1. Important Safety Instructions
Please read all instructions carefully before operating the dehumidifier. Failure to follow these instructions may result in electric shock, fire, property damage, or personal injury.
- Always connect the unit to a properly grounded electrical outlet.
- Do not operate the unit with a damaged power cord or plug. If the power cord is damaged, it must be replaced by the manufacturer or a qualified service agent.
- Ensure the unit is placed on a level, stable surface to prevent tipping.
- Maintain at least 12 inches (30 cm) of clearance around all sides of the unit for proper airflow.
- Do not insert fingers or foreign objects into the air inlet or outlet.
- Keep children and pets away from the unit during operation.
- Unplug the dehumidifier before cleaning, performing maintenance, or moving it.
- Do not use the unit in areas where flammable gases or liquids are stored.
2. Product Overview
The ANDTE 190 Pints Industrial Dehumidifier is designed for efficient moisture removal in large spaces such as basements, warehouses, and job sites. It features a robust design with a built-in pump for continuous drainage.

Image: Front-side view of the ANDTE 190 Pints Industrial Dehumidifier, showcasing its blue and gray casing, handle, and wheels.
Key Components
- Control Panel: For setting humidity, timer, and power.
- Air Inlet/Outlet: Where air enters and exits the unit.
- Drain Port: For connecting the drain hose.
- Heavy-Duty Wheels: For easy mobility.
- Sturdy Bar Handle: For convenient transport.

Image: Detailed view of the dehumidifier's components, including the sturdy bar handle, 16.5 ft water hose, 10 ft power cord, and two 12-inch rubber wheels, highlighting its portability.
3. Setup and Installation
Unpacking
- Carefully remove the dehumidifier from its packaging.
- Inspect the unit for any shipping damage. If damaged, contact customer support immediately.
- Remove all packing materials and ensure no components are left inside the unit.
Positioning the Unit
- Place the dehumidifier on a firm, level surface capable of supporting its weight.
- Ensure there is at least 12 inches (30 cm) of clear space around the air inlet and outlet for optimal performance.
- Avoid placing the unit near heat sources or in direct sunlight.
Drainage Setup (Built-in Pump)
The unit features a built-in heavy-duty pump for continuous drainage, allowing water to be discharged vertically up to 15 feet.
- Locate the drain port on the unit.
- Connect the provided 16.5 ft drain hose securely to the drain port.
- Route the other end of the drain hose to a suitable drainage location, such as a sink, floor drain, or outside. Ensure the hose is not kinked or obstructed.

Image: Illustration of the built-in pump system, demonstrating how the 16.5 ft drain hose can be routed to drain water vertically, for example, out of a window.
Power Connection
- Plug the power cord into a grounded 120V/60Hz electrical outlet.
- Ensure the outlet meets the electrical requirements of the unit.
4. Operation
Control Panel Overview
The control panel provides access to all operational settings. It includes a humidity display, indicator lights, and function buttons.

Image: Close-up of the intuitive control panel, showing the digital humidity display, indicator lights for defrost, pump, and running status, and clearly labeled buttons for various functions.
- POWER Button: Turns the unit ON/OFF.
- UP/DOWN Buttons: Adjust the desired humidity level (10%-98% RH) or timer settings.
- TIMER Button: Sets the 24-hour timer for automatic ON/OFF operation.
- PUMP Button: Activates or deactivates the built-in pump for continuous drainage.
- Display Screen: Shows real-time humidity and other settings.
- Indicator Lights: Indicate operational status (e.g., Defrost, Pump, Running).
Initial Startup and Humidity Setting
- Press the POWER button to turn on the unit. The display will show the current room humidity.
- Use the UP or DOWN buttons to set your desired humidity level. The unit will operate until the set humidity is reached, then cycle off. It will restart automatically if humidity rises above the set level.
- For continuous operation, set the humidity to the lowest possible value (e.g., 10% RH).
Timer Function
The 24-hour timer allows you to schedule the unit to turn ON or OFF automatically.
- To set Auto-OFF: While the unit is running, press the TIMER button. Use UP/DOWN to select the desired number of hours (1-24) after which the unit will turn off.
- To set Auto-ON: While the unit is off, press the TIMER button. Use UP/DOWN to select the desired number of hours (1-24) after which the unit will turn on.
Auto Defrost Function
The unit is equipped with an automatic defrost function to ensure continuous operation in low-temperature environments (recommended working temperature range: 41℉-104℉).
- If frost builds up on the evaporator coils, the unit will automatically enter defrost mode. The compressor will shut down, but the fan will continue to run.
- The 'DEFROST' indicator light will illuminate.
- Once defrosting is complete, the unit will automatically resume normal dehumidification operation.

Image: Visual representation of the auto defrost cycle. The left panel shows evaporator coils covered in frost, indicating the compressor is off and the fan is running. The right panel shows clear coils after defrost, with the compressor restarting and the fan running normally.
5. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your dehumidifier. Always unplug the unit before performing any maintenance.
Cleaning the Air Filter
The high-density air filter should be cleaned every 2-3 months, or more frequently depending on usage and air quality.
- Turn off and unplug the dehumidifier.
- Locate and remove the air filter from the unit (typically on the back or side).
- Wash the filter with warm, soapy water. Rinse thoroughly.
- Allow the filter to air dry completely before reinstalling it. Do not use a dryer or direct heat.
- Reinsert the dry filter into the unit.

Image: Illustration demonstrating the removal and cleaning process for the washable high-density filter, emphasizing the importance of regular maintenance.
Cleaning the Unit Exterior
- Wipe the exterior of the unit with a soft, damp cloth.
- Do not use harsh chemicals, abrasives, or solvents, as these can damage the surface.
Long-Term Storage
- If storing the unit for an extended period, ensure the drain hose is empty and clean.
- Clean the air filter and the exterior of the unit.
- Store the dehumidifier in a dry, upright position in a safe location.
6. Troubleshooting
Before contacting customer support, please refer to the following troubleshooting guide for common issues.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on | No power supply Power cord not plugged in Circuit breaker tripped | Check power outlet Ensure power cord is securely plugged in Reset circuit breaker |
| No dehumidification or insufficient dehumidification | Air filter clogged Room temperature too low Humidity setting too high Doors/windows open | Clean air filter Ensure room temperature is within 41℉-104℉ Lower the desired humidity setting Close all doors and windows |
| Unit is noisy | Unit not on a level surface Air filter clogged | Place unit on a level surface Clean air filter |
| Water leakage | Drain hose not connected properly Drain hose kinked or blocked | Ensure drain hose is securely attached Check and clear any obstructions in the drain hose |
| "EP" Error Code | Pump malfunction or blockage | Check drain hose for kinks or blockages. Ensure pump is clear of debris. If problem persists, contact customer support. |
7. Specifications
Technical specifications for the ANDTE 190 Pints Industrial Dehumidifier.

Image: The dehumidifier displayed alongside a detailed list of its technical specifications, including moisture removal capacity, power, and dimensions.
| Feature | Specification |
|---|---|
| Brand | ANDTE |
| Model Name | 190 Pints |
| Dehumidification Capacity (90℉/90% RH) | 190 Pints per Day |
| Dehumidification Capacity (80℉/60% RH) | 90 Pints per Day |
| Floor Area Coverage | Up to 3500 Square Feet |
| Humidity Setting Range | 10% - 98% RH (±1%) |
| Voltage | 120 Volts / 60 Hz |
| Rated Power (90℉/90% RH) | 1150 Watts |
| Input Power (65℉/60% RH) | 610 Watts |
| Current (90℉/90% RH) | 10.3 Amps |
| Air Flow Capacity | 350 Cubic Feet Per Minute |
| Operation Mode | Continuous |
| Working Temperature Range | 41℉ - 104℉ (5℃ - 40℃) |
| Product Dimensions (D x W x H) | 17.5" x 17.7" x 32.2" |
| Item Weight | 88 pounds |
| Drain Hose Length | 16.5 ft |
| Special Features | Built-In Pump, Memory Restart, Auto Defrost, 24 Hrs Timer |
| Material | Polyethylene (PE) |
8. Warranty and Customer Support
ANDTE provides comprehensive warranty coverage and dedicated customer support for your dehumidifier.

Image: A table outlining the ANDTE Warranty Services Policy, specifying coverage duration and solutions for various components.
Warranty Coverage
All warranty periods begin from the day following delivery.
- Refrigeration System: 5 Years (Compressor, Condenser, Evaporator ONLY. Excludes labor and refrigerant).
- Electronic Components: 3 Years (Display screen, Mainboard, Signal cable, etc. Excludes labor).
- Consumable Accessories: 1 Year (Drain hose, Filter, Handle, Screws, etc. Excludes labor).
- Overall Unit (Functional Failure/Defect): 1 Year (Excludes labor).
- Overall Unit (Nonfunctional Problem): 30 Days (Does not cover artificial damage or loss of products/components not complying with the 30-day return policy).
Customer Support
For any questions, technical assistance, or warranty claims, please contact ANDTE customer support. Our professional customer support team will assist you and reply to your email within 24 hours.
Please refer to your product packaging or the official ANDTE website for the most current contact information.