Introduction
The Elitech RC-51 Digital Temperature Data Logger is a reusable USB device designed for precise temperature monitoring. It records up to 32,000 temperature points and automatically generates PDF reports, making it ideal for various applications including cold chain management, vaccine storage, and industrial processes.
Key Features
- Reusable Temperature Data Logger: Wide temperature measuring range -22℉~158℉(-30°C ~+70°C), records up to 32,000 temperature points.
- Plug and Play: USB port, generates PDF report automatically after connecting to PC, no software needed for report generation.
- LCD Visual Display: Press the button to switch interface of key information: current temperature value, Max or Min value, Current Date, Logging points. Fahrenheit /Celsius switchable.
- Multiple Start Option & Alarm Settings: Start options include pressing the button on the data logger, pre-set time start, or start delay via Elitechlog software. Supports up to 5 alarm settings.
- IP67 Waterproof Design: Ensures durability and reliability in various environments.
Product Overview


Setup
The RC-51 data logger is designed for ease of use. Before initial use, it is recommended to configure the device parameters using the Elitechlog software, which can be downloaded from the Elitech website. Parameters such as logging interval, start options, and alarm settings can be customized.
- Software Installation: Download and install the Elitechlog software on your computer (Windows or macOS compatible).
- Connect Device: Remove the transparent cap to reveal the USB port. Plug the data logger into an available USB port on your computer.
- Configure Settings: Open the Elitechlog software. The device should be recognized automatically. Use the software interface to set desired logging parameters, including start mode (button press, timed, or delay), logging interval, and temperature alarm thresholds.
- Disconnect Safely: After configuration, safely eject the device from your computer.

Operating Instructions
Starting a Recording Session
- Button Start: If configured for button start, press and hold the button on the data logger until the "REC" icon appears on the LCD, indicating recording has begun.
- Timed Start: If configured for timed start, the device will automatically begin recording at the pre-set time.
- Delay Start: If configured for delay start, the device will begin recording after a specified delay period once activated.
Monitoring Data on LCD
A single click on the button allows browsing through various LCD display pages:
- Current temperature value
- Maximum (Max) temperature value
- Minimum (Min) temperature value
- Current Date
- Logging points (number of recorded data points)
- Fahrenheit / Celsius switchable display

Stopping a Recording Session
Recording will stop automatically when the memory is full, or when the device is connected to a computer and a report is generated. If configured, recording can also be stopped by pressing and holding the button on the device.
Generating Reports
To generate a report, simply plug the data logger into a USB port on your computer. The device will automatically create an encrypted PDF report. The Elitechlog software can also be used to export data in PDF, Excel, or TXT formats for more detailed analysis and comparison.


Maintenance
- Cleaning: Wipe the device with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Battery: The device uses a Lithium Metal battery (included). Refer to the Elitechlog software or device specifications for battery life and replacement information.
- Storage: Store the data logger in a cool, dry place when not in use. Ensure the transparent cap is securely in place to protect the USB port.
- Calibration: For critical applications, regular calibration is recommended. Elitech provides a two-year validation certificate.


Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device not starting recording. | Incorrect start mode configuration; battery low; device not activated. | Check settings in Elitechlog software. Ensure battery is charged. Press and hold the button to activate if configured for button start. |
| No PDF report generated. | USB connection issue; device memory full; corrupted data. | Ensure secure USB connection. Try a different USB port. Check device memory status. Reformat device if data is not critical (this will erase all data). |
| Inaccurate temperature readings. | Sensor obstruction; device placed in extreme conditions; calibration needed. | Ensure sensor is clear. Operate within specified temperature range. Consider professional calibration if accuracy is critical. |
| LCD display not working. | Low battery; device malfunction. | Charge or replace battery. If problem persists, contact customer support. |
Specifications
| Attribute | Value |
|---|---|
| Model Number | RC-51 |
| Temperature Measuring Range | -22℉~158℉ (-30°C ~+70°C) |
| Temperature Accuracy | ±0.5°C |
| Resolution | 0.1°C |
| Data Storage Capacity | 32,000 points |
| Interface | USB |
| Battery | 1 Lithium Metal battery (included) |
| Product Dimensions | 0.94 x 0.94 x 5.16 inches |
| Weight | 2.82 ounces |
| Protection Class | IP67 |
| Manufacturer | Elitech |

Warranty and Support
The Elitech RC-51 Digital Temperature Data Logger comes with a two-year validation certificate, ensuring its quality and performance. For any technical assistance, Elitech offers 24/7 US Technician Support via Email and Phone. Please refer to the official Elitech website or the included documentation for specific warranty terms and contact information.
For calibration certificates or further inquiries, please email or message Elitech customer service.