1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your Yale 5500-0001-60 Door Closer. Please read these instructions carefully before beginning installation to ensure proper function and safety. The Yale 5500-0001-60 door closer provides controlled and efficient door closing for various applications. This reliable door closer is designed to meet diverse user requirements.

Image 1: Yale 5500-0001-60 Door Closer with Standard Arm, Silver
2. Product Overview
The Yale 5500-0001-60 Door Closer is engineered for durability and reliable performance. Key features include:
- Mounts on doors up to 1250 mm wide and weighing up to 100 kg.
- Features a compact and lightweight die-cast aluminum rack and pinion mechanism with a robust arm.
- Tested for up to 500,000 opening and closing cycles for maximum durability.
- Force 4. CE EN 1154 certified for fire doors.
- Suitable for both left-hand and right-hand opening doors.
- Hydraulic closing mechanism with constant thermal viscosity.
- Features dual adjustment for closing speed and final snap, controlled by two screws without disassembly.
- Provides door control for openings up to 180°.
- Suitable for interior use on wooden, metal, and fire-rated doors.

Image 2: Key features of the Yale 5500-0001-60 Door Closer
3. Package Contents
Verify that all components are present before beginning installation:
- Door Closer Body
- Standard Arm Assembly
- Mounting Instructions
- Fasteners (screws, etc.)

Image 3: Contents of the Yale 5500-0001-60 Door Closer package
4. Setup and Installation
The Yale 5500-0001-60 door closer is designed for surface mounting and is suitable for both left-hand and right-hand opening doors. It can be installed on wooden, metal, and fire-rated doors for interior use.
4.1 Pre-Installation Checks
- Ensure the door closer is appropriate for your door's width (up to 1250 mm) and weight (up to 100 kg).
- Confirm that the door and frame are structurally sound to support the door closer.
- Gather necessary tools: drill, screwdriver, measuring tape, pencil, level.
4.2 Mounting the Door Closer
- Refer to the included mounting instructions for specific drilling templates and dimensions.
- Mark the drilling points on the door and door frame according to the template.
- Drill pilot holes at the marked locations.
- Attach the door closer body to the door or frame using the provided fasteners. Ensure it is level and securely fastened.
- Assemble the standard arm and attach it to the door closer body and the door frame, following the instructions for your specific door swing (left or right).
- Ensure all screws are tightened securely, but do not overtighten.
5. Operating Instructions
The Yale 5500-0001-60 door closer features adjustable closing speed and final snap to customize door operation.
5.1 Adjusting Closing Speed and Final Snap
- Locate the two adjustment screws on the door closer body. These screws control the hydraulic fluid flow.
- One screw typically controls the main closing speed (from fully open to approximately 15 degrees from closed).
- The second screw controls the final snap or latching speed (the last 15 degrees of closing).
- To increase the speed, turn the screw counter-clockwise in small increments (e.g., a quarter turn).
- To decrease the speed, turn the screw clockwise in small increments.
- After each adjustment, test the door's closing action to achieve the desired speed and latching force.
- Avoid turning the screws out too far, as this can release hydraulic fluid and damage the unit.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your door closer.
- Periodic Inspection: Annually inspect the door closer and arm assembly for any signs of wear, damage, or loose fasteners.
- Cleaning: Wipe the door closer body and arm with a soft, damp cloth to remove dust and grime. Avoid abrasive cleaners.
- Lubrication: The internal mechanism is factory-lubricated and sealed. No additional lubrication is required.
- Adjustment Check: Periodically check the closing and latching speeds and readjust if necessary due to environmental changes or heavy use.
7. Troubleshooting
If you encounter issues with your door closer, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Door closes too fast/slow | Incorrect speed adjustment | Adjust the closing speed and/or latching speed screws as described in Section 5.1. |
| Door does not latch properly | Latching speed too slow or insufficient force | Increase the latching speed using the appropriate adjustment screw. Ensure the door closer is correctly sized for the door. |
| Door closer leaks oil | Damaged seals or overtightened/removed adjustment screws | Do not attempt to repair. Contact customer support for replacement. Ensure adjustment screws are not fully removed. |
| Excessive noise during operation | Loose fasteners or worn components | Check and tighten all mounting screws. Inspect the arm assembly for wear. |
8. Specifications
| Specification | Detail |
|---|---|
| Brand | Yale |
| Model Number | 5500-0001-60 |
| Product Dimensions (L x W x H) | 20.6 x 4 x 5.5 cm |
| Item Weight | 1.8 Kilograms |
| Material | Aluminum |
| Color | Silver |
| Style | Non-hold open |
| Size | Series 5500 |
| Maximum Door Width | 1250 mm |
| Maximum Door Weight | 100 kg |
| Durability | Tested up to 500,000 cycles |
| Force | 4 |
| Certifications | CE EN 1154 (for fire doors) |
| Recommended Use | Interior use on wooden, metal, and fire-rated doors |
| Country of Origin | China |
9. Warranty and Support
For warranty information or technical support, please refer to the documentation provided with your purchase or visit the official Yale website. Information regarding spare parts availability is currently unavailable.