XIIW LFWW-09QT

Download PDFFree PDF. The Save button below keeps a bookmark and private notes in your account.

XIIW Bathroom Extractor Fan Ø100mm with Timer and Backdraft Damper

Model: LFWW-09QT

1. Introduction

Thank you for choosing the XIIW Bathroom Extractor Fan. This manual provides essential information for the safe installation, operation, and maintenance of your new extractor fan. Please read these instructions carefully before installation and use, and retain them for future reference.

This Ø100mm extractor fan is designed to effectively remove moisture and odors from bathrooms, toilets, kitchens, and cellars, improving indoor air quality. It features a quiet operation, an adjustable timer, and an integrated backdraft damper for enhanced performance.

2. Safety Information

  • Always disconnect the power supply before installation, maintenance, or cleaning.
  • Installation must be performed by a qualified electrician and in accordance with all local and national wiring regulations.
  • Ensure the power supply voltage matches the fan's specifications (220V AC).
  • Do not install the fan in areas where flammable or explosive gases are present.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Keep children away from the fan during operation and maintenance.
  • Do not block the air inlet or outlet during operation.
  • The fan is rated IPX4, meaning it is protected against splashing water from any direction. However, avoid direct water jets.

3. Package Contents

Please check that all components are present and undamaged:

  • XIIW Bathroom Extractor Fan (Model LFWW-09QT)
  • Wall Mount Bracket
  • Instruction Manual
  • Mounting Screws and Wall Plugs

4. Product Features

  • Adjustable Timer (0-30 minutes): The fan continues to operate for a set duration after being switched off, effectively removing residual moisture and odors.
  • Ultra-Quiet Operation: Operates at less than 34dB, ensuring minimal noise disturbance.
  • Integrated Backdraft Damper: Prevents external air and odors from re-entering the room.
  • High Airflow: Provides an airflow of 95m³/h for efficient ventilation.
  • Energy Efficient: Low power consumption of 12W.
  • Durable Construction: Made from UV-resistant, non-yellowing ABS plastic.
  • IPX4 Waterproof Rating: Protected against splashing water.
XIIW Bathroom Extractor Fan with Timer and Backdraft Damper

Image 1: Overview of the XIIW Bathroom Extractor Fan highlighting its features like 95m³/h airflow, 34dB quiet operation, and IPX4 water resistance.

Close-up of the backdraft damper mechanism

Image 2: Detailed view of the double protection backdraft damper, illustrating how it blocks cold air and insects.

5. Installation

The XIIW extractor fan is suitable for wall, ceiling, or window mounting. Ensure the mounting surface is flat and stable. Refer to the wiring diagram for electrical connections.

5.1 Wiring Diagram

Proper wiring is crucial for safe and correct operation, especially for the timer function. Consult a qualified electrician for installation.

Wiring diagram for XIIW extractor fan with and without light connection

Image 3: Wiring diagrams for the extractor fan. Left: Fan connected to a switch. Right: Fan connected to a switch and a light. LT = Live (Phase), N = Neutral. Isolation Class II, no earth wire required. Complies with DIN EN 61140.

5.2 Mounting Instructions

  1. Choose a suitable location for mounting (wall, ceiling, or window).
  2. Mark the drilling points for the mounting bracket.
  3. Drill holes and insert wall plugs. Secure the mounting bracket.
  4. Connect the electrical wires according to the wiring diagram.
  5. Attach the fan unit to the mounting bracket.
  6. For vertical mounting (e.g., ceiling), it is imperative to remove the backdraft damper to ensure proper function.
Diagrams for wall and ceiling installation

Image 4: Installation diagrams showing wall mounting with PVC tube and ceiling mounting with flexible ducting. Note for ceiling mounting: remove the backdraft damper.

6. Operation

The fan operates when power is supplied. The integrated timer allows for delayed shutdown.

6.1 Timer Adjustment

The timer can be adjusted from 1 to 30 minutes. To adjust the timer, you need to access the internal circuit board by carefully opening the fan cover. Use a small screwdriver to gently pry open the cover as shown in Image 5.

Opening the fan cover with a screwdriver

Image 5: Illustration of how to open the fan cover using a screwdriver to access internal components.

Once the cover is open, locate the adjustment button on the circuit board. The LED indicator will confirm your selection.

  • Factory Setting: 1 minute
  • Press once: 5 minutes
  • Press twice: 10 minutes
  • Press three times: 20 minutes
  • Press four times: 30 minutes
Timer adjustment button and settings

Image 6: Diagram showing the timer adjustment button on the circuit board and the corresponding delay settings for each press.

After setting the desired timer duration, carefully close the fan cover.

7. Maintenance

Regular cleaning ensures optimal performance and longevity of your extractor fan.

  • Disconnect Power: Always ensure the power supply is disconnected before any maintenance.
  • Clean Exterior: Wipe the exterior surface with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Clean Fan Blades: Carefully open the fan cover (refer to Section 6.1). Gently clean the fan blades and interior with a soft brush or cloth to remove dust and debris.
  • Reassemble: Ensure all parts are dry before reassembling the fan cover.

8. Troubleshooting

ProblemPossible CauseSolution
Fan does not turn on.No power supply.
Incorrect wiring.
Fan motor fault.
Check power connection and circuit breaker.
Verify wiring according to the diagram (Section 5.1).
Contact customer support if motor is faulty.
Fan is excessively noisy.Obstruction in fan blades.
Loose mounting.
Motor issue.
Disconnect power and check for debris in blades.
Ensure fan is securely mounted.
Contact customer support.
Timer function not working correctly.Incorrect timer setting.
Wiring issue.
Re-adjust timer settings (Section 6.1).
Check wiring, especially the LT connection for the timer.
Airflow is weak.Blocked air ducts.
Dirty fan blades.
Check and clear any obstructions in the ducting.
Clean fan blades (Section 7).

9. Specifications

SpecificationValue
BrandXIIW
Model NumberLFWW-09QT
Product Dimensions (L x W x H)15 x 15 x 15 cm
Weight660 grams
Duct Diameter100mm
Power12 Watts
Voltage220V AC
Airflow95 m³/h
Noise Level34 Decibels
Speed2400 RPM
Number of Blades7
MaterialPlastic (ABS)
Waterproof RatingIPX4
Special FeaturesTimer, Backdraft Damper
Mounting TypeWall Mount (also suitable for ceiling/window)
Country of OriginChina
Dimensional drawing of the XIIW extractor fan

Image 7: Detailed dimensions of the extractor fan, including the duct diameter and overall housing measurements.

10. Warranty and Support

This product comes with a standard manufacturer's warranty. Please refer to your purchase documentation for specific warranty terms and conditions. For technical support, troubleshooting assistance, or warranty claims, please contact your retailer or the XIIW customer service department.

© 2026 XIIW. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.