Temtop LKC-1000S 2nd

Temtop Air Quality Monitor User Manual

Model: LKC-1000S 2nd

Brand: Temtop

1. Introduction

The Temtop LKC-1000S 2nd generation Air Quality Monitor is a professional device designed to provide comprehensive insights into your indoor and outdoor air quality. It accurately measures key air factors including particulate matter (PM2.5 and PM10), formaldehyde (HCHO), humidity, temperature, and the Air Quality Index (AQI).

Equipped with pre-calibrated Dart electrochemical sensors and an industrial-grade laser particle sensor with a lifetime of up to 20,000 hours, this monitor ensures accurate and stable measurements. Its user-friendly design features a large TFT screen with a 6-level colorful health indicator for easy readability.

Temtop Air Quality Monitor highlighting key features like PM2.5, PM10, Particles, AQI, Temperature, Humidity, Formaldehyde, and Data Export.

Figure 1: Temtop LKC-1000S 2nd Generation Air Quality Monitor and its measured parameters.

2. Product Overview

The LKC-1000S 2nd features a robust design with intuitive controls and a clear display. Familiarize yourself with the device's components for optimal use.

Front view of the Temtop LKC-1000S 2nd Air Quality Monitor showing its display and control buttons.

Figure 2: Front view of the Temtop LKC-1000S 2nd Air Quality Monitor.

2.1. Device Components

Diagram of the Temtop Air Quality Monitor showing Air Outlet, Air Inlet, LCD Screen, AQI/Temp & Humi button, PM2.5/PM10/Particles button, HCHO button, and Power/Play/Pause button.

Figure 3: User-friendly monitor layout with labeled components.

  • LCD Screen: Displays real-time readings, battery status, and operational modes.
  • Power Button: Press and hold to turn on/off. Single click to switch between display modes (AQI, PM2.5/PM10/Particles, HCHO).
  • PM2.5/PM10/Particles Button: Cycles through particulate matter and particle count displays.
  • AQI/Temp & Humi Button: Displays Air Quality Index, temperature, and humidity.
  • HCHO Button: Displays Formaldehyde readings.
  • Air Inlet/Outlet: Located on the sides and top/bottom for air circulation to sensors.

2.2. Internal Sensors

Exploded view of the Temtop Air Quality Monitor showing the DART Electrochemical HCHO Sensor, SENSIRION Temp & Humi Sensor, and Temtop Laser PM2.5 Sensor (3rd Gen).

Figure 4: Internal sensor components for accurate measurements.

  • DART Electrochemical HCHO Sensor: Accurately captures formaldehyde molecules.
  • SENSIRION Temp & Humi Sensor: Provides precise temperature and humidity readings.
  • Temtop Laser PM2.5 Sensor (3rd Gen.): Industrial-grade sensor for accurate particle measurement with a 20,000-hour lifetime.

3. Initial Setup

3.1. Unboxing and Charging

Upon receiving your Temtop Air Quality Monitor, carefully unbox all components. The package includes the LKC-1000S 2nd generation dust monitor, a built-in large capacity lithium battery, a charging cable, and this user manual.

Contents of the Temtop Air Quality Monitor package: the monitor, storage box, user manual, and USB charging cable.

Figure 5: Package contents of the Temtop LKC-1000S 2nd.

Before first use, fully charge the device using the provided USB charging cable. Connect the cable to the charging port on the device and a compatible USB power source. The battery indicator on the screen will show charging progress.

3.2. Initial Calibration

For accurate readings, it is crucial to perform an initial calibration. Place the monitor outdoors in a fresh air environment for approximately one hour before its first use. This allows the sensors to stabilize and calibrate to baseline outdoor air quality levels, ensuring reliable measurements when used indoors.

4. Operation

4.1. Powering On/Off

  • To turn on the device, press and hold the power button (central button with a circle and vertical line) until the screen illuminates.
  • To turn off the device, press and hold the power button again until the screen turns off.

4.2. Interpreting Readings

The large TFT screen displays various air quality parameters. The device uses a 6-level colorful health indicator to help you easily understand the air quality at a glance, based on EPA standards.

Temtop Air Quality Monitor display showing color-coded air quality levels based on EPA standards: Good/Safe (Green), Moderate (Yellow), Unhealthy for Sensitive Groups (Orange), Unhealthy (Red), Very Unhealthy (Purple), Hazardous (Maroon).

Figure 6: Air quality health level indicator based on EPA standards.

  • PM2.5 / PM10 / Particles: These screens show the concentration of particulate matter and the number of particles per liter. Use the dedicated PM2.5 button to cycle through these displays.
  • Formaldehyde (HCHO): The HCHO button displays the concentration of formaldehyde.
  • AQI / Temperature / Humidity: The AQI button cycles through the Air Quality Index, current temperature, and humidity levels.

4.3. Important Usage Notes

  • Do not cover the vents of the detector.
  • Do not let fluff or excessive dust enter the detector, as this may damage the particle sensor.
  • Avoid using the detector for a long time in a humid environment or strong irritating odor environment to ensure measurement accuracy.
  • Avoid measuring visible particles like heavy smoke or pollen, as this can damage the sensor and lead to inaccurate readings. The device is intended for particles 10 micrometers or smaller.

5. Data Management

The Temtop LKC-1000S 2nd offers a convenient data export function, allowing you to track and analyze air quality trends over time. The device's memory is capable of storing at least 3 months of continuous data recording.

5.1. Data Export

To export data, connect the monitor to your computer using the provided USB cable. The device will appear as a removable storage device, and you can access the stored data files for analysis (e.g., in spreadsheet software).

Temtop Air Quality Monitor connected to a laptop, illustrating the data storage and export function to a spreadsheet.

Figure 7: Data storage and export functionality via USB.

6. Specifications

Feature Detail
Product Dimensions 1.93 x 5.98 x 8.82 inches
Item Model Number LKC-1000S 2nd
Batteries 1 Lithium Ion battery (included)
Item Weight 1.04 Pounds
Sensor Type Electrochemical (HCHO), Laser (PM2.5)
Power Source Battery Powered
Color Black/Orange
Manufacturer Elitech
Country of Origin China

7. Maintenance

  • Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Sensor Care: The internal laser sensor is sensitive. Avoid exposing the device to excessively dusty, misty (e.g., paint, hair spray), or smoky environments for prolonged periods, as this can foul the optics and affect accuracy.
  • Storage: When not in use, store the monitor in its original storage box in a cool, dry place away from direct sunlight and extreme temperatures.

8. Troubleshooting

If you encounter issues with your Temtop Air Quality Monitor, please refer to the following common solutions:

  • Inaccurate Readings: Ensure the device has been properly calibrated by leaving it in fresh outdoor air for at least an hour before use. Avoid using it in environments with visible particles or strong odors that could interfere with sensor operation.
  • Device Not Turning On: Check the battery level. Connect the device to the charging cable and allow it to charge for a few hours.
  • Display Issues: If the screen is unresponsive or shows abnormal characters, try restarting the device by holding the power button. If the issue persists, contact customer support.

For more detailed troubleshooting steps or issues not listed here, please consult the full user manual (PDF) or contact Temtop customer support.

9. Warranty & Support

Your Temtop LKC-1000S 2nd Air Quality Monitor comes with a 12-month warranty from the date of purchase, covering manufacturing defects and malfunctions under normal use.

Temtop is committed to providing excellent customer service. For any questions, technical assistance, or warranty claims, please utilize our 24/7 customer support accessible via Email and phone.

You can also download the official User Manual (PDF) for comprehensive instructions and information:

Download User Manual (PDF)

10. Official Product Videos

Watch the official video demonstrating the Temtop air quality monitor's application and smart connectivity features.

Video Description: This video demonstrates the application of the Temtop air quality monitor, including its smart connectivity features for real-time insights into air quality at home via a mobile app.

Related Documents - LKC-1000S 2nd

Preview Temtop LKC-1000 Series Air Quality Monitor User Manual
User manual for the Temtop LKC-1000 Series Air Quality Monitor, detailing its functions, specifications, operation, and maintenance.
Preview Temtop LKC-1000 Series Air Quality Monitor User Manual
User manual for the Temtop LKC-1000 Series Air Quality Monitor, providing detailed information on features, specifications, operation, calibration, and troubleshooting for accurate indoor air quality monitoring.
Preview Temtop P100/M100 Air Station User Manual: Comprehensive Air Quality Monitoring
User manual for the Temtop P100 and M100 Air Stations. Learn about monitoring PM2.5, PM10, CO2, temperature, and humidity with detailed explanations, specifications, and operational guides.
Preview Temtop M2000 Series Air Quality Monitor User Manual
User manual for the Temtop M2000 Series Air Quality Monitor, detailing its features, operation, specifications, and maintenance.
Preview Temtop S1+ Air Quality Monitor User Manual
Comprehensive user manual for the Temtop S1+ Air Quality Monitor, detailing features, specifications, operation, and troubleshooting for monitoring PM2.5 and AQI.
Preview Temtop S1 Air Quality Monitor User Manual - PM2.5 & AQI Detector
Comprehensive user manual for the Temtop S1 Air Quality Monitor. Learn about PM2.5, AQI, temperature, and humidity readings, device specifications, operation, troubleshooting, and warranty information.