1. Product Overview
The ALLmeter Non-Contact 2-in-1 Multimeter Tester Pen is a versatile electrical testing instrument designed for measuring AC/DC voltage, resistance, continuity, and diodes. It features a non-contact voltage (NCV) function for enhanced safety and an automatic range selection for ease of use. This compact device is suitable for various applications, including home electrical work, automotive diagnostics, and educational purposes.

Image 1.1: The ALLmeter Multimeter Tester Pen highlighting its diverse measurement capabilities including NCV, voltage, resistance, continuity, diode, and frequency.
2. Safety Information
Always adhere to safety precautions when using electrical testing equipment. Failure to do so may result in electric shock, injury, or damage to the device or property.
- Do not exceed the maximum input values specified for each measurement function.
- Ensure the test leads are in good condition, free from cracks or damage.
- Do not use the device if it appears damaged or is not operating correctly.
- Always disconnect power to the circuit before making resistance or continuity measurements.
- Use caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC, as these pose a shock hazard.
- When using the Non-Contact Voltage (NCV) function, remember it is an indicator and not a substitute for direct voltage measurement.
3. Setup
3.1. Unpacking and Inspection
Carefully remove the multimeter from its packaging. Inspect the device and accessories for any signs of damage. If any damage is found, do not use the device and contact customer support.
3.2. Battery Installation
The device requires two AAA batteries (included). To install or replace batteries:
- Locate the battery compartment cover on the back of the device.
- Use a small screwdriver to open the battery compartment.
- Insert two AAA batteries, ensuring correct polarity (+/-).
- Securely close the battery compartment cover.
3.3. Connecting Test Leads
The multimeter comes with a detachable test lead. The pen tip serves as the positive probe, while the black lead serves as the negative.
- Insert the black test lead into the 'Input COM' jack on the top of the multimeter.
- Ensure the connection is firm before use.

Image 3.1: Diagram showing the components of the ALLmeter Multimeter Tester Pen, including the Input COM port for the test lead, Select key, LCD display, NCV/LIVE key, HOLD key, LED light, and Test pen tip.

Image 3.2: The ALLmeter Multimeter Tester Pen shown with its detachable black test lead, ready for use.
4. Operating Instructions
4.1. Power On/Off
Press the red 'Select' button to power on the device. The device will automatically enter 'Auto' mode. To power off, press and hold the 'Select' button until the display turns off. The device also features an automatic shutdown after 15 minutes of inactivity to conserve battery life.
4.2. Automatic Function (Auto Mode)
In 'Auto' mode, the multimeter intelligently identifies and measures AC/DC voltage, resistance, and continuity without manual range selection. This mode simplifies common electrical tasks.

Image 4.1: Examples of the LCD display in automatic function mode, showing measurements for DC voltage, AC voltage, and resistance (Ohm).
4.3. Manual Function Selection
Press the 'Select' button repeatedly to cycle through manual measurement modes such as NCV, LIVE, Diode, and Frequency (Hz).

Image 4.2: Examples of the LCD display in manual function mode, showing indicators for NCV, LIVE wire detection, Diode testing, and Frequency measurement.
4.4. Non-Contact Voltage (NCV) Testing
The NCV function allows for safe detection of AC voltage without direct contact. This is ideal for identifying live wires in outlets, cables, or electrical panels.
- Press the 'NCV/LIVE' button to enter NCV mode. The display will show 'EF'.
- Bring the pen tip close to the object to be tested.
- An audible alarm and flashing LED light indicate the presence of AC voltage. The frequency of the alarm and light increases with stronger voltage signals.

Image 4.3: The multimeter pen demonstrating NCV detection on an electrical outlet and a cable, distinguishing between live and null wires with visual and audible alerts.
4.5. LIVE Wire Detection
The LIVE function helps distinguish between live and neutral wires in a circuit.
- Press the 'NCV/LIVE' button until 'LIVE' is displayed.
- Insert the pen tip into the terminal or touch the wire.
- A strong alarm and red light indicate a live wire. No alarm or a weaker signal indicates a neutral wire.

Image 4.4: The multimeter pen being used to detect a live wire within an electrical panel, with the display showing 'LIVE' and an illuminated tip.
4.6. Data Hold Function
Press the 'HOLD' button to freeze the current reading on the display. Press it again to release the hold function.
4.7. LED Flashlight
Press the 'LED Light' button to turn on the integrated flashlight for illumination in dimly lit areas. Press again to turn it off.
4.8. Product Video Demonstration
Watch this video for a visual guide on the functions and operation of the ALLmeter Multimeter Tester Pen.
Video 4.1: A demonstration of the ALLmeter 2-in-1 Pen Type Multimeter, showcasing its automatic function for measuring DC voltage, resistance, and diode, as well as its NCV and LIVE wire detection capabilities.
5. Maintenance
Proper maintenance ensures the longevity and accuracy of your multimeter.
- Cleaning: Wipe the device with a dry, soft cloth. Do not use abrasive cleaners or solvents.
- Storage: Store the multimeter in a cool, dry place away from direct sunlight and extreme temperatures. If storing for an extended period, remove the batteries to prevent leakage.
- Battery Replacement: Replace batteries promptly when the low battery indicator appears on the display to ensure accurate readings.
6. Troubleshooting
If you encounter issues with your ALLmeter Multimeter Tester Pen, refer to the following common troubleshooting steps:
- Device does not power on: Check if the batteries are correctly installed and have sufficient charge. Replace batteries if necessary.
- Inaccurate readings: Ensure the test leads are securely connected. Verify that the correct measurement mode is selected for manual functions. Check battery level.
- NCV/LIVE function not responding: Ensure the device is in the correct NCV or LIVE mode. The NCV function may be affected by external factors such as shielded wires or thick insulation.
- Display issues: If the display is dim or incomplete, replace the batteries.
For persistent issues, contact ALLmeter customer support.
7. Specifications
| Feature | Value |
|---|---|
| Product Dimensions | 2.44 x 1.22 x 7.36 inches |
| Item Model Number | ALLWT484-DEFBA |
| Batteries | 2 AAA batteries required (included) |
| Manufacturer | ALLmeter |
| Power Source | Battery Powered |
| Style | Voltage Tester Pen Type Multimeter |
| Color | Black |
| Item Weight | 60 Grams (2.12 ounces) |
7.1. Measurement Ranges
| Measurement | Range | Accuracy | Resolution |
|---|---|---|---|
| DC/AC Voltage (DCV/ACV) | 6V, 60V, 600V | ± (0.5%+3) | 0.001V, 0.01V, 0.1V |
| Resistance (Ω) | 600Ω, 6KΩ, 60KΩ, 600KΩ, 6MΩ, 60MΩ | ± (0.8%+5) (for 600Ω, 6KΩ, 60KΩ, 600KΩ) ± (1.2%+3) (for 6MΩ) ± (2.5%+3) (for 60MΩ) | 0.1Ω, 1Ω, 10Ω, 100Ω, 1KΩ, 10KΩ |
| Frequency (Hz) | 10-10M HZ | ± (2.0%+3) | 0.1 HZ |
8. What's in the Box
The product package includes:
- 1 x ALLmeter Multimeter Tester Pen
- 2 x 1.5V AAA Batteries
- 1 x Test Lead
9. Warranty and Support
For warranty information or technical support, please refer to the official ALLmeter website or contact their customer service department. Keep your purchase receipt for warranty claims.