DINUY PT Sup EL4

DINUY PT Sup EL4 3-Wire Tactile Push-Button Timer Instruction Manual

Model: PT Sup EL4

1. Introduction

This manual provides detailed instructions for the safe installation, correct operation, and proper maintenance of the DINUY PT Sup EL4 3-Wire Tactile Push-Button Timer. Please read this manual thoroughly before attempting any installation or operation to ensure optimal performance and safety. Keep this manual for future reference.

2. Safety Information

WARNING: Electrical installation should only be performed by a qualified and licensed electrician.

3. Product Overview and Features

The DINUY PT Sup EL4 is a sophisticated 3-wire tactile push-button timer designed for controlling various types of lighting fixtures. Its modern design and advanced features make it suitable for a wide range of residential and commercial applications.

DINUY PT Sup EL4 Tactile Push-Button Timer

Figure 1: Front view of the DINUY PT Sup EL4 Tactile Push-Button Timer. This image shows the white square-shaped device with a central power symbol, a small blue LED indicator, and two visible mounting screws.

Key Features:

4. Installation Instructions

Before beginning installation, ensure the main power supply to the circuit is turned OFF at the circuit breaker. This device is designed for surface mounting in a universal box.

4.1 Wiring Diagram

The DINUY PT Sup EL4 requires a 3-wire connection. Refer to the diagram below for correct wiring.

Wiring Diagram for DINUY PT Sup EL4

Figure 2: Wiring diagram for the DINUY PT Sup EL4. The diagram illustrates a 3-wire connection: 'L' for Phase, 'N' for Neutral, and a connection to the lamp. The dashed lines indicate optional connections for additional push-buttons (L) or neutral (N) connections.

4.2 Mounting

  1. After wiring, carefully place the device into the universal wall box.
  2. Secure the device to the wall box using the provided security screws. Do not overtighten.
  3. Once mounted, restore power at the main circuit breaker.

5. Operating Instructions

5.1 Basic Operation

5.2 Timer Function

6. Maintenance

The DINUY PT Sup EL4 is designed for long-term, maintenance-free operation. However, periodic cleaning and inspection can help ensure its longevity and proper function.

7. Troubleshooting

If you experience issues with your DINUY PT Sup EL4, refer to the following common troubleshooting steps:

ProblemPossible CauseSolution
Light does not turn on.No power to the device.
Incorrect wiring.
Faulty lamp.
Check the circuit breaker. Ensure power is restored.
Verify wiring against the diagram (Section 4.1).
Test the lamp with another switch or replace it.
Light stays on permanently or turns off too quickly.Timer setting issue.
Device malfunction.
The timer duration is factory set or adjusted internally. If the behavior is inconsistent with expected operation, consult a qualified electrician.
If the issue persists after checking power and wiring, the device may require professional inspection.
Blue LED indicator is off.No power to the device.Check the circuit breaker and ensure power is supplied to the device.

If these steps do not resolve the issue, contact a qualified electrician or the manufacturer's support for assistance. Do not attempt to repair the device yourself.

8. Detailed Specifications

ParameterValue
Supply Voltage230 V AC
Frequency50 Hz
Self-consumption0.7 W
Relay Cut-off Power16 A
Max. Load (LED Lamps)400 W
Max. Load (Incandescent & Halogen 230V)3000 W
Max. Load (Halogen 12V with Electronic Transformer)3000 W
Max. Load (Halogen 12V with Ferromagnetic Transformer)2400 W
Max. Load (Fluorescent Lamps)1300 W (1300 VA)
Contactor SupportYes
Zero-Crossing DetectionYes
Installation Type3 wires (Phase, Neutral, Lamp Return)
Permanent Lighting FunctionNo
Stop Warning FunctionNo
Minimum Timer Duration30 seconds
Maximum Timer Duration12 minutes
Timed SwitchNo
Luminous Push-buttons SupportNo
Operating Temperature0°C to 40°C
Permanent Luminous LEDYes
MountingUniversal box, Surface, Security screws
Environmental ProtectionIP20 (according to UNE20324)
Compliance StandardsUNE-EN60669-2-1 and UNE-EN60669-2-3

9. Warranty and Support

Specific warranty information for the DINUY PT Sup EL4 is typically provided at the point of purchase or within the product packaging. Please refer to your purchase documentation for details regarding warranty coverage and duration.

For technical support, troubleshooting assistance beyond what is provided in this manual, or warranty claims, please contact your retailer or the official DINUY customer service. Contact information can usually be found on the manufacturer's website or product packaging.

Related Documents - PT Sup EL4

Preview DINUY Temporized Tactile Pushbutton - Installation and User Manual
Comprehensive manual for DINUY's Temporized Tactile Pushbutton, covering installation, technical specifications, and operation for models like PT EMP EL4, PT SUP EL4, and PT GAR EL1.
Preview DINUY IHEMT 1328 Timer Switch User Manual
User manual for the DINUY IHEMT 1328 timer switch, providing operating instructions, installation guidelines, and connection diagrams in multiple languages.
Preview DINUY Electrical Device Installation Guide
Step-by-step installation instructions for DINUY electrical devices, covering mounting and wiring. Includes model numbers and connection details.
Preview DINUY Laüka Dot KNX Capacitive Switch with Temperature and Luminosity Sensors + Thermostat Function Manual
Instructions and technical specifications for the DINUY Laüka Dot KNX capacitive switch, featuring 2, 4, 6, or 8 buttons, integrated temperature and luminosity sensors, and a thermostat function. Includes installation and commissioning guidance.
Preview Manual de Interruptores Horarios Modulares Digitales DINUY IH TER MC/TEB MC
Manual de usuario completo para los interruptores horarios modulares digitales DINUY IH TER MC0, IH TEB MC0, IH TER MC2 e IH TEB MC2, cubriendo instalación, programación y características vía NFC.
Preview Declaración de Conformidad CE - Regulador Univ. Planta 400 W. DINUY
Documento de Declaración de Conformidad CE para el Regulador Univ. Planta 400 W. (RE PLA 000) fabricado por DINUY, S.A., cumpliendo directivas europeas y normas aplicables.