This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Franke FJO 624 XS 60cm Chimney Hood. Please read these instructions carefully before use and retain them for future reference.

Image 1: Front view of the Franke FJO 624 XS 60cm Chimney Hood. This stainless steel appliance is designed for wall mounting above a cooking surface.
Safety Information
Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury.
- Ensure the electrical installation complies with local regulations.
- Do not allow children to operate the appliance.
- Regularly clean grease filters to prevent fire hazards.
- Do not flambé under the range hood.
- Ensure adequate ventilation in the room when the range hood is used simultaneously with gas or other fuel-burning appliances.
- Disconnect the appliance from the main power supply before any cleaning or maintenance.
- Do not use the hood if the power cord is damaged. Contact qualified personnel for repair.
Setup and Installation
The Franke FJO 624 XS is a wall-mounted canopy hood. Proper installation is crucial for optimal performance and safety.
Dimensions and Clearance
Refer to the following dimensions for installation planning:
- Overall Product Dimensions (Depth x Width x Height): 47cm x 60cm x 100cm
- Base Width: 598-898 mm
- Base Depth: 471 mm
- Main Body Height: 200 mm
- Filter Minimum Height: 515 mm
- Filter Maximum Height: 795 mm
- Aspiration Minimum Height: 420 mm
- Aspiration Maximum Height: 795 mm
- Chimney Section Width (top): 126 mm
- Chimney Section Depth (top): 81 mm
- Chimney Section Height (top part): 169 mm
- Chimney Section Depth (lower part): 167 mm
- Ducting Outlet Height: 402 mm (from top of main body)
- Hood Edge Thickness: 25.5 mm
- Mounting Type: Wall Mount.
- Recommended Height: Ensure the hood is installed at the recommended distance above the cooking surface as per local safety regulations and the appliance manual (typically 65-75 cm for electric hobs and 75-85 cm for gas hobs).
- Ducting: This model supports ducted/vented operation. Connect the exhaust outlet to an external ventilation system using appropriate ducting.
Installation Steps (General)
- Mark the drilling points on the wall according to the provided template or dimensions.
- Drill holes and insert wall plugs.
- Secure the mounting bracket to the wall.
- Mount the hood body onto the bracket.
- Connect the ducting to the exhaust outlet.
- Install the chimney sections, ensuring they are securely fastened.
- Connect the appliance to the main power supply.
Operating Instructions
The Franke FJO 624 XS chimney hood features push-button controls for easy operation.
Control Panel
The control panel is located on the front of the hood and consists of push buttons for various functions.
- Power On/Off: Press the main power button to turn the hood on or off.
- Speed Selection: The hood has 3 speed settings. Press the corresponding button (1, 2, or 3) to select the desired extraction power.
- Speed 1: Low extraction for light cooking.
- Speed 2: Medium extraction for general cooking.
- Speed 3: High extraction for intense cooking or strong odors.
- Light Control: Press the light button to turn the LED lights on or off. The hood is equipped with 2x4W LED lights.
For best results, turn on the hood a few minutes before cooking and leave it running for a few minutes after cooking to clear residual fumes.
Maintenance
Regular maintenance ensures the longevity and optimal performance of your chimney hood.
Cleaning the Grease Filters
The hood is equipped with mesh filters designed to trap grease particles. These filters should be cleaned regularly, typically every 2-4 weeks depending on usage.
- Disconnect Power: Always switch off and unplug the hood from the power supply before cleaning.
- Remove Filters: Locate the filter release catches and carefully remove the mesh filters.
- Clean Filters: Wash the filters by hand in hot soapy water or in a dishwasher on a low-temperature cycle. Avoid using abrasive detergents.
- Dry and Reinstall: Ensure the filters are completely dry before reinstalling them.
Cleaning the Exterior
Clean the stainless steel exterior with a soft cloth and a non-abrasive cleaner specifically designed for stainless steel. Avoid harsh chemicals or abrasive pads that can scratch the surface.
Replacing Lights
If a light bulb needs replacement, ensure the hood is disconnected from power. Replace with a bulb of the same type and wattage (2x4W LED).
Troubleshooting
Before contacting customer service, refer to the following common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Hood does not turn on. | No power supply; power cord disconnected; fuse blown. | Check power connection; ensure plug is fully inserted; check household fuse/circuit breaker. |
| Poor extraction performance. | Grease filters are dirty; ducting is blocked or too long; wrong speed setting. | Clean or replace grease filters; check ducting for obstructions; select a higher speed setting. |
| Excessive noise during operation. | Loose components; improper installation; ducting issues. | Check for loose screws or parts; ensure proper installation; inspect ducting for kinks or restrictions. |
| Lights not working. | Bulb faulty; electrical connection issue. | Replace faulty bulb; check light switch and wiring. |
Specifications
Detailed technical specifications for the Franke FJO 624 XS Chimney Hood:
| Brand Name | Franke |
| Model Number | FJO 624 XS |
| Part Number | 320.0545.169 |
| Product Dimensions (Depth x Width x Height) | 47cm x 60cm x 100cm |
| Color | Silver |
| Finish Type | Coated |
| Airflow Capacity | 430 m³/h |
| Material | Stainless Steel |
| Mounting Type | Wall Mount |
| Control Type | Push Button |
| Number of Speeds | 3 |
| Item Weight | 249 grams (Note: This weight seems unusually low for a chimney hood. Please verify with product packaging.) |
| Light Source | LED (2x4W) |
| Electrical Power | 145 Watts |
| Filter Type | Mesh |
| Ventilation Type | Ducted/Vented |
| Product Shape | Rectangular |
| Noise Level (Min-Max) | 58 dB - 67 dB |
| Pressure | 300 Pa |
Warranty and Support
For warranty information, please refer to the documentation provided with your purchase or contact Franke customer support. Keep your proof of purchase for any warranty claims.
For technical assistance, spare parts, or service, please contact your local Franke service center or authorized dealer. You may need to provide the model number (FJO 624 XS) and part number (320.0545.169) when seeking support.
You can find more information on the official Franke website: www.franke.com
Related Documents - FJO 624 XS
![]() |
Franke Maris FME 407 Installation Manual Step-by-step installation guide for the Franke Maris FME 407 kitchen hood, including safety precautions, parts list, and mounting instructions. |
![]() |
Franke 780 T45 HE Cooker Hood - Installation, Use, and Maintenance Guide This guide provides comprehensive instructions for the Franke 780 T45 HE cooker hood, covering safety, installation, operation, care, maintenance, and warranty information. |
![]() |
Franke 780 T45 HE Cooker Hood: Installation and User Manual Comprehensive guide for installing, using, and maintaining the Franke 780 T45 HE cooker hood. Includes safety instructions, technical specifications, operation details, and servicing information. |
![]() |
Franke FMY 907 MG Range Hood Installation Manual Comprehensive installation guide for the Franke FMY 907 MG range hood, detailing safety precautions, parts, dimensions, and step-by-step assembly instructions. |
![]() |
Franke FSMS WALL F42 User Manual: Installation, Operation, and Maintenance Guide Comprehensive user manual for the Franke FSMS WALL F42 kitchen hood, covering installation, operation, safety, cleaning, and maintenance. Essential guide for proper use and care. |
![]() |
Franke FCMY 120 C WHG A AH User Manual User manual for the Franke FCMY 120 C WHG A AH cooker hood, providing installation, operation, cleaning, and safety instructions. |
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.