Introduction

The ANCEL L100 PRO Smoke Machine is a professional automotive diagnostic tool designed to quickly and accurately identify leaks in various vehicle systems. Featuring a built-in air compressor, adjustable digital pressure gauge, and flow dial, this device ensures safe and precise leak detection for EVAP, vacuum, fuel, exhaust, and intake pipes. Its low 0.5 PSI output prevents damage to sensitive vehicle components, making it an essential tool for maintaining optimal vehicle performance and preventing costly repairs.

What's in the Box

The ANCEL L100 PRO Smoke Machine comes with all essential accessories for immediate use:

  • ANCEL L100 PRO Smoke Machine Unit
  • Power Cord with Battery Clamps
  • Delivery Hose
  • Hook for hanging the unit
  • Block-off Cap Set (23 pieces)
  • Funnel for smoke oil filling
  • Intake Bladder
  • Smoke Diffuser
  • EVAP Test Kit (includes adapter and removal tool)
  • Rubber Adapters
ANCEL L100 PRO Smoke Machine and included accessories

Image: ANCEL L100 PRO Smoke Machine with all components and accessories laid out.

Setup

Follow these steps to prepare your ANCEL L100 PRO for operation:

  1. Fill with Smoke Oil: Unscrew the oil filler cap on top of the unit. Use the provided funnel to pour approximately 20ml of smoke oil (mineral oil or baby oil) into the unit. Do not overfill; ensure the oil level is below the MAX line indicated by the sight glass.
    Step 1: Fill with smoke oil

    Image: Illustration of filling the smoke machine with oil using the funnel.

  2. Install Hook: Screw the hanging hook into the designated port on the top of the unit. This allows you to suspend the device during testing.
  3. Connect Hoses and Adapters: Attach the delivery hose to the smoke outlet port. Select the appropriate adapter or block-off cap for the system you intend to test and connect it to the delivery hose.
  4. Connect to Vehicle Power: Connect the red battery clamp to the positive (+) terminal of your vehicle's 12V battery and the black clamp to the negative (-) terminal. Ensure a secure connection.

Video: Official ANCEL L100 Pro Evap Smoke Machine setup and operation guide. This video demonstrates the steps for preparing the device for use, including filling with smoke oil, connecting power, and attaching hoses.

Operating Instructions

The ANCEL L100 PRO is designed for simple 4-step operation:

  1. Power On: Flip the power switch on the unit to the "ON" position. The digital display will illuminate, showing the current pressure reading.
    Digital pressure gauge display

    Image: Close-up of the digital pressure gauge, displaying real-time readings in various units (PSI, Bar, Kpa, Kg/cm²).

  2. Adjust Flow Control: Use the adjustable flow control knob to fine-tune the smoke output. For precise leak detection, especially in smaller systems, adjust the flow to a lower setting. For larger systems, a higher flow may be appropriate.
    Precision flow control dial

    Image: Diagram illustrating the precision flow control dial for adjusting smoke output volume.

  3. Inject Smoke: Direct the smoke diffuser or hose adapter into the system you are testing. The unit will begin generating smoke within 10 seconds.
    Smoke output from the device

    Image: The smoke machine actively producing smoke from the delivery hose and smoke diffuser.

  4. Inspect for Leaks: Observe the system for visible smoke escaping from any cracks, loose connections, or damaged components. The digital pressure gauge will also provide real-time feedback on pressure changes, indicating the presence and severity of a leak.
    10-second fast leak detection process

    Image: Visual representation of the 10-second fast leak detection process, showing smoke being used to identify leaks.

Applications

The ANCEL L100 PRO is versatile and can be used to diagnose leaks in a wide range of vehicle systems, including:

  • EVAP System: Detects leaks in the evaporative emission control system, which operates at low pressure. The L100 PRO's smart regulator safely maintains 0.5 PSI to prevent damage.
  • Vacuum Leaks: Identifies leaks in vacuum lines and components.
  • Fuel System: Pinpoints leaks in fuel lines, tanks, and related components.
  • Exhaust System: Detects leaks in exhaust pipes, manifolds, and mufflers.
  • Intake Pipes: Locates leaks in the engine's air intake system.
  • Crankcase System: Checks for leaks in the crankcase ventilation system.
  • Cooling System: Can be used to identify leaks in the cooling system.
  • Wind/Water Leaks: The smoke diffuser can help locate leaks around doors, windows, sunroofs, and trunk compartment seals.
Vehicle systems for leak detection

Image: Diagram illustrating various vehicle systems where the smoke machine can detect leaks, including EVAP, vacuum, crankcase, cooling, and intake systems.

Maintenance

Proper maintenance ensures the longevity and optimal performance of your ANCEL L100 PRO Smoke Machine:

  • Smoke Oil Level: Regularly check the smoke oil level using the sight glass. Refill when low, ensuring not to exceed the MAX line.
  • Cool-down Periods: The unit has a 5-minute maximum continuous run time. Allow the machine to cool down for 5 to 10 minutes after each cycle to prevent overheating and ensure consistent smoke production.
  • Storage: Store the unit in a dry, clean environment. Ensure all hoses and accessories are properly detached and stored to prevent damage.
  • Cleaning: Wipe down the exterior of the unit with a clean, damp cloth. Do not use harsh chemicals or abrasive cleaners.

Troubleshooting

If you encounter issues with your ANCEL L100 PRO, consider the following common solutions:

  • No Smoke Production:
    • Check smoke oil level; refill if too low.
    • Ensure the unit is not overfilled with smoke oil, as this can prevent smoke production.
    • Verify power connection to the vehicle battery.
    • Allow adequate cool-down time if the unit has been running continuously.
  • Inconsistent Smoke Output:
    • Adjust the flow control knob to a stable setting.
    • Check for kinks or blockages in the delivery hose.
    • Ensure the unit has sufficient smoke oil.
  • Digital Display Not Lighting Up:
    • Confirm proper connection to the 12V vehicle battery.
    • Check the power switch is in the "ON" position.

Specifications

FeatureDetail
BrandANCEL
ModelANCEL L100 PRO
Item Weight3.96 pounds
Package Dimensions10.2 x 9.92 x 6.85 inches
Country of OriginChina
Output Pressure0.5 PSI
Output Volume<8LPM
Power SupplyDC 12V
Current5AMP

Warranty and Support

For warranty information or technical support, please refer to the contact details provided in your product packaging or visit the official ANCEL website. Keep your purchase receipt for any warranty claims.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.