Bante Instruments A120

Bante A120 Laboratory pH/ORP Meter User Manual

1. Introduction

The Bante A120 is a high-precision laboratory pH/ORP meter designed for accurate and reliable measurements in various scientific and industrial applications. This benchtop meter offers advanced features such as 1 to 5 points calibration, automatic temperature compensation, and selectable ORP measurement modes, ensuring optimal performance and ease of use.

Bante A120 Laboratory pH/ORP Meter

Figure 1: The Bante A120 Laboratory pH/ORP Meter with electrode arm.

2. Key Features

The Bante A120 meter incorporates several features to enhance measurement accuracy and user convenience:

  • 1 to 5 points calibration with automatic buffer recognition.
  • Automatic electrode diagnosis displays zero point offset and pH slope.
  • Automatic temperature compensation ensures accurate pH measurement.
  • Selectable ORP measurement, including relative and absolute modes.
  • Automatic Read function detects and locks the measurement endpoint.
  • Password protection prevents unauthorized calibration and adjustments.
  • The setup menu contains 16 options, including pH buffer group, number of calibration points, resolution, solution temperature coefficient, calibration due alarm, upper/lower limit alarm, stability criteria, interval readings, auto-power off, factory reset, etc.
Bante A120 Meter Features Icons

Figure 2: Visual representation of the Bante A120's key features.

3. Components and Accessories

The Bante A120 meter typically includes the following components:

  • Bante A120 pH/ORP Meter unit
  • E201-BNC pH Electrode
  • TP-10K Temperature Probe
  • pH Buffer Solutions (4.01, 7.00, 10.01)
  • Electrode Arm and Base Plate
  • DC 12V Power Adapter
Bante A120 Accessories

Figure 3: Included accessories for the Bante A120 meter.

Bante A120 Meter Includes Components

Figure 4: Detailed view of the components included with the Bante A120, including the pH electrode with a removable shield for easy rinsing.

4. Setup

4.1 Physical Connections

Before operating the meter, ensure all necessary components are properly connected:

  1. pH/ORP Electrode: Connect the BNC connector of the pH or ORP electrode to the BNC socket on the rear panel of the meter.
  2. Temperature Probe: Insert the jack connector of the temperature probe (TP-10K) into the dedicated jack socket.
  3. Power Adapter: Connect the DC 12V power adapter to the power socket and then plug it into a suitable power outlet.
  4. USB Interface: For data transfer or printer connection, use the USB interface.
Bante A120 Connectors

Figure 5: Rear panel connectors for the Bante A120, including BNC, Jack, USB, and Power sockets.

4.2 Initial Power On

After connecting all components, press the power button to turn on the meter. The 7-inch TFT LCD screen will display the startup sequence and then enter the measurement interface.

5. Operation

5.1 Display Overview

The Bante A120 features a 7-inch TFT LCD screen that clearly shows measurement values, status icons, setup menu, and operation guides. The display provides real-time data and intuitive navigation.

Bante A120 Display Screen

Figure 6: The Bante A120 display screen showing measurement, settings, and calibration reminder interfaces.

Bante A120 Detailed Display Examples

Figure 7: Detailed screenshots of the Bante A120 display, including measurement, stored data, settings, and calibration screens.

5.2 pH Calibration

The meter supports 1 to 5 points calibration with automatic buffer recognition. Refer to the on-screen guide for step-by-step instructions. Regular calibration ensures measurement accuracy.

5.3 pH Measurement

Place the pH electrode and temperature probe into the sample. The meter will automatically compensate for temperature variations. The Auto-Read function will detect and lock the stable measurement endpoint.

5.4 ORP Measurement

The Bante A120 allows for selectable ORP measurement modes, including relative and absolute ORP. Ensure the correct ORP electrode is connected and calibrated as per the instructions.

5.5 Settings Menu

Access the settings menu to configure various parameters such as pH buffer group, resolution, alarm limits, interval readings, and auto-power off. Password protection is available to prevent unauthorized changes.

6. Maintenance

6.1 Electrode Care

To maintain electrode performance and extend its lifespan:

  • Always keep the pH electrode bulb hydrated by storing it in a suitable storage solution or buffer.
  • Rinse the electrode with distilled water after each use.
  • The pH electrode features a removable shield for easy rinsing of the pH-sensitive glass membrane.
Bante A120 Protection Cap

Figure 8: The rubber protection cap provides protection against ingress of water and dust for the meter.

6.2 Meter Cleaning

Wipe the meter's exterior with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure no liquids enter the meter's connectors or internal components.

7. Troubleshooting

This section addresses common issues you might encounter:

  • "Calibration Due" Reminder: This indicates that the last calibration has expired. Perform a new calibration to ensure accuracy.
  • Unstable Readings: Check the electrode for damage or contamination. Ensure the sample is well-mixed and the temperature probe is correctly placed. Verify that the electrode is properly connected.
  • Electrode Error Message: The automatic electrode diagnosis feature will indicate issues such as zero point offset or slope problems. Clean or replace the electrode if necessary.
  • No Power: Ensure the power adapter is securely connected to both the meter and the power outlet. Check the power source.

8. Specifications

Bante A120 Detailed Specifications Table

Figure 9: Detailed technical specifications for the Bante A120 meter.

ParameterSpecification
pH Range-2.000 to 20.000 pH
pH Resolution0.001 / 0.01, selectable
pH Accuracy±0.002 pH
pH Calibration1 to 5 points
pH Buffer OptionsUSA / NIST / DIN / 5 custom buffers
ORP Range-2000.0 to 2000.0 mV
ORP Resolution0.1 mV
ORP Accuracy±0.2 mV
ORP Calibration1 point
Temperature Range0 to 105°C / 32 to 221°F
Temperature Resolution0.1°C / °F
Temperature Accuracy±0.5°C / ±0.9°F
Temperature Compensation0 to 100°C / 32 to 212°F, manual or automatic
Data Storage1000 sets
Power SupplyDC 12V power adapter
Product Dimensions240 × 220 × 80 mm / 9.4 × 8.6 × 3.1 in
Product Weight1.7 kg / 3.7 lb

9. Warranty and Support

The Bante A120 Laboratory pH/ORP Meter comes with a standard manufacturer's warranty against defects in materials and workmanship. Please refer to the warranty card included with your product for specific terms and conditions.

For technical support, service, or inquiries, please contact Bante Instruments customer service through their official website or the contact information provided in your product packaging. When contacting support, please have your model number (A120) and purchase details ready.

© 2023 Bante Instruments. All rights reserved.