1. Product Overview
The Argocima VIND EU WF is a versatile portable air conditioner designed to provide efficient cooling and dehumidification for your indoor spaces. With a cooling capacity of 10000 BTU and a Class A energy rating, it offers powerful performance while maintaining energy efficiency. Its portable design, complete with integrated handles and wheels, allows for easy relocation between rooms.

Figure 1: Front view of the Argocima VIND EU WF Portable Air Conditioner. The unit is white with a dark blue top panel, featuring an air outlet grille on the upper front and integrated handles on the sides.
Key Features:
- 10000 BTU Cooling Capacity
- Integrated Dehumidifier Function
- Class A Energy Efficiency
- Portable Design with Wheels
- Prefilter for Air Quality
- User-friendly Control Panel
2. Safety Information
Please read all safety warnings and instructions carefully before using this appliance to prevent injury or damage. Keep this manual for future reference.
General Safety:
- This appliance is for indoor use only.
- Do not operate the unit with a damaged cord or plug.
- Ensure the power supply matches the voltage specified on the rating label.
- Keep the unit away from heat sources, direct sunlight, and flammable materials.
- Do not block the air inlets or outlets. Maintain at least 30 cm (12 inches) clearance around the unit.
- Always unplug the unit before cleaning or performing any maintenance.
- Do not insert objects into the air outlets.
- Supervise children to ensure they do not play with the appliance.
Electrical Safety:
- Do not use extension cords or adapter plugs.
- Ensure the power cord is not pinched or damaged.
- Never pull the power cord to disconnect from the outlet. Grasp the plug firmly.
3. Setup and Installation
Unpacking:
- Carefully remove the unit from its packaging.
- Check for any shipping damage. If damaged, do not operate and contact your retailer.
- Retain the original packaging for future storage or transport.
Placement:
- Place the unit on a firm, level surface.
- Ensure there is at least 30 cm (12 inches) of space around the unit for proper airflow.
- Avoid placing the unit in direct sunlight or near heat-generating appliances.
Exhaust Hose Installation:
- Attach the exhaust hose connector to the back of the air conditioner.
- Extend the exhaust hose and connect the window kit adapter to the other end.
- Install the window kit into a suitable window opening, ensuring a tight seal to prevent air leakage.
- Direct the exhaust hose through the window kit to vent hot air outside. Keep the hose as short and straight as possible for optimal performance.
Drainage Setup (Dehumidifier Mode):
When operating in dehumidifier mode or for continuous drainage in cooling mode, connect a drainage hose (not supplied) to the continuous drainage port at the back of the unit. Ensure the hose is directed to a suitable drain or container, positioned lower than the unit's drainage port for gravity flow.
4. Operating Instructions
The control panel is located on the top of the unit. It features various buttons for mode selection, temperature adjustment, fan speed, and timer settings.
Control Panel Functions:
- Power Button: Turns the unit ON or OFF.
- Mode Button: Cycles through Cooling, Dehumidifier, and Fan modes.
- Temperature Up/Down Buttons: Adjusts the desired temperature in Cooling mode.
- Fan Speed Button: Selects fan speed (Low, Medium, High).
- Timer Button: Sets the auto-on or auto-off timer.
Operating Modes:
- Cooling Mode: Press the Mode button until the cooling indicator light illuminates. Use the temperature buttons to set your desired room temperature. The unit will cool the room to the set temperature.
- Dehumidifier Mode: Press the Mode button until the dehumidifier indicator light illuminates. In this mode, the unit will remove moisture from the air. The fan speed is typically fixed to low.
- Fan Mode: Press the Mode button until the fan indicator light illuminates. In this mode, the unit circulates air without cooling. You can adjust the fan speed.
Timer Function:
The timer allows you to set a specific time for the unit to turn ON or OFF automatically. Refer to the detailed instructions in your full manual for precise timer programming steps.
5. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your air conditioner. Always unplug the unit before cleaning.
Air Filter Cleaning:
- The prefilter should be cleaned every two weeks or more frequently depending on usage and air quality.
- Locate the air filter panel (usually at the back or side of the unit).
- Remove the filter.
- Wash the filter with lukewarm water and a mild detergent. Rinse thoroughly.
- Allow the filter to air dry completely before reinserting it into the unit. Do not expose to direct sunlight.
Water Tank Drainage:
- When the internal water tank is full, the unit may stop operating and display an indicator.
- Place a shallow pan or container under the drainage port.
- Remove the drain plug to allow water to flow out.
- Once drained, securely replace the drain plug.
Unit Cleaning:
- Wipe the exterior of the unit with a soft, damp cloth.
- Do not use harsh chemicals, abrasives, or solvents.
Storage:
- Before storing, ensure the unit is completely drained of water.
- Clean the air filter.
- Coil the power cord neatly.
- Store the unit in a cool, dry place, preferably in its original packaging.
6. Troubleshooting
Before contacting customer service, please refer to the following common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on. | No power supply; Power cord not plugged in; Circuit breaker tripped. | Check power outlet; Ensure plug is fully inserted; Reset circuit breaker. |
| Unit does not cool effectively. | Air filter clogged; Room too large; Doors/windows open; Exhaust hose not properly installed; Temperature setting too high. | Clean air filter; Ensure room size is appropriate; Close doors/windows; Check exhaust hose connection; Lower temperature setting. |
| Water leakage. | Drain plug loose; Unit not level; Continuous drainage hose blocked or improperly connected. | Secure drain plug; Place unit on a level surface; Check and clear drainage hose. |
| Unit is noisy. | Unit not on a level surface; Obstruction in fan. | Ensure unit is on a level surface; Check for and remove any obstructions. |
7. Specifications
| Specification | Value |
|---|---|
| Brand | Argo |
| Model Name | 398400030 |
| Cooling Capacity | 10000 British Thermal Units |
| Special Feature | Dehumidifier |
| BEE Star Rating | ≥ 3 stars |
| Seasonal Energy Efficiency Ratio (SEER) | 14 |
| Voltage | 230 Volts |
| Filter Type | Prefilter |
| Power Source | Corded Electric |
| Form Factor | Portable |
8. Warranty and Support
Warranty Information:
This product is covered by a warranty in accordance with local consumer protection laws. If you wish to return a product within 30 days of receipt because you have changed your mind, please consult the relevant return policy page. If you have received a defective or damaged product, please consult the relevant help page for defective/damaged products. For specific information on purchases made on the Marketplace, please consult the Marketplace help page.
For detailed warranty terms and conditions, please refer to the documentation provided with your purchase or contact your retailer.
Customer Support:
For technical assistance, troubleshooting beyond this manual, or spare parts, please contact the retailer or the manufacturer's authorized service center. Have your model number (398400030) and purchase date ready when contacting support.