1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your NHJLFKSA EK2R-2P100 Dual Power Automatic Transfer Switch (ATS). The ATS is designed to automatically switch between two power sources, such as city power and a generator or inverter, ensuring an uninterruptible power supply for critical loads. Please read this manual thoroughly before installation and use.
2. Safety Instructions
WARNING: Electrical shock hazard. Installation and servicing should only be performed by qualified personnel.
- Always disconnect all power sources before installing or servicing the ATS.
- Ensure proper grounding of the device.
- Verify that the voltage and current ratings of the ATS match your electrical system requirements.
- Do not operate the ATS if it appears damaged.
- Adhere to all local electrical codes and regulations.
3. Product Overview
3.1 Features
The NHJLFKSA EK2R-2P100 ATS offers the following key features:
- Automatic transfer between two power sources (e.g., city power and generator/inverter).
- Short-circuit and overload protection.
- Over-voltage and under-voltage protection.
- Open-phase automatic conversion function.
- Intelligent alarm functions.
- Din Rail mounting for easy installation.
3.2 Components
The ATS unit consists of the following main components:
- Power Input Terminals: Labeled "City Power" (Source A) and "Generator" (Source B).
- Load Output Terminals: Connect to the electrical load.
- Control Terminals: For external control or monitoring.
- Manual/Auto Switch: Allows selection between manual and automatic operation modes.
- Indicator Lights: To show the active power source.

Figure 1: Front view of the NHJLFKSA EK2R-2P100 Automatic Transfer Switch, showing input terminals for City Power and Generator, output terminals, and the Manual/Auto selector switch.

Figure 2: Side view of the NHJLFKSA EK2R-2P100 ATS, illustrating its robust design and highlighting features such as short-circuit and overload protection.
4. Installation
4.1 Mounting
The EK2R-2P100 ATS is designed for Din Rail mounting. Ensure the mounting location is dry, well-ventilated, and free from excessive vibrations or corrosive gases. Mount the unit vertically to allow for proper heat dissipation.
- Securely attach a standard 35mm Din Rail to a suitable surface within your electrical panel.
- Clip the ATS onto the Din Rail, ensuring it is firmly seated.
4.2 Wiring
IMPORTANT: All wiring must comply with local and national electrical codes. Consult a qualified electrician if you are unsure about any wiring procedures.
- Disconnect all power sources before beginning any wiring.
- Connect Main Power (Source A): Connect the "City Power" input terminals (labeled 'Source A' on the device, with terminals like NC C NO AR AN) to your primary power source (e.g., utility grid).
- Connect Secondary Power (Source B): Connect the "Generator" input terminals (labeled 'Source B' on the device, with terminals like NC C NO BR BN) to your secondary power source (e.g., generator or inverter).
- Connect Load: Connect the load circuit to the output terminals of the ATS.
- Grounding: Ensure proper grounding for both power sources and the ATS unit.
- Verify Connections: Double-check all wiring for correct polarity and secure connections. Loose connections can cause overheating and fire hazards.
Note: The device supports 2P (two-pole) and 4P (four-pole) configurations, and is rated for 220V systems. Ensure your specific model (e.g., 4P 100A) matches your application.
5. Operating Instructions
The EK2R-2P100 ATS features a Manual/Auto selector switch for operational control.
5.1 Automatic Mode
- Set the selector switch to "Auto".
- In this mode, the ATS will automatically detect the presence and quality of power from Source A (City Power) and Source B (Generator/Inverter).
- If Source A is present and within acceptable parameters, the ATS will connect the load to Source A.
- If Source A fails or falls outside acceptable parameters, the ATS will automatically switch the load to Source B (if Source B is available and stable).
- When Source A returns to normal, the ATS will automatically transfer the load back to Source A after a pre-set delay (if applicable).
5.2 Manual Mode
- Set the selector switch to "Manual".
- In Manual mode, the user can manually select the desired power source using the red rotary switch (visible in Figure 1).
- Caution: Ensure that the selected source is stable and capable of supplying the load before manually switching. Manual operation should only be performed by knowledgeable personnel.
6. Maintenance
Regular maintenance ensures the longevity and reliable operation of your ATS.
- Periodic Inspection: Annually inspect the ATS for any signs of physical damage, loose connections, or discoloration due to overheating.
- Cleaning: Keep the unit clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
- Terminal Check: Periodically check all terminal connections to ensure they are tight.
- Function Test: If safe to do so, periodically test the automatic transfer function by simulating a primary power failure.
Always disconnect power before performing any maintenance.
7. Troubleshooting
This section provides solutions to common issues. For problems not listed here, contact qualified service personnel.
| Problem | Possible Cause | Solution |
|---|---|---|
| ATS does not transfer power. | No power from primary/secondary source; ATS in Manual mode; faulty wiring. | Check power sources; set ATS to Auto mode; inspect wiring connections. |
| Load not receiving power. | Both power sources are off; circuit breaker tripped; internal fault. | Verify power source availability; check and reset circuit breakers; contact support if problem persists. |
| Overload alarm. | Connected load exceeds ATS capacity. | Reduce connected load; ensure total load does not exceed the ATS's rated current (e.g., 100A for this model). |
8. Specifications
The following specifications apply to the NHJLFKSA EK2R-2P100 Automatic Transfer Switch (4P 100A variant):
| Attribute | Value |
|---|---|
| Model Number | EK2R-2P100 |
| Brand | NHJLFKSA |
| Type | Dual Power Automatic Transfer Switch |
| Poles | 4P (also available in 2P variants) |
| Rated Current | 100A (variant specific, other variants include 40A, 63A, 125A) |
| Rated Voltage | 220V AC |
| Insulation Voltage | 690V AC |
| Impact-Resistant Voltage | 8kV |
| Material | Copper |
| Mounting Type | Din Rail |
| Item Weight | 1.76 ounces |
| Package Dimensions | 1.18 x 0.79 x 0.39 inches |
9. Warranty and Support
For warranty information and technical support, please refer to the documentation provided with your purchase or contact the seller directly. Keep your purchase receipt as proof of purchase.