HOCANFLO HO FLO500

HOCANFLO 500W Macerator Pump Instruction Manual

Model: HO FLO500

Product Overview

The HOCANFLO 500W Macerator Pump with Impeller Blades is designed for efficient sewerage and water disposal in various applications, including bathrooms, sinks, and basements. It features automatic start and stop functionality and a reamer crush function for effective waste processing. This versatile pump provides a solution for installing plumbing fixtures where connection to a main sewer line is challenging.

HOCANFLO 500W Macerator Pump

Figure 1: HOCANFLO 500W Macerator Pump, front view.

Key Features

  • 500W Macerator Pump with Impeller Blades for efficient waste processing.
  • 3 Connections for Bathroom, Sink, and Basement water disposal.
  • Automatic Start and Stop functionality.
  • Reamer Crush Function for effective sewage treatment.
  • Low power consumption with high power output compared to similar 500W models.
  • Maximum flow of 1580 GPH.
  • Inlet Diameter: 1-1/2"; Outlet Diameter: 1", 1-1/4" and 1-1/2".
  • Long-life electric motor with copper wires and stainless steel non-clog blades.
  • Vertical pumping up to 30 feet and horizontal pumping up to 260 feet (depending on pipe diameter).

Specifications

AttributeValue
BrandHOCANFLO
ModelHO FLO500
Power SourceCorded Electric
Power500W
MaterialStainless Steel (blades)
Maximum Lifting Height30 Feet (vertical)
Maximum Horizontal Distance260 Feet
Maximum Flow1580 GPH
Item Weight15.42 pounds
Package Dimensions19 x 15.5 x 7.75 inches
HOCANFLO Macerator Pump Dimensions

Figure 2: Key dimensions of the HOCANFLO Macerator Pump.

HOCANFLO Macerator Pump Performance Metrics

Figure 3: Performance metrics including noise level, flow rate, and pumping distances.

Setup and Installation

Proper installation is crucial for the optimal performance and longevity of your HOCANFLO Macerator Pump. Please follow these steps carefully. For a visual guide, refer to the installation video below.

1. Unboxing and Component Identification

Before beginning installation, ensure all components are present and undamaged. Familiarize yourself with the pump's various inlets and outlets.

HOCANFLO Macerator Pump Labeled Inlets and Outlets

Figure 4: Labeled diagram of the macerator pump showing water inlets, toilet inlet, outlet, and deodorization device.

HOCANFLO Macerator Pump Accessories

Figure 5: Included accessories for installation, such as various pipe connectors and clamps.

2. Connecting to the Toilet

The macerator pump is designed to connect directly to a P-trap toilet. Ensure the toilet's drainage port aligns with the pump's toilet inlet. Use the provided rubber ring and clamp to secure the connection firmly, preventing leaks.

HOCANFLO Macerator Pump connected to a toilet and sink

Figure 6: Diagram illustrating the macerator pump installed with a toilet and sink in a bathroom setting.

3. Connecting Additional Water Inlets

The pump features two additional water inlets at the bottom, suitable for connecting a shower, washbasin, or other greywater sources. Remove the plugs from these inlets and connect the appropriate hoses. Ensure all connections are secured with clamps.

HOCANFLO Macerator Pump connections for various fixtures

Figure 7: Overview of the macerator pump showing connections to a sink, toilet, shower room, and washing machine.

4. Outlet Pipe Installation

Install the outlet pipe from the top of the macerator pump. The elbow fitting can be connected to 28mm, 32mm, or 40mm PVC pipes. For optimal flow, ensure the pipe connecting to the water pump maintains at least a 3% inclination to allow sewage to enter smoothly. If the toilet is installed directly below the main sewage pipe, an elbow may not be necessary; simply remove the black check valve and fix it at the water outlet position. A ball valve can be installed near the top of the outlet pipe to prevent backflow during maintenance or repair.

5. Deodorization Device

The pump includes a vent for deodorization. An activated carbon bag can be placed inside this vent to neutralize odors. Replace the carbon bag periodically for best results.

Installation Video Guide

Video 1: Detailed guide on how to install the HOCANFLO 500Watt-B Macerator Pump. This video covers connecting the toilet, additional inlets, and the outlet pipe, including tips for ensuring proper flow and preventing backflow.

Video 2: Demonstration of the macerating pump's check valve functionality, showing how it prevents backflow in the system.

Operation

The HOCANFLO Macerator Pump operates automatically. Once connected to the toilet and other fixtures, it will activate when waste water enters the pump chamber, macerating solids and pumping the effluent through the discharge pipe. The automatic start and stop function ensures efficient operation only when needed.

Ensure the pump is always connected to a reliable power source. Avoid flushing non-biodegradable items, excessive amounts of toilet paper, or foreign objects, as this can damage the impeller blades and motor.

Maintenance

  • Regular Cleaning: Periodically inspect the pump and connections for any buildup or blockages. Disconnect power before any inspection or cleaning.
  • Deodorization: Replace the activated carbon bag in the vent as needed to maintain effective odor control. The frequency depends on usage.
  • Check for Leaks: Regularly check all pipe connections and clamps for any signs of leaks. Tighten clamps if necessary.
  • Avoid Harsh Chemicals: Do not use harsh chemical drain cleaners, as they can damage the pump's internal components.
  • Winterization (if applicable): If the pump is installed in an unheated area subject to freezing temperatures, ensure it is properly drained and winterized to prevent damage.

Troubleshooting

ProblemPossible CauseSolution
Pump not startingNo power; float switch stuck; motor issue.Check power supply. Inspect float switch for obstructions. Contact support if motor is faulty.
Pump running continuouslyFloat switch stuck in "on" position; continuous water inflow.Check float switch for obstructions. Ensure no continuous water source is feeding the pump.
Poor maceration or dischargeBlockage in impeller; incorrect pipe slope; check valve issue.Disconnect power and inspect impeller for foreign objects. Verify correct pipe inclination. Check check valve for proper operation.
OdorsActivated carbon bag needs replacement; poor ventilation.Replace activated carbon bag. Ensure proper ventilation in the installation area.

If troubleshooting steps do not resolve the issue, please contact HOCANFLO customer support.

Warranty and Customer Support

HOCANFLO is committed to delivering quality products and responsible service. This product comes with a 2-year warranty. If you have any queries or require assistance, please feel free to email us. We aim to respond within 12 hours.

For further support, visit the official HOCANFLO store: HOCANFLO Store

© 2024 HOCANFLO. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.