DERMALOGIC KGO-SAAPP-60

DERMALOGIC UV Ozone Heating Cabinet

Model: KGO-SAAPP-60

Brand: DERMALOGIC

1. Important Safety Information

This appliance is designed for professional spa and salon use. Read all instructions carefully before operation to ensure safe and effective use. Keep this manual for future reference.

  • Do not operate the unit if the power cord is damaged.
  • Ensure the unit is placed on a stable, heat-resistant surface.
  • Do not block ventilation openings.
  • Keep out of reach of children.
  • Always unplug the unit before cleaning or maintenance.
  • Avoid direct exposure to UV light.
  • The interior surfaces can become hot during operation. Use caution when opening the door and handling sterilized items.
Warning label inside the sterilizer indicating 'HOT SURFACE DO NOT TOUCH'

Image: Interior warning label indicating 'HOT SURFACE DO NOT TOUCH' and caution against placing items on the exhaust cover.

2. Product Overview

The DERMALOGIC KGO-SAAPP-60 is a professional instrument and towel sterilizer designed for spa, salon, and tattoo studio use. It combines UV sterilization, ozone sanitization, and heating functions to ensure thorough disinfection of various tools and towels.

Key Features:

  • 60L Capacity for instruments and towels.
  • UV Sanitization and Ozone Sterilization.
  • Heating Function: Heats up to 140°F (60°C).
  • Two UV Light Ultraviolet Lamps (10W each, EPA No.102999-CHN-1).
  • Touch Control Buttons: Power, UVC, UVC+Heat, Auto.
  • Automatic Shut-off System: Activates when the door is opened.
  • Auto Function: Cycles sterilization process every 3 hours when powered.
  • Durable Stainless Steel construction.
Front view of the DERMALOGIC UV Ozone Heating Cabinet, closed.

Image: Front view of the DERMALOGIC KGO-SAAPP-60 UV Ozone Heating Cabinet with the door closed.

Interior view of the DERMALOGIC UV Ozone Heating Cabinet with the door open, showing multiple racks.

Image: Interior view of the cabinet with the door open, revealing multiple stainless steel racks for holding items.

Close-up of the UV lamps inside the sterilizer, emitting blue light.

Image: Close-up of the two UV germicidal lamps installed inside the cabinet, emitting a blue light.

3. Setup

  1. Unpacking: Carefully remove the sterilizer from its packaging. Inspect for any damage during transit.
  2. Placement: Place the unit on a flat, stable, and heat-resistant surface. Ensure there is adequate ventilation around the unit, especially at the rear and sides.
  3. Power Connection: Connect the power cord to the unit's power inlet and then plug it into a grounded electrical outlet (110V, 50-60Hz).
  4. Initial Cleaning: Before first use, wipe the interior and exterior surfaces with a damp cloth. Ensure the unit is completely dry before plugging it in.
Rear view of the DERMALOGIC UV Ozone Heating Cabinet showing the power inlet and on/off switch.

Image: Rear view of the cabinet, showing the power cord connection point and the main power switch.

4. Operating Instructions

The control panel features touch buttons for various functions.

Close-up of the DERMALOGIC control panel with touch buttons for UVC, UVC + HEAT, AUTO, and Power.

Image: Close-up of the control panel, displaying touch buttons for Power, UVC, UVC + HEAT, and AUTO functions.

  1. Loading Items: Open the door and carefully place instruments or towels on the racks. Do not overload the cabinet. Ensure items are clean and dry before placing them inside.
  2. Power On: Press the 'Power' button to turn on the unit.
  3. Select Mode:
    • UVC: Press the 'UVC' button for UV sterilization only. This mode is suitable for items that do not require heat.
    • UVC + HEAT: Press the 'UVC + Heat' button for combined UV sterilization and heating. This mode is ideal for towels or instruments that benefit from heat. The heating function reaches up to 140°F (60°C).
    • AUTO: Press the 'Auto' button to activate the automatic cycle. In this mode, the cabinet will automatically perform a sterilization process every 3 hours.
  4. Automatic Shut-off: For safety, the UV lamps and heating element will automatically turn off if the door is opened during operation. Close the door to resume the cycle.
  5. Cycle Completion: Once the selected cycle is complete, carefully open the door and remove the sterilized items. Use heat-resistant gloves if the heating function was used.
  6. Power Off: Press the 'Power' button to turn off the unit when not in use.

5. Maintenance

  • Cleaning: Regularly clean the interior and exterior of the unit with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the unit is unplugged and cool before cleaning.
  • UV Lamp Replacement: UV lamps have a limited lifespan. If the UV light appears dim or stops working, contact DERMALOGIC customer support for replacement instructions and genuine parts.
  • Rack Cleaning: The stainless steel racks can be removed for separate cleaning. Wash with mild soap and water, then dry thoroughly before returning them to the cabinet.

6. Troubleshooting

ProblemPossible CauseSolution
Unit does not power on.Power cord not connected; Power switch off; Outlet malfunction.Ensure power cord is securely plugged in; Check main power switch; Test outlet with another appliance.
UV light not working.Door open; UV lamp expired or damaged.Ensure door is fully closed; Contact customer support for lamp replacement.
Heating function not working.Door open; 'UVC + Heat' mode not selected.Ensure door is fully closed; Select 'UVC + Heat' mode.
Automatic cycle not activating.'Auto' mode not selected.Ensure 'Auto' mode is selected after powering on.

If problems persist after attempting these solutions, please contact DERMALOGIC customer support.

7. Specifications

FeatureSpecification
ModelKGO-SAAPP-60
Capacity60 Liters
FunctionsUV Sterilization, Ozone Sanitization, Heating
Input Power170W
UV Lamp Power2 x 10W
Heating TemperatureUp to 140°F (60°C)
MaterialStainless Steel
Unit Dimensions (W x L x H)17.5" x 14.5" x 25.5" (44.45 x 36.83 x 64.77 cm)
EPA No.102999-CHN-1
Product label showing model KGO-SAAPP-60, capacity 30L, voltage 110V, power rating 10W, and EPA No. 102999-CHN-1.

Image: Product label displaying model number, capacity, voltage, power rating, and EPA number. Note: The label shows 30L capacity, while the product description states 60L. Please refer to the product listing for the correct capacity.

8. Warranty and Support

For warranty information, technical support, or to purchase replacement parts, please contact DERMALOGIC customer service through their official website or the retailer where the product was purchased. Keep your purchase receipt as proof of purchase.

© 2023 DERMALOGIC. All rights reserved.

Ask a question about this manual