FeelTech FYA2010

FeelTech FYA2010 Signal Power Amplifier User Manual

Model: FYA2010 Series

Brand: FeelTech

1. Introduction

This user manual provides comprehensive instructions for the FeelTech FYA2010 series of 20W Signal Power Amplifiers. This device is designed to amplify various signal waveforms from digital DDS function generators with low distortion. Please read this manual thoroughly before operating the device to ensure proper use and to prevent damage.

Package Contents:

  • 1 x Signal Power Amplifier (FYA2010, FYA2030, FYA2050S, or FYA20A0S model)
  • 1 x Power Cable
  • 1 x BNC-BNC Cable
  • 1 x Q9 Clip Cable
  • 1 x User Manual
  • 1 x Quality Certificate

2. Safety Information

Observe the following safety precautions to prevent injury and damage to the device:

  • Ensure the power supply voltage matches the device's requirements (DC 15V).
  • Do not expose the device to moisture or extreme temperatures.
  • Do not open the casing or attempt to repair the device yourself. Refer all servicing to qualified personnel.
  • Use only the provided accessories or approved replacements.
  • Ensure proper ventilation to prevent overheating.

3. Product Overview

The FeelTech FYA2010 series amplifier is a compact and robust device designed for amplifying various signal waveforms from digital DDS function generators. It features full-band amplification and low distortion, making it suitable for a wide range of electronic testing and design applications.

Key Features:

  • Maximum amplified signal frequency: DC-1MHz (FYA2010), DC-3MHz (FYA2030), DC-5MHz (FYA2050S), DC-10MHz (FYA20A0S)
  • Low distortion, high precision signal amplification, compatible with all DDS signals.
  • Output voltage up to 28V (±14V).
  • Output current: 1000mA (MAX), max. output power 20W.
  • Magnification X2, X4 optional.
  • Slew rate: ≥500V/us.
  • DC15V power supply.
  • Input impedance: 10KΩ.
  • Exquisite aluminum alloy shell for effective heat dissipation.

Applications:

  • Electronic test and design
  • Sensor simulation and testing
  • Power device and circuit driving
  • Education and training
  • Selection and testing of piezoelectric components
  • Ultrasonic transducer drive
  • IF device driver
  • Medical cosmetic equipment drive
  • Remote sensing and detection equipment, wireless signal amplifier
FeelTech FYA2010 Signal Power Amplifier front view

Figure 3.1: Front view of the FeelTech FYA2010 Signal Power Amplifier, showcasing its compact design and robust casing.

FeelTech FYA2010 Signal Power Amplifier side view with heatsink

Figure 3.2: Side view of the amplifier, highlighting the integrated heatsink fins for efficient thermal management.

List of compatible signal sources and applications for FYA2000 series

Figure 3.3: A list detailing the major applications for the FYA2000 series and compatible signal sources from various manufacturers like FeelTech, Tektronix, Agilent, RIGOL, and Siglent.

4. Setup

Follow these steps to set up your FeelTech Signal Power Amplifier:

  1. Power Connection: Connect the provided DC 15V power adapter to the power input port on the rear panel of the amplifier. Ensure the power switch is in the OFF position before connecting.
  2. Signal Input: Use the BNC-BNC cable to connect your DDS function signal generator's output to the 'IN' BNC connector on the amplifier's rear panel.
  3. Signal Output: Connect your load or measurement device to the 'OUT' BNC connector using an appropriate BNC cable.
  4. Grounding: If necessary, connect the ground terminal to a suitable ground point.
  5. Initial Power-On: Once all connections are secure, switch the power toggle to the 'ON' position. The power indicator light should illuminate.
Rear panel of FeelTech FYA2010 Signal Power Amplifier showing input, output, power switch, and power connector

Figure 4.1: Rear panel connections including 'IN' and 'OUT' BNC ports, DC power input, ground terminal, and ON/OFF switch.

5. Operation

After successful setup, you can begin operating the amplifier:

  1. Power On: Ensure the amplifier is connected to power and your signal generator. Flip the power switch to 'ON'.
  2. Gain Selection: The amplifier offers fixed magnification modes of X2 and X4. Select the desired gain using the switch on the device, typically located near the input. Refer to the specific model for exact switch location.
  3. Signal Input: Generate the desired waveform from your DDS function generator. The amplifier is compatible with various waveforms including sine, square, pulse, sawtooth, triangle, ECG, and noise waves.
  4. Monitoring Output: Observe the amplified signal on your connected load or measurement device (e.g., oscilloscope). Adjust the input signal amplitude from your generator as needed, ensuring it does not exceed the amplifier's input amplitude range (≤14Vp-p).
  5. Power Off: When finished, switch the power toggle to 'OFF' and disconnect the power supply.

6. Maintenance

To ensure the longevity and optimal performance of your amplifier, follow these maintenance guidelines:

  • Cleaning: Use a soft, dry cloth to clean the exterior of the device. Do not use liquid cleaners or solvents.
  • Storage: Store the amplifier in a cool, dry place away from direct sunlight and corrosive environments when not in use.
  • Ventilation: Ensure the heatsink fins are free from dust and obstructions to maintain proper airflow and prevent overheating.

7. Troubleshooting

If you encounter issues with your amplifier, refer to the following common problems and solutions:

  • No Power:
    • Check if the power cable is securely connected to both the amplifier and the power outlet.
    • Verify that the power switch is in the 'ON' position.
    • Ensure the power adapter is functioning correctly and providing DC 15V.
  • No Output Signal:
    • Confirm that the input signal generator is producing a signal and is correctly connected to the 'IN' port.
    • Check the connection from the 'OUT' port to your measurement device or load.
    • Ensure the input signal amplitude is within the specified range (≤14Vp-p).
  • Distorted Output:
    • Reduce the input signal amplitude from your generator. The amplifier has a maximum output voltage of 28V (±14V).
    • Verify that the load impedance is appropriate (≥4Ω).
    • Check if the input signal frequency exceeds the maximum amplified frequency for your specific model (e.g., 1MHz for FYA2010).
  • Overheating:
    • Ensure the device has adequate ventilation and that the heatsink fins are not obstructed.
    • Reduce the operating time or the load if continuous high power output is causing excessive heat.

8. Specifications

Detailed technical specifications for the FeelTech FYA2010 series Signal Power Amplifiers:

Detailed technical specifications table for FYA2010S, FYA2030S, FYA2050S, FYA20A0S models

Figure 8.1: Comprehensive table outlining the specifications for different models within the FYA2000 series, including bandwidth, power, voltage, current, and physical dimensions.

ParameterSpecification
Model NumberGT-FYA2010
Signal Input BandwidthDC~1MHz (FYA2010), DC~3MHz (FYA2030), DC~5MHz (FYA2050S), DC~10MHz (FYA20A0S)
Maximum Output Power20W
Power Supply Input VoltageDC 15V
Power Supply Input Power≥30W
Input Impedance10KΩ
Input Amplitude Range≤14Vp-p
Output Amplitude≥28Vp-p (no-load)
Output Current1000mA (MAX)
Load Impedance≥4Ω (with maximum output power)
Slew Rate≥500V/us
Harmonic Distortion<1%
Over-current ProtectionYes
Gain Regulation ModeFixed magnification, X2 or X4
Operating EnvironmentTemperature: 0~60°C, Humidity: <80%
Dimensions (L*W*H)153 x 84 x 49 mm
Weight400g (without power supply), accessories 150g
MaterialAcrylonitrile Butadiene Styrene

9. Warranty and Support

The FeelTech FYA2010 series Signal Power Amplifier comes with a manufacturer's warranty. Please retain your proof of purchase for warranty claims.

Warranty Information:

  • EU Spare Part Availability Duration: 2 Years.
  • For specific warranty terms and conditions, please refer to the documentation included with your purchase or contact your retailer.

Customer Support:

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact your authorized FeelTech dealer or the point of purchase. Provide your model number (FYA2010) and a detailed description of the issue for efficient support.

Related Documents - FYA2010

Preview FeelTech FY3200S Series Dual-channel DDS Function / Arbitrary Waveform Signal Generator User's Manual
User's manual for the FeelTech FY3200S Series Dual-channel DDS Function and Arbitrary Waveform Signal Generator. This document provides detailed information on the instrument's features, technical specifications, operating procedures, safety precautions, and accessories.
Preview Инструкция по эксплуатации усилителя мощности FeelTech FYA20A0S
Полное руководство по эксплуатации, мерам предосторожности и техническим характеристикам усилителя мощности FeelTech FYA2000S серии.
Preview FeelTech FY3200S Series Dual Channel Function/Arbitrary Waveform Generator User's Manual
User's manual for the FeelTech FY3200S Series Fully Numerical Control Dual Channel Function/Arbitrary Waveform Generator, detailing its features, specifications, operation, and safety information.
Preview FeelTech FY3200S Series Dual Channel Function/Arbitrary Waveform Generator User's Manual
Comprehensive user's manual for the FeelTech FY3200S Series Dual Channel Function/Arbitrary Waveform Generator, detailing its features, specifications, and operation.
Preview FeelTech FY6600 Series Dual Channel Function/Arbitrary Waveform Generator User's Manual
Comprehensive user's manual for the FeelTech FY6600 series dual-channel function and arbitrary waveform generator, detailing features, operations, specifications, and troubleshooting for models like FY6600-60M.
Preview FeelTech FY3200S Series User's Manual: Dual Channel Function/Arbitrary Waveform Generator
Comprehensive user manual for the FeelTech FY3200S Series Dual Channel Function/Arbitrary Waveform Generator, detailing its features, operation, technical specifications, and safety guidelines.