Leviton LP622-BPD 66 Space, 66 Circuit Indoor Load Center User Manual

Model: LP622-BPD

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the Leviton LP622-BPD 66 Space, 66 Circuit Indoor Load Center with a 225 Amp Main Circuit Breaker. Please read this manual thoroughly before proceeding with any installation or operation to ensure safe and correct usage of the product.

2. Safety Information

WARNING: Risk of electric shock or electrocution. Installation and servicing of this equipment must be performed by qualified personnel only. Always disconnect power at the main service panel before working on or near the load center.

  • Ensure all local and national electrical codes are followed during installation.
  • Wear appropriate personal protective equipment (PPE), including insulated gloves and safety glasses.
  • Verify that the power supply matches the load center's specifications (225A, Three Phase).
  • Do not install in wet or damp locations unless specifically rated for such environments. This unit is NEMA 1 rated for indoor use.

3. Product Overview

The Leviton LP622-BPD is a 66-space, 66-circuit indoor load center designed for residential and light commercial applications. It features a factory-installed 225 Amp main circuit breaker and tin-plated copper bussing for superior conductivity. The modern design includes a white, powder-coated finish. The enclosure and interior are included; the door is sold separately.

Key Features:

  • Easy Wiring: Revolutionary design allows rough-in wiring without circuit breakers present.
  • Superior Conductivity: Equipped with tin-plated copper bussing.
  • Organized Wiring: Notches for cable ties promote secure and neat wiring.
  • Modern Aesthetic: White, powder-coated finish.
  • High Capacity: 66 spaces for up to 66 circuits.
Leviton LP622-BPD Load Center Interior

Figure 3.1: Interior view of the Leviton LP622-BPD Load Center, showing the main breaker and circuit breaker spaces.

4. Installation and Setup

Installation of the Leviton LP622-BPD Load Center should only be performed by a qualified electrician. Follow these general steps:

  1. Mounting the Enclosure: Securely mount the load center enclosure to a suitable surface, ensuring it is level and plumb.
  2. Rough-in Wiring: Route all incoming and outgoing electrical wires into the load center. The design allows for wiring without breakers installed, simplifying the process.
  3. Connecting Main Power: Connect the main service entrance conductors to the factory-installed 225 Amp main circuit breaker.
  4. Connecting Branch Circuits: Connect the individual branch circuit wires to the appropriate terminals within the load center. Utilize the cable tie notches for organized wiring.
  5. Installing Circuit Breakers: Once wiring is complete, snap the individual circuit breakers into their designated spaces. The plug-on design ensures easy and secure installation.
Installing a Leviton Plug-on Circuit Breaker

Figure 4.1: A hand demonstrating the installation of a plug-on circuit breaker into the load center bussing.

Leviton Load Center with organized wiring

Figure 4.2: An example of a Leviton Load Center with neatly organized wiring, utilizing the integrated cable tie notches.

Optional Smart Home Integration:

The Leviton Load Center is compatible with Leviton's smart circuit breakers and whole-house energy monitor for advanced energy management and monitoring. This involves:

  1. Install the Leviton Whole House Energy Monitor.
  2. Snap in 2nd Gen Smart Circuit Breakers.
  3. Enroll Breakers in the My Leviton App.
Leviton Smart Home Integration Steps

Figure 4.3: Visual representation of the three steps for integrating the load center with Leviton's smart home ecosystem.

5. Operation

Operating the Leviton Load Center primarily involves managing the circuit breakers. Each circuit breaker controls a specific electrical circuit in your property.

  • Turning a Circuit ON/OFF: To turn a circuit on, push the breaker handle firmly to the 'ON' position. To turn it off, push the handle to the 'OFF' position.
  • Resetting a Tripped Breaker: If a circuit breaker trips (moves to a middle or 'OFF' position), it indicates an overload or fault. First, identify and resolve the cause of the trip. Then, push the breaker handle firmly to the 'OFF' position, and then back to the 'ON' position to reset it.
  • Observation Window: If an optional window door is installed, an observation window allows for at-a-glance operating status of all circuit breakers.
Leviton Load Center with observation window

Figure 5.1: Close-up view of circuit breakers within the load center, visible through an observation window in the cover.

Leviton Load Center Door Options

Figure 5.2: Comparison of a standard door and a window door option for the Leviton Load Center. Note: Door sold separately.

6. Maintenance

Regular maintenance helps ensure the longevity and safe operation of your Leviton Load Center. Always disconnect power before performing any maintenance.

  • Visual Inspection: Periodically inspect the load center for any signs of damage, loose connections, or corrosion.
  • Cleaning: Keep the load center interior and exterior clean and free from dust and debris. Use a dry, non-abrasive cloth.
  • Tighten Connections: Over time, electrical connections can loosen. Have a qualified electrician periodically check and tighten all terminal screws.
  • Breaker Testing: If your load center includes GFCI or AFCI breakers, test them monthly according to their individual instructions.

7. Troubleshooting

This section addresses common issues you might encounter with your load center.

ProblemPossible CauseSolution
Circuit breaker trips frequentlyOverloaded circuit, short circuit, or ground fault.Reduce load on the circuit. Inspect wiring and appliances for faults. If problem persists, consult an electrician.
No power to a specific circuitTripped breaker, loose connection, or faulty breaker.Check and reset the breaker. Inspect connections (with power off). If necessary, replace the breaker.
Main breaker tripsSystem-wide overload or major fault.Turn off all branch circuit breakers, then reset the main breaker. Turn on branch breakers one by one to identify the faulty circuit. If problem persists, contact a qualified electrician immediately.

For issues not covered here, or if you are unsure about any troubleshooting step, contact a qualified electrician or Leviton customer support.

8. Specifications

AttributeDetail
Model NumberLP622-BPD
BrandLeviton
Product Dimensions55.8 x 14.3 x 4 inches
Weight51 Pounds
AC Adapter Current225 Amps
MaterialCopper
Number Of Circuits66
Phase TypeThree Phase
NEMA RatingNEMA 1 (Indoor Use)

9. Warranty and Support

Leviton products are manufactured to high-quality standards. For specific warranty information, please refer to the documentation included with your purchase or visit the official Leviton website. If you require technical assistance, have questions about installation, or need to report a product issue, please contact Leviton customer support.

Leviton Customer Support:

  • Visit the Leviton Store on Amazon for product information.
  • Refer to the official Leviton website for contact details and support resources.