FIABiomed 50x Kit

Precisa Blood Glucose Monitor Kit User Manual

Brand: FIABiomed | Model: 50x Kit

1. Introduction

The FIABiomed Precisa Blood Glucose Monitor Kit is designed to provide accurate and convenient blood sugar level monitoring. This comprehensive kit includes all necessary components for regular blood glucose testing at home. The monitor features a large, easy-to-read backlit display and an automatic shut-off function to conserve battery life. This manual provides detailed instructions for the safe and effective use of your Precisa Blood Glucose Monitor Kit.

Kit Contents:

  • Precisa Blood Glucose Monitor
  • 50 Precisa Glucometer Test Strips
  • 50 Sterile Lancets
  • Lancing Device
  • Control Solution
  • Carrying Case
  • User Manual (this document)
  • CR2032 Battery (pre-installed or included)
FIABiomed Precisa Blood Glucose Monitor Kit components including monitor, test strips, lancets, and lancing device.

Image: Overview of the Precisa Blood Glucose Monitor Kit components.

2. Safety Information

Please read all instructions carefully before using the Precisa Blood Glucose Monitor Kit. This device is intended for in-vitro diagnostic use by people with diabetes for self-testing outside the body.

  • Consult Your Healthcare Professional: Always consult with your doctor or healthcare provider before making any changes to your medication, diet, or exercise program based on your blood glucose results.
  • For Single Patient Use: The lancing device and lancets are for single-patient use only to prevent cross-contamination.
  • Proper Disposal: Dispose of used test strips and lancets in a proper sharps container to prevent injury and contamination.
  • Storage: Store the monitor, test strips, and control solution in a cool, dry place, away from direct sunlight and extreme temperatures. Keep out of reach of children.
  • Test Strip Expiration: Do not use expired test strips. Check the expiration date on the test strip vial.
Image showing the Precisa Blood Glucose Monitor is FDA approved and a Class II Medical Device.

Image: The Precisa Blood Glucose Monitor meets medical standards, is FDA approved, and is a Class II Medical Device.

3. Components Overview

Precisa Blood Glucose Monitor:

The monitor is the central unit for reading blood glucose levels. It features a large backlit display for easy viewing of results, time, and date. It has 'Set' and 'Mem' buttons for navigation and accessing stored readings.

Front and back view of the Precisa Blood Glucose Monitor.

Image: Front and back view of the Precisa Blood Glucose Monitor.

Test Strips:

Precisa test strips are designed for use with the Precisa monitor. Each strip contains chemicals that react with glucose in the blood sample to produce an electrical current, which the meter reads to determine the blood glucose level. Store test strips in their original vial and close the cap immediately after removing a strip.

Lancing Device and Lancets:

The lancing device is used to obtain a small blood sample, typically from the fingertip. It holds a sterile lancet, which is a small needle used to prick the skin. The device allows for adjustable penetration depth to minimize discomfort.

4. Setup

4.1 Battery Installation:

The Precisa Blood Glucose Monitor uses one CR2032 battery, which is included. The battery compartment is located on the back of the device. Ensure the battery is inserted with the correct polarity (+/-).

4.2 Setting Up the Lancing Device:

  1. Unscrew the cap of the lancing device.
  2. Insert a new sterile lancet firmly into the lancet holder.
  3. Twist off the protective cap of the lancet.
  4. Replace the lancing device cap.
  5. Adjust the penetration depth by rotating the cap. Start with a lower setting and increase if needed to get a sufficient blood sample.
  6. Pull back the cocking mechanism until it clicks, indicating it is ready to use.
Step-by-step guide for using the lancing device and performing a blood glucose test.

Image: Steps 1 and 2 illustrate setting the stitch depth and preparing the lancing device.

5. Operating Instructions

Performing a Blood Glucose Test:

The Precisa monitor provides fast and accurate results in approximately 5 seconds, requiring only a small blood sample (0.8 µL).

  1. Prepare Your Hands: Wash your hands thoroughly with soap and warm water, then dry them completely.
  2. Insert Test Strip: Remove a test strip from its vial and immediately close the vial cap. Insert the test strip into the test strip port of the meter. The meter will automatically turn on.
  3. Obtain Blood Sample: Use the prepared lancing device to prick the side of your fingertip. Gently squeeze your finger to form a small drop of blood.
  4. Apply Blood Sample: Touch the tip of the test strip to the blood drop. The blood will be drawn into the strip automatically. Do not apply blood to the top of the strip.
  5. Read Results: The meter will display your blood glucose result after approximately 5 seconds. The result will be stored in the meter's memory.
  6. Dispose: Carefully remove the used test strip and dispose of it along with the used lancet in a sharps container.
Steps 3 and 4 illustrating inserting the test strip and applying blood sample to the strip.

Image: Steps 3 and 4 show inserting the test strip to turn on the device and touching the side of the test strip with a blood sample.

Image showing lateral blood sampling and suitability for left-handed use.

Image: The device supports lateral blood sampling and is suitable for left-handed use, offering high result security and requiring fewer blood samples.

Image highlighting key features: 0.8 µL small blood amount, 5 seconds quick results, 800x large memory, no programming necessary.

Image: Key features of the Precisa monitor include a small blood requirement, quick results, large memory capacity, and no programming needed.

6. Maintenance and Care

Cleaning the Monitor:

Wipe the exterior of the monitor with a soft, damp cloth. Do not immerse the monitor in water or use harsh cleaning agents. Ensure no liquid enters the test strip port.

Storage:

Store the monitor and supplies in the provided carrying case. Keep them in a cool, dry place between 39.2°F and 104°F (4°C and 40°C) and relative humidity below 85%. Avoid direct sunlight and extreme temperatures.

Battery Replacement:

When the battery indicator appears on the display, replace the CR2032 battery promptly to ensure accurate readings.

7. Troubleshooting

  • Meter Does Not Turn On:

    Check if the battery is correctly installed. Replace the battery if necessary. Ensure a test strip is inserted correctly.

  • Error Message Displayed:

    Refer to the specific error code in the detailed manual (if available) or contact customer support. Common reasons include insufficient blood sample, expired test strip, or damaged test strip.

  • Inaccurate Readings:

    Ensure hands are clean and dry. Check test strip expiration date. Perform a control solution test to verify meter and strip accuracy. Ensure proper storage conditions for strips.

  • Difficulty Obtaining Blood Sample:

    Increase the penetration depth setting on the lancing device. Ensure proper technique for pricking the finger and forming a blood drop.

8. Specifications

Model Name50x Kit
BrandFIABiomed
ASINB0CZ78WXSN
ManufacturerHMD BioMedical Inc.
Package Dimensions6.1 x 4.21 x 2.05 inches
Weight6.38 ounces
Batteries1 CR2032 batteries required (included)
Unit Count50.0 Count (for test strips and lancets)
Blood Sample Volume0.8 µL (microliters)
Test TimeApproximately 5 seconds
Memory Capacity800 test results (from image)

9. Warranty and Support

Warranty Information:

The FIABiomed Precisa Blood Glucose Monitor Kit comes with a 5-year warranty. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.

Customer Support:

For technical assistance, troubleshooting, or warranty inquiries, please refer to the contact information provided in the packaging or visit the official FIABiomed website.

© 2024 FIABiomed. All rights reserved.

Ask a question about this manual