Pretul BOS-1-1/2SPP (27199)

Pretul BOS-1-1/2SPP Submersible Plastic Pump, 1-1/2 HP

Instruction Manual for Model BOS-1-1/2SPP (27199)

1. Introduction

Thank you for choosing the Pretul BOS-1-1/2SPP Submersible Plastic Pump. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your pump. Please read these instructions carefully before use and retain them for future reference.

This pump is designed for pumping dirty water, suitable for drainage and flood control applications. It features a robust 1-1/2 HP motor with aluminum coils, a suction base with a particle filter grille, and a capacitor for enhanced starting power.

2. Safety Information

Always observe the following safety precautions to prevent personal injury or damage to the pump:

  • Electrical Safety: Ensure the power supply matches the pump's requirements. Do not operate the pump with damaged cables or plugs. Always connect to a grounded outlet. Never touch the pump or water while it is connected to power.
  • Water Type: This pump is designed for dirty water. Do not use it for potable water, flammable liquids, corrosive chemicals, or highly abrasive materials.
  • Immersion Depth: Do not exceed the maximum immersion depth of 7 meters. Ensure the pump is fully submerged during operation to prevent overheating.
  • Temperature: Do not pump liquids hotter than 35°C (95°F).
  • Children and Pets: Keep children and pets away from the pump and the area of operation.
  • Maintenance: Always disconnect the pump from the power supply before performing any maintenance or cleaning.

3. Product Components

Familiarize yourself with the main parts of your Pretul submersible pump:

Diagram showing the components of the Pretul BOS-1-1/2SPP submersible pump, including the float switch, handle, hose adapter, and suction base.

Image 3.1: Pump Components Overview
This image illustrates the key components of the Pretul BOS-1-1/2SPP pump. Visible parts include the handle for easy transport, the float switch for automatic operation, the multi-size hose adapter, and the suction base with its integrated particle filter grille.

  • Handle (Asa): For carrying and positioning the pump.
  • Float Switch (Interruptor flotador): Automatically turns the pump on/off based on water level.
  • Hose Adapter (Adaptador para manguera): Connects to discharge hoses of 1" (25mm), 1-1/4" (32mm), and pipes of 1" (25mm), 1-1/2" (38mm).
  • Suction Base (Base de succión): Features a filter grille to prevent large particles from entering the pump.
  • Motor: 1-1/2 HP motor with aluminum coils for efficient operation.

4. Specifications

FeatureSpecification
ModelBOS-1-1/2SPP (27199)
Power1-1/2 HP
Max Flow Rate240 Liters per minute
Max Head (Height)8.5 meters
Max Immersion Depth7 meters
MaterialPlastic body with Aluminum motor coils
Power SourceElectric cable
Dimensions (L x W x H)18 x 18 x 40 cm
Weight5 Kilograms
ManufacturerTruper SA de CV
Performance curve graph showing flow rate in L/min versus head in meters for the BOS-1-1/2SPP pump.

Image 4.1: Performance Curve
This graph illustrates the relationship between the pump's flow rate (L/min) and the maximum head (height in meters) it can achieve. Use this curve to determine the pump's performance under different operating conditions.

5. Setup

  1. Unpacking: Carefully remove the pump and all accessories from the packaging. Inspect for any damage.
  2. Hose Connection: Attach a suitable discharge hose to the hose adapter. The adapter supports various hose and pipe sizes (1", 1-1/4", 1-1/2"). Ensure a secure, leak-free connection.
  3. Positioning: Place the pump on a stable, flat surface in the water to be drained. Ensure the pump is fully submerged and not resting directly on mud or debris that could block the suction base.
  4. Float Switch Adjustment: Adjust the float switch cable length to control the automatic on/off levels. A shorter cable will result in a smaller operating range (pump turns on/off with less water level change), while a longer cable allows for a wider range. Ensure the float switch can move freely without obstruction.
  5. Power Connection: Connect the pump's power cable to a grounded electrical outlet that matches the pump's voltage requirements.

6. Operating Instructions

  1. Initial Start-up: Once the pump is correctly positioned and connected, plug it into the power outlet. The pump will start automatically when the water level rises and activates the float switch.
  2. Automatic Operation: The float switch will turn the pump on when the water reaches a certain level and turn it off when the water level drops below the minimum required for operation.
  3. Manual Operation (if applicable): If your model allows for manual override, ensure the float switch is in the 'on' position or manually held up to keep the pump running continuously. Always monitor the pump during manual operation to prevent dry running.
  4. Monitoring: Periodically check the discharge flow and ensure the pump is operating smoothly. Listen for unusual noises or vibrations.
  5. Shutting Down: To stop the pump, unplug it from the power outlet. If operating automatically, it will stop when the water level drops.

Important: Avoid dry running the pump, as this can cause severe damage to the motor and seals. Ensure the pump is always fully submerged during operation.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your pump.

  • Cleaning the Suction Base: Regularly inspect and clean the particle filter grille on the suction base to prevent blockages. Disconnect power before cleaning.
  • Impeller Inspection: If the pump's performance decreases, the impeller might be clogged. Disconnect power, remove the suction base (if detachable), and clear any debris from the impeller area.
  • Storage: When not in use for extended periods, clean the pump thoroughly, drain all water, and store it in a dry, frost-free location.
  • Cable Inspection: Periodically check the power cable for any signs of wear, cuts, or damage. Replace immediately if damaged.

8. Troubleshooting

ProblemPossible CauseSolution
Pump does not startNo power supply
Float switch not activated
Motor overload
Check power connection and circuit breaker
Ensure water level is high enough to activate float switch
Disconnect power, let pump cool, check for blockages
Pump runs but no water is discharged or flow is lowSuction base or impeller clogged
Air lock
Discharge hose kinked or blocked
Disconnect power, clean suction base and impeller
Ensure pump is fully submerged and free of air pockets
Check and clear discharge hose
Pump stops unexpectedlyFloat switch deactivated (low water level)
Thermal overload protection activated
Wait for water level to rise or manually activate float switch
Disconnect power, let pump cool down, check for blockages or dry running
Excessive noise or vibrationDebris in impeller
Pump not stable
Disconnect power, clean impeller
Ensure pump is on a flat, stable surface

9. Warranty

Pretul products are manufactured to high-quality standards. This product typically comes with a manufacturer's warranty against defects in materials and workmanship. Please refer to the warranty card included in your product packaging for specific terms, conditions, and duration of the warranty. Keep your purchase receipt as proof of purchase.

10. Customer Support

If you have any questions, require technical assistance, or need to report a problem with your Pretul BOS-1-1/2SPP pump, please contact Pretul customer service. Refer to the contact information provided on the product packaging or visit the official Pretul website for support details.

For more information, you may visit the Pretul Brand Store.

Related Documents - BOS-1-1/2SPP (27199)

Preview PRETUL Submersible Deep Well Pump Manual - BOS Series
Comprehensive manual for PRETUL submersible deep well pumps (BOS series), covering technical specifications, installation, operation, maintenance, troubleshooting, and warranty information for agricultural use. Includes safety guidelines and authorized service center details.
Preview Manual de Usuario: Bomba Sumergible PRETUL BOS-1-1/2SPP para Agua Sucia
Manual completo de usuario para la bomba sumergible PRETUL modelo BOS-1-1/2SPP, diseñada para agua sucia. Incluye especificaciones técnicas, advertencias de seguridad, instrucciones de instalación, operación, mantenimiento y solución de problemas.
Preview PRETUL Submersible Pump Manual - BOS-1/2LPP & BOS-3/4LPP
Comprehensive user manual for PRETUL submersible pumps (models BOS-1/2LPP and BOS-3/4LPP), covering technical specifications, safety warnings, installation, operation, maintenance, and troubleshooting for clean water applications.
Preview PRETUL ROTO-1/2P6 Hammer Drill User Manual
This manual provides essential information for the safe operation, maintenance, and warranty of the PRETUL ROTO-1/2P6 Hammer Drill (Model 28112). Learn about its features, safety precautions, and troubleshooting.
Preview Pretul ESMA-4-1/2P2 Angle Grinder Instruction Manual
This manual provides instructions for the safe operation, maintenance, and assembly of the Pretul ESMA-4-1/2P2 angle grinder. It includes technical specifications, safety guidelines, and a list of authorized service centers.
Preview Guía de Instalación y Extracción del Broquero PRETUL BRO-1/2P
Instrucciones detalladas para instalar y extraer el broquero PRETUL BRO-1/2P. Incluye pasos, compatibilidad con taladros de 1/2" (13 mm) y datos del importador TRUPER.