Introduction
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your A-iPower SUA2301i Portable Inverter Generator. Please read this manual thoroughly before operating the generator to ensure proper use and to prevent injury or damage.
Important Safety Information
WARNING: Carbon Monoxide Hazard. Using a generator indoors WILL KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide, a poison gas you cannot see or smell. NEVER use in a home or in partly enclosed areas such as garages. Only use OUTSIDE and far from open windows, doors, and vents.
- Always operate the generator in a well-ventilated outdoor area.
- Ensure proper grounding to prevent electric shock.
- Do not expose the generator to rain or wet conditions.
- Check for fuel overflow or leakage before starting.
- Equipped with a CO sensor with auto shutdown technology for enhanced safety.
Setup and First Use
Unpacking and Included Components
Carefully remove all components from the packaging. Verify that all items are present:
- Generator Unit (SUA2301i)
- Manual/Quick Start Guide
- Funnel
- Engine Oil (10W-30)
- 12VDC Charging Cables
- 30A RV Adaptor
- Tool Kit
- Parallel Cables (included for parallel operation)

Figure 1: Included components with the SUA2301i generator, including oil, funnel, cables, and tools.
Adding Engine Oil
Before first use, add the provided 10W-30 engine oil to the generator's crankcase. Refer to the oil fill cap for the correct level. Do not overfill.
Adding Fuel
This generator operates on gasoline. Fill the 0.9-gallon fuel tank with fresh, unleaded gasoline. Ensure the fuel cap is securely tightened after filling.

Figure 2: Top view of the SUA2301i generator showing the fuel cap.
Operating Instructions
Control Panel Overview
The multi-featured control panel provides all necessary controls and indicators for operation.

Figure 3: Detailed view of the SUA2301i control panel, highlighting various outlets and indicators.
- CO Sensor Indicator Light: Alerts to dangerous levels of carbon monoxide.
- LED Light: Illuminates the control panel for visibility in low light.
- Data Center Display: Shows Voltage, Hours, Frequency, Power, and Fuel level.
- Outlets:
- 1x L5-30R 30A 120V
- 1x Duplex 5-20R 20A 120V
- 1x 8.3A 12VDC
- 1x USB-A 3.6A
- 1x USB-C 3.0A
- Output Indicator: Shows when power is being generated.
- Overload Alarm: Indicates when the generator is overloaded.
- Low Oil Alert: Warns of low engine oil levels.
- Low Idle Mode (Eco Mode): Reduces engine speed to conserve fuel and lower noise when power demand is low.
Starting the Generator
- Ensure the generator is on a level surface outdoors, away from windows and doors.
- Turn the fuel valve to the "ON" position.
- Turn the main switch to the "ON" position.
- For electric start, press and hold the "ENGINE START/STOP" button until the engine starts.
- For manual recoil start, pull the recoil cord firmly until the engine starts.
- Allow the generator to warm up for a few minutes before connecting electrical loads.
Video 1: Official A-iPower video demonstrating the features and operation of the SUA2301i 2300 Watt Inverter Generator.
Connecting Electrical Loads
- Connect your devices to the appropriate outlets on the control panel.
- Do not exceed the running wattage of 1800W or the starting wattage of 2300W.
- For sensitive electronics, the inverter technology provides clean power with less than 3% Total Harmonic Distortion (THD).
Parallel Operation
The SUA2301i is parallel equipped, allowing you to connect two identical generators for increased power output. Use the provided parallel cables and follow the instructions in the separate parallel kit manual for safe connection.
Maintenance
Regular maintenance ensures the longevity and optimal performance of your generator.
- Engine Oil: Check oil level before each use. Change oil regularly as per the maintenance schedule in the full owner's manual.
- Air Filter: Inspect and clean the air filter regularly. Replace if damaged.
- Spark Plug: Inspect and clean the spark plug periodically. Replace if worn or fouled.
- Fuel System: For long-term storage, it is recommended to drain the carburetor and fuel tank to prevent fuel degradation. Use a fuel stabilizer if storing with fuel in the tank.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Generator will not start | No fuel, low oil, main switch off, fuel valve off. | Add fuel, add oil, turn main switch ON, turn fuel valve ON. |
| No power output | Overload, circuit breaker tripped. | Reduce load, reset circuit breaker. |
| Engine stops during operation | Low fuel, low oil, CO sensor activated. | Add fuel, add oil, move generator to well-ventilated area. |
For more detailed troubleshooting, please consult the full owner's manual or contact customer support.
Specifications
| Feature | Detail |
|---|---|
| Model Name | 2300 Watt Inverter Generator (SUA2301i) |
| Brand | A-iPower |
| Starting Wattage | 2300 Watts |
| Running Wattage | 1800 Watts |
| Fuel Type | Gasoline |
| Tank Volume | 0.9 Gallons |
| Runtime (at 25% load) | 9 hours |
| Voltage | 120 Volts |
| Current Rating | 19.17 Amps |
| Frequency | 60 Hz |
| Engine Type | 80cc OHV 4-Cycle Engine |
| Sound Level | 52 dB |
| Item Weight | 42.2 Pounds |
| Product Dimensions (L x W x H) | 21.5"L x 12.8"W x 21.1"H |
Warranty and Support
A-iPower stands behind its products with a 3-Year Limited Manufacturer's Warranty. For technical assistance, parts, or warranty claims, please contact A-iPower customer support.
Visit the official A-iPower Store for more information and product registration: A-iPower Store