MOBYAT AX260-30-11 3-Pole Contactor Instruction Manual

Model: AX260-30-11

1. Introduction

This instruction manual provides essential information for the safe and effective installation, operation, and maintenance of the MOBYAT AX260-30-11 3-Pole Contactor. Please read this manual thoroughly before attempting any procedures to ensure proper functionality and to prevent potential hazards.

2. Product Overview

The MOBYAT AX260-30-11 is a robust 3-pole contactor designed for controlling electrical circuits, particularly in industrial applications. It features a main contact configuration of 3 normally open (NO) poles and includes one normally closed (NC) and one normally open (NO) auxiliary contact for signaling or interlocking purposes. This contactor is suitable for use with both 50Hz and 60Hz power systems and supports a wide range of control voltages from 24V to 440V.

Front view of the MOBYAT AX260-30-11 3-Pole Contactor with detailed specifications label.

Figure 1: Front view of the MOBYAT AX260-30-11 Contactor, showing main power terminals (1 L1, 3 L2, 5 L3, 2 T1, 4 T2, 6 T3) and the product label with electrical ratings.

Side view of the MOBYAT AX260-30-11 Contactor, highlighting the auxiliary contact block CAL19-11.

Figure 2: Side view of the contactor, illustrating the mounted auxiliary contact block (CAL19-11) and its serial number.

Top view of the MOBYAT AX260-30-11 Contactor.

Figure 3: Top view of the contactor, showing the robust housing and mounting points.

3. Specifications

The following table details the technical specifications of the MOBYAT AX260-30-11 Contactor:

ParameterValue
ModelAX260-30-11
Number of Poles3-Pole
Auxiliary Contacts1 Normally Closed (NC) & 1 Normally Open (NO)
Rated Operational Current (AC-3)260A
Rated Operational Current (AC-1)400A
Rated Insulation Voltage (Ui)1000V
Rated Impulse Withstand Voltage (Uimp)8kV
Coil Voltage Range24V ~ 440V AC
Frequency50Hz / 60Hz
Thermal Current (Ith)400A
Power Rating (AC-3, 220-240V)80 kW
Power Rating (AC-3, 380-415V)140 kW
Power Rating (AC-3, 660-690V)200 kW
Power Rating (AC-3, 1000V)220 kW
HP Rating (3-Phase, 200-208V)75 HP
HP Rating (3-Phase, 220-240V)100 HP
HP Rating (3-Phase, 440-480V)200 HP
HP Rating (3-Phase, 550-600V)250 HP
General Purpose (600V AC)350A
Hermetic Refrigeration Compressor (600V)FLA 300, LRA 1800
Dimensions (Package)1.18 x 0.79 x 0.39 inches
Weight1.76 ounces
ManufacturerMOBYAT
Number of Pieces1

4. Safety Information

WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel.

  • Always disconnect power before installing, servicing, or removing the contactor.
  • Ensure all wiring complies with local and national electrical codes.
  • Use appropriate personal protective equipment (PPE) when working with electrical systems.
  • Verify that the contactor's ratings match the application requirements.
  • Do not operate the contactor if it appears damaged.

5. Setup and Installation

Proper installation is crucial for the safe and reliable operation of the contactor.

5.1 Mounting

  1. Select a suitable mounting location that is free from excessive vibration, moisture, and corrosive atmospheres.
  2. Ensure adequate ventilation around the contactor to prevent overheating.
  3. Mount the contactor securely using appropriate fasteners through the designated mounting holes.

5.2 Wiring

Before wiring, ensure all power sources are disconnected and locked out.

  1. Connect the main power supply lines to terminals 1 L1, 3 L2, and 5 L3.
  2. Connect the load lines to terminals 2 T1, 4 T2, and 6 T3.
  3. Connect the control circuit wires to the coil terminals (A1 and A2). The specific voltage for the coil is indicated on the contactor label.
  4. Utilize the auxiliary contacts (1NC & 1NO) as required for control logic, interlocking, or signaling. Refer to the wiring diagram on the contactor for terminal identification.
  5. Ensure all terminal screws are tightened to the manufacturer's specified torque to prevent loose connections and arcing.
Top-down view of the MOBYAT AX260-30-11 Contactor showing the main power terminals and coil connections A1 and A2.

Figure 4: Top-down view of the contactor, highlighting the main power terminals and the coil connection points (A1, A2).

Close-up view of the terminal connections on the MOBYAT AX260-30-11 Contactor.

Figure 5: Close-up of the terminal connections, showing the screw terminals for secure wiring.

6. Operating Instructions

The MOBYAT AX260-30-11 Contactor operates by energizing its coil, which causes the main contacts to close, thereby connecting the power supply to the load. When the coil is de-energized, the contacts open, disconnecting the load.

  1. After installation and verification of all wiring, apply control voltage to the coil terminals (A1 and A2).
  2. The contactor will audibly click as the main contacts close.
  3. To de-energize the load, remove the control voltage from the coil. The contactor will click again as the contacts open.
  4. Monitor the contactor during initial operation to ensure proper functioning and absence of abnormal noise or heating.

7. Maintenance

Regular inspection and maintenance can extend the lifespan of the contactor and ensure safe operation.

7.1 Routine Checks (Perform with power disconnected)

  • Inspect for any signs of physical damage, such as cracks, discoloration, or loose parts.
  • Check all terminal connections for tightness. Retighten if necessary.
  • Clean any dust or debris from the contactor's exterior using a dry, non-conductive cloth or compressed air.
  • Verify that the moving parts operate smoothly without obstruction.

7.2 Contact Inspection (Perform with power disconnected)

While the contactor is designed for durability, excessive arcing or frequent operation under heavy loads can cause contact wear. If possible, inspect the main contacts for pitting or erosion. Severely worn contacts should prompt replacement of the contactor.

8. Troubleshooting

This section provides guidance for common issues. For complex problems, consult a qualified electrician.

ProblemPossible CauseSolution
Contactor does not energize (no click)No control voltage to coil (A1/A2)
Incorrect coil voltage
Damaged coil
Loose wiring connection
Check control circuit power supply.
Verify coil voltage matches supply.
Test coil resistance; replace contactor if open.
Tighten all control wiring.
Contactor energizes but load does not receive powerNo main power supply
Loose main power connections
Damaged main contacts
Check main power supply.
Tighten main power wiring (L1, L2, L3, T1, T2, T3).
Inspect contacts; replace contactor if severely damaged.
Contactor hums excessively or overheatsIncorrect coil voltage
Loose connections
Contactor operating beyond ratings
Foreign material in magnet system
Verify coil voltage.
Check and tighten all connections.
Ensure load current is within specifications.
Inspect and clean the magnet system (power off).
Contactor fails to de-energizeControl voltage not removed
Welded contacts
Mechanical obstruction
Check control circuit for continuous voltage.
Replace contactor.
Inspect for debris or damage preventing contact opening.

9. Warranty and Support

The MOBYAT AX260-30-11 Contactor is provided without an explicit warranty. For technical support or inquiries, please contact your supplier or the manufacturer, MOBYAT.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.