Rebel RB-4012

Rebel POWER-800 RB-4012 Pure Sine Wave Inverter

User Manual

Introduction

Thank you for choosing the Rebel POWER-800 RB-4012 Pure Sine Wave Inverter. This device is designed to convert 12V DC power from a battery into 230V AC pure sine wave power, suitable for a wide range of electronic appliances. It also features an integrated charging function, allowing it to act as an emergency power supply. Please read this manual thoroughly before installation and operation to ensure safe and efficient use of your inverter.

Safety Instructions

Product Overview

Familiarize yourself with the components of your Rebel POWER-800 RB-4012 inverter.

Front view of Rebel POWER-800 RB-4012 Pure Sine Wave Inverter

Figure 1: Front Panel
This image shows the front of the Rebel POWER-800 inverter, featuring the digital LED display, two AC output sockets, and the DC input cables (red and black) for battery connection. The display provides real-time status information.

Rear view of Rebel POWER-800 RB-4012 Pure Sine Wave Inverter

Figure 2: Rear Panel
This image displays the rear of the Rebel POWER-800 inverter. It includes a cooling fan for heat dissipation, two AC output sockets, the AC input port for grid connection, and a circuit breaker for protection.

Specifications

FeatureSpecification
Rated Power500 W
Battery Type12 V DC
Maximum Battery Voltage15 V DC
Input Voltage Range (AC)180 ~ 275 V AC
Input Frequency45 ~ 60 Hz
Output Voltage Range (AC)230 V AC +/-8%
Output Frequency50/60 Hz +/-0.5 Hz
Output WaveformPure Sine Wave
Output Efficiency (DC to AC)>= 85%
Battery Charging CurrentMax. 10 A
Switching Time<= 4 ms
Protection FeaturesOverload, Short Circuit, Overvoltage, Undervoltage, Overheating
Operating Temperature0-40 °C
Humidity10-90%
Dimensions (L x W x H)215 x 265 x 100 mm
Weight4.7 kg

Setup

  1. Battery Connection: Connect the red DC cable from the inverter to the positive (+) terminal of your 12V battery. Connect the black DC cable to the negative (-) terminal. Ensure connections are tight and secure. Incorrect polarity will damage the unit.
  2. AC Input (Grid Connection): If you intend to use the charging function or have the inverter act as an emergency power supply, connect the AC input cable to a standard 230V AC wall outlet.
  3. AC Output (Device Connection): Plug your 230V AC appliances into the output sockets on the inverter's front or rear panel. Ensure the total power consumption of connected devices does not exceed the inverter's rated power of 500W.
  4. Placement: Place the inverter on a stable, flat surface in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure there is adequate space around the cooling fan.

Operating Instructions

  1. Power On: After all connections are made, switch on the inverter. The LED display will illuminate, showing the current status, including input voltage, output voltage, and battery charge level.
  2. Monitoring the Display: The LED display provides real-time information. Monitor it for battery status, AC input/output voltage, and any error indicators.
  3. Charging Function: When the inverter is connected to both a battery and an AC grid source, it will automatically charge the connected 12V battery. The display will indicate the charging status.
  4. Emergency Power Supply: In case of a power outage (loss of AC grid input), the inverter will automatically switch to battery power, providing continuous 230V AC output to connected devices within 4ms.
  5. Power Off: To turn off the inverter, first disconnect all AC appliances, then switch off the inverter, and finally disconnect the AC input cable (if connected) and battery cables.

Maintenance

Troubleshooting

ProblemPossible CauseSolution
No power outputBattery not connected or low voltage; Inverter switched off; Blown fuse/circuit breaker.Check battery connections and charge level; Ensure inverter is switched on; Reset circuit breaker or check internal fuse (if accessible and safe).
Overload warningConnected appliances exceed 500W rated power.Reduce the load by disconnecting some appliances.
Overheating warningPoor ventilation; Excessive load.Ensure adequate airflow around the inverter; Reduce load. Allow unit to cool down.
Short circuit protection activatedShort circuit in connected appliance or wiring.Disconnect all appliances and check for faulty wiring or devices. Reconnect one by one to identify the faulty item.
Battery not chargingAC input not connected; AC input voltage too low/high; Faulty battery.Ensure AC input cable is securely connected to a live outlet; Check AC input voltage; Test battery condition.

Warranty and Support

Rebel products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or contact your retailer. Keep your purchase receipt as proof of purchase.

Related Documents - RB-4012

Preview Manual de Utilizare Rebel RB-4026, RB-4027, RB-4028 - Invertor de Putere
Ghid complet pentru utilizarea, instalarea și întreținerea invertorului de putere Rebel cu undă sinusoidală pură și funcție de încărcare. Include instrucțiuni de siguranță, selecția bateriei și specificații tehnice.
Preview Rebel UPS Uninterruptible Power Supply User Manual RB-4020-5
User manual for Rebel Uninterruptible Power Supply (UPS) models RB-4020, RB-4021, RB-4022, RB-4023, RB-4024, RB-4025. Includes safety warnings, introduction, specifications, troubleshooting, and proper disposal information.
Preview Rebel Digital Multimeter MIE-RB-33B, C, D User Manual
User manual for the Rebel Digital Multimeter models MIE-RB-33B, MIE-RB-33C, and MIE-RB-33D. Includes safety instructions, product description, operation guide, specifications, and maintenance information.
Preview Rebel RB-1003 Cordless Screwdriver User Manual
Get detailed instructions and safety information for the Rebel RB-1003 Cordless Screwdriver. This user manual covers operation, maintenance, and troubleshooting for your Rebel tools.
Preview Rebel Power Inverter User Manual
Comprehensive user manual for Rebel Power Inverters, covering installation, operation, safety, troubleshooting, and specifications for models URZ3160-62, URZ3164-65, URZ3167-68.
Preview Rebel MIE-RB-55 Digital Multimeter User Manual
Comprehensive user manual for the Rebel MIE-RB-55 Digital Multimeter, covering safety instructions, product description, operation, maintenance, and technical specifications.