1. Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of your Ledvion LED TL Fixture. This product is a highly efficient and durable lighting solution, featuring natural daylight (4000K) and advanced integrated sensor technologies for effortless illumination. Please read this manual carefully before installation and retain it for future reference.
2. Safety Information
Always observe the following safety precautions to prevent injury or damage to the product:
- Electrical Safety: Installation must be performed by a qualified electrician in accordance with local electrical codes and regulations. Ensure the power supply is disconnected before any installation, maintenance, or repair work.
- Voltage: This fixture operates on 220-240 Volts at 60 Hertz. Verify your power supply matches these requirements.
- IP65 Rating: The fixture is rated IP65, meaning it is protected against dust ingress and low-pressure water jets from any direction. This makes it suitable for both indoor and outdoor use, including environments like garages, warehouses, workshops, and parking areas. However, it is not designed for submersion.
- Heat: Do not cover the fixture during operation, as this may lead to overheating.
- Damage: Do not use the fixture if any part is damaged. Contact Ledvion support for replacement parts or service.

3. What's in the Box
Verify that all components are present before beginning installation:

- 6x LED Batten (150cm, 36W, 4000K)
- 12x Endcap
- 12x Suspension set
- 6x Plug
- 12x Screws
- 12x Screw wall plugs
- 1x Manual
4. Installation
4.1 Mounting the Fixture
- Choose a suitable mounting location, ensuring it can support the weight of the fixture(s).
- Mark the positions for the suspension set brackets on the ceiling or wall.
- Drill holes at the marked positions and insert the screw wall plugs.
- Secure the suspension set brackets using the provided screws.
- Attach the LED TL fixture to the mounted suspension set.
4.2 Electrical Connection
- Ensure the main power supply is OFF before proceeding.
- Open the wiring compartment at one end of the fixture.
- Connect the live (L), neutral (N), and ground (PE) wires from your power supply to the corresponding terminals inside the fixture. Refer to the wiring diagram if provided with the product.
- Close the wiring compartment securely to maintain the IP65 rating.
4.3 Linking Multiple Fixtures
The Ledvion LED TL fixtures are designed to be toollessly linkable, allowing you to connect up to 20 pieces in a series. This feature simplifies installation for longer runs of lighting.

- Ensure power is disconnected.
- Align the linking connector of the second fixture with the output connector of the first fixture.
- Push the fixtures together until they click securely into place.
- Repeat for additional fixtures, up to a maximum of 20 units.
4.4 Sensor Configuration (Motion & Daylight)
This fixture includes an integrated motion sensor and a daylight sensor for automatic operation.
- Motion Sensor: The adjustable motion sensor has a detection range of 4 to 10 meters. It accurately detects movement within this area and automatically switches on the LED fixture when needed.
- Daylight Sensor: The daylight sensor features an automatic on/off function based on ambient light levels. If there is sufficient daylight, the light remains off. If daylight is insufficient and motion is detected, the light will switch on.
- Adjustments: Specific adjustments for sensitivity and duration may be available via internal dip switches or a dedicated control method (e.g., app control as mentioned in specifications). Refer to the detailed sensor manual if provided separately.
5. Operation
Once installed and powered, the Ledvion LED TL fixture operates automatically based on its integrated sensors:
- The fixture will illuminate when motion is detected in an area with insufficient natural light.
- It will turn off after a set period of no motion, or when sufficient natural light is present.
- The light output is a natural daylight white (4000K) with a brightness of 6400 lumens, providing clear and efficient illumination.


6. Maintenance
The Ledvion LED TL fixture is designed for long-term, low-maintenance operation. It features high-performance Samsung LED chips with an expected lifetime of 50,000 hours.
- Cleaning: Due to its IP65 rating, the fixture can be cleaned with a damp cloth. Do not use abrasive cleaners or solvents. Ensure the power is off before cleaning.
- Repair: The unit is sealed and not designed for user repair. In case of malfunction, contact Ledvion support.
7. Troubleshooting
If you encounter issues with your Ledvion LED TL fixture, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Fixture does not turn on. | No power supply; incorrect wiring; daylight sensor active; motion sensor not triggered. | Check power connection; verify wiring; ensure ambient light is low enough; trigger motion sensor. |
| Fixture stays on continuously. | Continuous motion detected; sensor settings incorrect. | Ensure no constant motion in detection zone; adjust sensor settings (if applicable). |
| Fixture flickers. | Unstable power supply; faulty fixture. | Check power source stability; contact support if problem persists. |
| Sensor range is too short/long. | Sensor sensitivity settings. | Adjust sensor sensitivity (if applicable, refer to sensor manual). |
If the problem persists after attempting these solutions, please contact Ledvion customer support.
8. Technical Specifications
| Feature | Specification |
|---|---|
| Brand | Ledvion |
| Model Number | LV40014-6pack |
| Light Type | LED |
| Special Features | Motion Sensor, Daylight Sensor |
| Wattage | 36W (per fixture, product title) / 48W (from specifications, likely total for a set or max) |
| Equivalent Incandescence | 96 Watt |
| Light Color | Natural Daylight White (4000K) |
| Voltage | 230 Volt (220-240V) |
| Luminous Flux | 6400 lm |
| Usage Environment | Indoor/Outdoor (IP65 rated) |
| Power Source | Electric |
| Control Method | App (as per specifications, for sensor adjustments) |
| Energy Efficiency Class | E |
| Shape | Tubular (T) |
| Material | Plastic |
| Certification Standard | IP65 |
| Product Weight | 6180 Grams (for the 6-pack) |
| Dimensions (approx.) | 1500 mm (Length) x 63.2 mm (Diameter) |
| LED Chip Lifetime | 50,000 hours |


9. Warranty and Support
Ledvion products are manufactured to high-quality standards. For information regarding warranty terms and conditions, please refer to the documentation provided at the time of purchase or contact your retailer. If you require technical assistance or have questions not covered in this manual, please contact Ledvion customer support or the seller directly.