Introduction
This manual provides essential information for the installation, operation, and maintenance of your Jaspertronics Original Lamp & Housing for the Optoma W515 Projector. This product is designed to deliver original performance and ensure the continued optimal function of your projector. Please read this manual thoroughly before proceeding with installation or maintenance.
Safety Information
WARNING: Projector lamps operate at high temperatures and contain mercury. Handle with care and follow all safety precautions.
- Always disconnect the projector from the power source and allow it to cool completely (at least 30 minutes) before attempting to replace the lamp.
- Do not touch the bare lamp bulb with your fingers. Oils from your skin can cause hot spots and reduce lamp life.
- Wear protective gloves if possible.
- Dispose of old lamps according to local environmental regulations. Do not dispose of lamps in regular household waste.
- Ensure the lamp compartment cover is securely closed before reconnecting power to the projector.
What's in the Box
Your package should contain the following item:
- One (1) Jaspertronics Original Lamp & Housing for Optoma W515 Projector.

Image: The Jaspertronics Original Lamp & Housing unit, ready for installation.
Setup and Installation
Follow these general steps to replace the lamp in your Optoma W515 Projector. Refer to your projector's specific user manual for detailed instructions and safety warnings, as procedures may vary slightly by model.
- Power Off and Disconnect: Turn off the projector and unplug the power cord from the electrical outlet.
- Allow Cooling: Wait at least 30 minutes for the lamp to cool down completely. The lamp becomes extremely hot during operation.
- Locate Lamp Compartment: Identify the lamp compartment cover on your projector. This is typically secured by one or more screws.
- Remove Cover: Use a screwdriver to loosen the screw(s) holding the lamp cover in place. Carefully remove the cover.
- Unscrew Old Lamp: The old lamp module will be secured by one or more screws. Loosen these screws.
- Remove Old Lamp: Gently pull the handle on the lamp module to slide it out of the projector. Be careful not to drop it.
- Insert New Lamp: Carefully insert the new Jaspertronics lamp module into the projector, ensuring it slides smoothly into place until it is fully seated. Do not force it.
- Secure New Lamp: Tighten the screw(s) to secure the new lamp module in the projector.
- Replace Cover: Reattach the lamp compartment cover and tighten its screw(s). Ensure it is securely closed.
- Reconnect Power: Plug the projector's power cord back into the electrical outlet.
- Reset Lamp Timer: Consult your projector's manual for instructions on how to reset the lamp timer. This is crucial for accurate lamp life tracking.

Image: A hand carefully removing an old lamp module from a projector. Note the handle for easy extraction.

Image: Front view of the Jaspertronics lamp module, showing the bulb and housing structure.
Operating Instructions
The Jaspertronics lamp module is a replacement component for your Optoma W515 Projector. Its operation is entirely dependent on the projector itself. Please refer to your Optoma W515 Projector's original user manual for detailed operating instructions, including power on/off procedures, input selection, and image adjustments.
Maintenance
Proper maintenance can extend the life of your projector and the new lamp.
- Air Filter Cleaning: Regularly clean or replace the projector's air filter to ensure proper airflow and prevent overheating, which can shorten lamp life. Consult your projector's manual for filter location and cleaning instructions.
- Cool Down Period: Always allow the projector to complete its cool-down cycle before unplugging it or moving it. This protects the lamp from thermal shock.
- Avoid Frequent On/Off Cycles: Turning the projector on and off frequently can reduce lamp life.
- Storage: If storing the projector for an extended period, ensure it is in a cool, dry place.

Image: A hand demonstrating the removal or cleaning of a projector's air filter.
Troubleshooting
If you encounter issues after installing the new lamp, consider the following:
| Problem | Possible Cause | Solution |
|---|---|---|
| No image / Projector not turning on | Lamp not properly seated; Lamp compartment cover not closed; Power issue. | Ensure lamp is fully inserted and secured. Close lamp cover completely. Check power connections. |
| Dim image / Poor brightness | Lamp timer not reset; Projector settings. | Reset the lamp timer in the projector's menu. Check projector brightness settings. |
| Lamp indicator light on | Lamp timer needs reset; Lamp nearing end of life (if not reset). | Reset the lamp timer. If the issue persists after reset, consult projector manual for specific error codes. |
For further troubleshooting, refer to your Optoma W515 Projector's user manual or contact Jaspertronics customer support.
Specifications
- Product Type: Original Lamp & Housing Module
- Compatibility: Optoma W515 Projector (and other compatible models listed in product description)
- Model Number: W515-LAMP
- Weight: 15.8 ounces
- Manufacturer: Jaspertronics
Warranty and Support
Your Jaspertronics Original Lamp & Housing for the Optoma W515 Projector comes with a 1-Year Warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use.
For warranty claims, technical support, or any questions regarding your product, please contact Jaspertronics customer service. You can find contact information on the official Jaspertronics website or through your point of purchase.
Manufacturer: Jaspertronics
Seller: Jaspertronics, LLC





