1. Introduction
Thank you for choosing the Sunicon RL 2401 24V DC Diaphragm Water Pressure Pump. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your pump. Please read this manual thoroughly before use and retain it for future reference.
The Sunicon RL 2401 is a compact and efficient diaphragm pump designed for various applications requiring small flow and high pressure. It features a self-priming function and a built-in pressure protection switch for enhanced safety and reliability.
2. Safety Information
Always observe the following safety precautions to prevent injury or damage to the pump:
- Electrical Safety: Ensure the power supply matches the pump's voltage (24V DC). Incorrect voltage can damage the pump.
- Dry Environment: This pump is designed for use in dry and ventilated places. DO NOT immerse the pump in water or operate it in wet conditions.
- Liquid Compatibility: The pump is suitable for liquids without oil, strong acids, strong alkalis, or solid particles. Pumping incompatible liquids can cause damage.
- Temperature: Do not operate the pump in extreme temperatures.
- Connections: Ensure all electrical and water connections are secure and leak-free before operation.
- Children and Pets: Keep the pump out of reach of children and pets.
3. Product Overview
The Sunicon RL 2401 is a robust and compact diaphragm pump. Key features include self-priming capability, a pressure protection switch, and suitability for various non-corrosive liquids.

Figure 1: Sunicon RL 2401 24V DC Diaphragm Pump in operation, demonstrating its use for car cleaning. The image also highlights key features such as self-priming, built-in pressure protection, small size, high flow, and suitability for various liquids.

Figure 2: Detailed view of the Sunicon RL 2401 pump, displaying its product label with model number (RL-2401), voltage (24V), max amps (0.8A), max flow (0.5GPM/2.0LPM), and pressure off (55PSI/3.8BAR).
4. Specifications
Detailed technical specifications for the Sunicon RL 2401 24V DC Diaphragm Pump:
| Feature | Specification |
|---|---|
| Item Type | Diaphragm Pump |
| Material | Plastic |
| Weight | Approx. 650g (1.43 lbs) |
| Dimensions (L x W x H) | 165 x 99 x 62mm (6.50 x 3.90 x 2.44 inches) |
| Water Inlet/Outlet Connector | G1/4, applicable to G3/8, hose barb |
| Working Mode | Intermittent |
| Voltage | 24V DC |
| Max Amps | 0.8A |
| Max Flow | 0.5 GPM (2.0 LPM) |
| Pressure Off | 55 PSI (3.8 BAR) |
| Rated Power | 32W |
| Rated Current | 1.7A |
5. Setup and Installation
The Sunicon RL 2401 pump is designed for convenient installation. Follow these steps for proper setup:
5.1 Mounting the Pump
- Choose a dry, well-ventilated location for installation.
- Ensure the pump is mounted securely on a stable surface to prevent vibration and movement during operation.
- Allow sufficient space around the pump for air circulation and easy access for connections and maintenance.
5.2 Water Connections

Figure 3: Top-down view of the pump, illustrating the G1/4 water inlet and outlet connectors (compatible with G3/8 hose barb) and the electrical wiring.
- Connect the water inlet to your water source using appropriate G1/4 or G3/8 hose barb fittings.
- Connect the water outlet to your desired application (e.g., spray nozzle, filter system).
- Ensure all connections are tight and sealed to prevent leaks. Use thread sealant or PTFE tape if necessary.
5.3 Electrical Connections

Figure 4: Close-up view of the pump's electrical wiring, showing the red and black wires for power connection.
- Connect the pump to a stable 24V DC power source.
- Ensure correct polarity: typically, red wire for positive (+) and black/blue wire for negative (-). Refer to the pump's label for specific wiring instructions.
- It is recommended to install an appropriate fuse or circuit breaker in the power line to protect the pump and electrical system.
6. Operating Instructions
Follow these guidelines for safe and effective operation of your Sunicon RL 2401 pump:
6.1 Initial Start-up
- Before applying power, ensure all water connections are secure and the pump is properly mounted.
- Open any valves in the water line to allow water to flow to the pump.
- Apply 24V DC power to the pump. The pump will begin to operate.
- Due to its self-priming function, the pump will draw water and expel air from the system. This may take a few moments.
- Once water flows steadily, check for any leaks.
6.2 Pressure Protection Switch
- The pump is equipped with an automatic pressure protection switch.
- If the outlet pressure exceeds the set threshold (55 PSI / 3.8 BAR), the pump will automatically stop to prevent damage.
- The pump will automatically restart once the pressure drops below the threshold, for example, when a nozzle is opened or demand increases.
6.3 Dry Running
- The pump can run dry for a short period (no more than 30 minutes) without damage due to its self-priming design.
- However, prolonged dry running should be avoided as it can lead to premature wear and heat buildup.
6.4 Applications
The Sunicon RL 2401 pump is suitable for a wide range of applications, including:

Figure 5: Examples of diverse applications for the Sunicon RL 2401 pump, such as domestic water supply, garden spraying, high-pressure car washing, tap water boosting, solar water systems, and floor cleaning.
- Spray machines and cleaning devices with small flow and high pressure.
- Small flow water purification systems, filters, and chemical metering.
- Transfer, distribution, and filling of small flow food-grade liquids.
- Applicable in medicine, shipping, fishery breeding, industry, agriculture, and household use.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your pump:
- Cleaning: Periodically clean the exterior of the pump to prevent dust and debris buildup.
- Check Connections: Regularly inspect all water and electrical connections for tightness and signs of wear or corrosion.
- Filter Inspection: If your system includes an inlet filter, inspect and clean it regularly to prevent clogging and maintain flow.
- Winterization (if applicable): In freezing conditions, drain all water from the pump and lines to prevent damage from ice expansion. Store the pump in a warm, dry place.
- Storage: When not in use for extended periods, disconnect power, drain water, and store the pump in a dry, protected environment.
8. Troubleshooting
This section provides solutions to common issues you might encounter:
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power; Incorrect wiring; Blown fuse/breaker | Check power supply; Verify wiring polarity; Replace fuse/reset breaker |
| Pump runs but no water flows | Air in system; Inlet clogged; Insufficient water supply; Leaks in inlet line | Allow pump to self-prime; Check/clean inlet filter; Ensure adequate water source; Inspect inlet connections for leaks |
| Low flow or pressure | Clogged filter/nozzle; Air in system; Worn pump components | Clean filter/nozzle; Bleed air from system; Contact support if components are suspected to be worn |
| Pump cycles on/off rapidly | Small leak in system; Pressure switch malfunction; Restricted outlet flow | Check for leaks in plumbing; Ensure adequate flow at outlet; Contact support if pressure switch is faulty |
| Excessive noise/vibration | Loose mounting; Air in system; Debris in pump | Securely mount pump; Bleed air from system; Disconnect power and inspect pump for foreign objects |
If you encounter problems not listed here or if the suggested solutions do not resolve the issue, please contact Sunicon customer support.
9. Warranty and Support
For warranty information, please refer to the documentation provided at the time of purchase or contact your retailer. Sunicon is committed to providing quality products and customer satisfaction.
For technical support, spare parts, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt and product model number (RL 2401 24V) handy when contacting support.