Do not use the unit in wet or damp environments.
  • Ensure the unit is placed on a stable, level surface to prevent tipping.
  • Only use the accessories provided or recommended by the manufacturer.

9. Warranty and Support

For warranty information and customer support, please refer to the documentation included with your purchase or contact Nyxi customer service through the retailer where the product was purchased. Please have your model number (3683584-683577) and purchase date available when contacting support.