VEVOR 1 HP Refrigerant Recovery Machine

VEVOR 1 HP Refrigerant Recovery Machine User Manual

Model: 1 HP Refrigerant Recovery Machine

Brand: VEVOR

Introduction

This user manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your VEVOR 1 HP Refrigerant Recovery Machine. Please read this manual thoroughly before operating the machine to ensure proper usage and to prevent damage or injury.

VEVOR 1 HP Refrigerant Recovery Machine

Figure 1: VEVOR 1 HP Refrigerant Recovery Machine, showcasing its compact design and control panel.

Safety Instructions

Always adhere to the following safety precautions to prevent personal injury or damage to the equipment:

Product Overview and Components

The VEVOR 1 HP Refrigerant Recovery Machine is designed for efficient recovery of various refrigerants. Key components include:

Front view of the VEVOR Refrigerant Recovery Machine

Figure 2: Detailed front view of the machine, highlighting gauges and control knob.

Diagram showing 59% increased recycling speed

Figure 3: Illustration of the machine's high-efficiency dual-cylinder configuration, enabling faster recovery rates.

What's in the Box

Setup

Before initial use, ensure all components are present and undamaged. Connect the power cord to a compatible 120V 60Hz power outlet. Place the machine on a stable, level surface in a well-ventilated area.

Refrigerant recovery machine connected to an AC unit

Figure 4: The recovery machine set up for use with an outdoor AC unit, demonstrating hose connections.

Refrigerant recovery machine connected to a refrigerator

Figure 5: The recovery machine connected to a refrigerator, illustrating its versatility for various refrigeration equipment.

Operating Instructions

Follow these steps for refrigerant recovery and purging:

1. Refrigerant Recovery

  1. Connect the 'IN' port of the recovery machine to the system being recovered using appropriate hoses.
  2. Connect the 'OUT' port of the recovery machine to a certified recovery tank.
  3. Ensure all connections are tight and leak-free.
  4. Turn the control knob to either RECOVER SLOW or RECOVER FAST depending on the desired speed.
  5. Press the START button. The machine will begin recovering refrigerant.
  6. Monitor the pressure gauges during operation. The machine will automatically shut off if pressure exceeds 38.6 bar / 558 psi.
  7. Once recovery is complete, turn the control knob to OFF.
Control knob showing different recovery modes

Figure 6: Close-up of the control knob, illustrating the RECOVER SLOW, RECOVER FAST, and PURGE settings.

Diagram showing compatibility with various refrigerants

Figure 7: Visual representation of the machine's broad compatibility with different refrigerant types for cars, air conditioners, and refrigerators.

2. Self-Cleaning (Purge Function)

After each use, utilize the self-cleaning function to discharge any leftover refrigerant and prevent machine damage:

  1. Ensure the 'OUT' port is connected to the recovery tank.
  2. Turn the control knob to PURGE.
  3. The machine will activate its self-cleaning function, safely discharging residual refrigerant.
  4. Once the purge cycle is complete, turn the control knob to OFF.

Official Product Video

Video 1: An overview of the VEVOR 1HP Refrigerant Recovery Machine, demonstrating its features and proper usage. The video highlights the dual-cylinder design, high-pressure protection, and self-cleaning function, providing a visual guide to the machine's operation and benefits for HVAC and automotive applications.

Maintenance

Regular maintenance ensures optimal performance and longevity of your recovery machine:

Diagram showing filter net and advanced dryer for impurity isolation

Figure 8: Illustration of the dual barrier system, including the filter net and advanced dryer, designed to isolate impurities and water from the refrigerant.

Troubleshooting

Refer to the table below for common issues and their potential solutions:

ProblemPossible CauseSolution
Machine does not start.No power; Circuit breaker tripped.Check power connection; Reset circuit breaker (wait 5 minutes if tripped).
Slow recovery rate.Clogged filter; Low system pressure; Incorrect mode.Clean/replace filter; Ensure adequate system pressure; Select RECOVER FAST mode.
Machine shuts off during operation.High pressure protection activated.Check for blockages in hoses/system; Ensure recovery tank is not full.
Refrigerant not recovering.Incorrect hose connection; Valves closed.Verify hose connections; Open all necessary valves.

Specifications

FeatureDetail
Net Weight30.9 lbs / 14 kg
Power1 HP
Voltage120V ~ 60Hz
High Pressure Protection558 PSI / 38.6 Bar
Operating Temperature32°F-104°F / 0-40°C
Max. Liquid Recovery Rate7.7 lb / min
Rotation Speed1750 RPM
Air Inlet Interface1/4" SAE
Exhaust Interface1/4" SAE
Product Dimensions9.8 x 15.7 x 14.2 inches
Dimensions and specifications of the VEVOR Refrigerant Recovery Machine

Figure 9: Visual representation of the machine's dimensions and key specifications.

Warranty and Support

VEVOR products come with a warranty. For detailed warranty information, technical support, or service inquiries, please visit the official VEVOR website or contact their customer service. Keep your purchase receipt for warranty claims.

For more information, visit: vevor.com/support

Related Documents - 1 HP Refrigerant Recovery Machine

Preview VEVOR RR250 Refrigerant Recovery Machine Operating Manual
This operating manual provides detailed instructions for the VEVOR RR250 Refrigerant Recovery Machine, covering technical specifications, safety guidelines, operational procedures, and troubleshooting steps for efficient and safe refrigerant recovery.
Preview VEVOR Vacuum Pump Manifold Gauge Set Operating Manual - KQ-1K
Comprehensive operating manual for the VEVOR Vacuum Pump Manifold Gauge Set (Model KQ-1K). Includes introduction, safety precautions, getting started guide, specifications, package contents, operation guide, maintenance, and troubleshooting.
Preview VEVOR RR250 Refrigerant Recovery Machine Operating Manual
Comprehensive operating manual for the VEVOR RR250 Refrigerant Recovery Machine, covering safety, specifications, operation, and troubleshooting for efficient refrigerant handling.
Preview VEVOR Vacuum Pump Manifold Gauge Set: Operating Manual & Guide
Comprehensive operating manual and user guide for the VEVOR Vacuum Pump Manifold Gauge Set (KQ-1K, KQ-1.5K). Learn about features, safety, operation, and maintenance for AC systems.
Preview VEVOR Vacuum Pump Refrigerant Meter Group User Manual | Safety, Operation, Maintenance
This user manual for the VEVOR Vacuum Pump Refrigerant Meter Group provides comprehensive instructions on safety, operation, maintenance, and troubleshooting. It includes technical specifications for various VEVOR vacuum pump models, essential for HVAC and refrigeration tasks. Learn how to effectively use and care for your VEVOR vacuum pump.
Preview VEVOR Vacuum Pump Manifold Gauge Set Operating Manual - KQ-1K, KQ-1.5K
Comprehensive operating manual for the VEVOR Vacuum Pump Manifold Gauge Set (models KQ-1K, KQ-1.5K). Learn about safety, operation, maintenance, and troubleshooting for AC systems. Includes tools for vacuuming and refrigerant recharging.