1. Introduction
Thank you for choosing the HORIGEN Double Wearable Breast Pump. This manual provides essential information for the safe and effective use, maintenance, and troubleshooting of your breast pump. Please read these instructions thoroughly before first use and retain them for future reference.
2. Product Overview
The HORIGEN Double Wearable Breast Pump is designed for convenient, hands-free breast milk expression. Its compact and wireless design allows for discreet use at home, in the office, or while traveling.
Key Features:
- Wearable and Hands-Free: Designed to fit discreetly within a nursing bra.
- Dual Pumping Modes: Features a Stimulation Mode to initiate milk flow and an Expression Mode for efficient pumping.
- Five Suction Levels: Adjustable suction intensity to suit individual comfort and milk flow.
- Anti-Backflow System: Prevents milk contamination and leakage.
- Food-Grade Silicone Components: Ensures safety and comfort during use.
- Low Noise Operation: Operates at less than 50 dB to minimize disturbance.
- Easy Assembly and Cleaning: Consists of only 5 parts for quick setup and maintenance.
- Integrated Milk Collection Bottle: 150ml capacity with clear measurement markings.
- Rechargeable Battery: 1300 mAh capacity with Type-C charging, providing approximately 120 minutes of use per charge.
Included Components:
- Pump Motor (x2)
- 25mm Breast Shield (x2)
- 17mm Flange Insert (x2)
- 21mm Flange Insert (x2)
- Diaphragm (x2)
- Valve (x2)
- Linker with Silicone Ring (x2)
- Bottle with Lid (x2)
- Bra Adjustment Buckle (x2)
- Type-C Charging Cable (x2)
- Extra Silicone Ring (x10)
- Extra Valve (x2)
- Instruction Manual (x1)

Image: Overview of the HORIGEN Double Wearable Breast Pump, showing the two pump units and the product packaging.
3. Safety Information
- Always wash your hands thoroughly before handling the pump parts and before expressing milk.
- Ensure all pump parts that come into contact with breast milk are clean and sterilized before each use.
- Do not immerse the pump motor unit in water or other liquids.
- Keep the pump and its accessories out of reach of children.
- Use only the provided Type-C charging cable and a compatible power adapter.
- Inspect all components regularly for wear or damage. Replace any damaged parts immediately.
- Discontinue use and consult a healthcare professional if you experience pain or discomfort during pumping.
- This product is for personal use and should not be shared.
4. Setup
4.1 Charging the Pump
- Connect the Type-C charging cable to the charging port on the pump motor.
- Plug the other end of the cable into a suitable USB power adapter (not included).
- The indicator light will show charging status. A full charge takes approximately 120 minutes.
- Disconnect the charger once fully charged.
4.2 Assembly
The pump consists of 5 main parts for assembly:
- Insert the valve securely into the bottom of the linker.
- Place the diaphragm onto the top of the linker, ensuring a tight seal.
- Attach the assembled linker and diaphragm to the breast shield.
- Screw the milk collection bottle onto the bottom of the breast shield assembly.
- Align the pump motor with the top of the breast shield and press down firmly until it clicks into place.

Image: Exploded view of the pump components, highlighting the 25mm breast shield, 17mm and 21mm flange inserts, and the 150ml collection bottle.
4.3 Flange Selection
The pump includes a 25mm breast shield and 17mm, 21mm silicone flange inserts. Choose the flange size that best fits your nipple for optimal comfort and milk expression. Your nipple should move freely within the tunnel without excessive rubbing.
5. Operating Instructions
5.1 Wearing the Pump
- Place the assembled pump unit inside your nursing bra, ensuring the breast shield is centered over your nipple.
- Adjust your bra to hold the pump securely and comfortably against your breast. Use the included bra adjustment buckle if needed to achieve a snug fit.

Image: A user demonstrating the discreet, hands-free nature of the wearable breast pump while engaged in an activity.
5.2 Powering On and Mode Selection
- Press and hold the power button on the pump motor to turn it on.
- The pump will automatically start in Stimulation Mode (fast and shallow suction) for 2 minutes to help initiate milk let-down.
- After 2 minutes, it will automatically switch to Expression Mode (slow and deep suction). You can also manually switch between modes at any time by pressing the mode button.

Image: Visual representation of the two pumping modes: Stimulation Mode (fast, shallow) and Expression Mode (slow, deep).
5.3 Adjusting Suction Levels
- Use the '+' and '-' buttons on the pump motor to increase or decrease the suction intensity. There are 5 adjustable levels.
- Select a suction level that feels comfortable and effectively expresses milk. Avoid setting the suction too high, as this can cause discomfort or injury.
5.4 Pumping Session
- Pump until your breasts feel empty or milk flow significantly slows. The recommended optimal breast pumping volume is 120 ml per session. The maximum capacity of the collection bottle is 150 ml.
- To turn off the pump, press and hold the power button.

Image: The breast pump operating quietly, indicated by a sleeping baby, demonstrating its low noise level (less than 50dB).
6. Cleaning and Maintenance
Proper cleaning and maintenance are crucial for hygiene and the longevity of your breast pump.
6.1 Disassembly for Cleaning
After each use, carefully disassemble all parts that come into contact with breast milk: the breast shield, flange insert (if used), linker, diaphragm, valve, and milk collection bottle.
6.2 Cleaning Instructions
- Wash: Rinse all disassembled parts under cold running water to remove any milk residue. Then, wash them in warm, soapy water using a mild dish soap. Use a soft brush to clean hard-to-reach areas.
- Rinse: Rinse thoroughly under clean running water to remove all soap residue.
- Sanitize: For initial use and at least once daily, sanitize the parts. This can be done by boiling them in water for 5 minutes or using a steam sterilizer.
- Dry: Air dry all parts on a clean drying rack. Ensure all components are completely dry before reassembly or storage to prevent mold or bacterial growth.
- Note: The pump motor unit should only be wiped clean with a damp cloth. Do not wash it under running water or immerse it. The pump parts are not dishwasher-safe.
6.3 Storage
Store the clean and dry pump components in a clean, dry place away from direct sunlight and extreme temperatures.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No suction or weak suction |
|
|
| Milk leakage |
|
|
| Pump not turning on |
|
|
| Pain or discomfort during pumping |
|
|
8. Specifications
| Feature | Specification |
|---|---|
| Model Number | HNR-US-2249BS1 |
| Brand | HORIGEN |
| Material | Silicone |
| Power Source | Battery Powered |
| Battery Capacity | 1300 mAh |
| Charging Port | Type-C |
| Charging Time | Approx. 120 minutes |
| Battery Life | Approx. 120 minutes |
| Noise Level | Less than 50 dB |
| Milk Bottle Capacity | 150 ml (5 oz) |
| Breast Shield Size | 25mm (with 17mm/21mm inserts) |
| Product Dimensions | 12.7 x 2.54 x 10.16 cm (per unit) |
| Item Weight | 0.65 Kilograms (total for two units) |
| Dishwasher Safe | No |
9. Warranty and Support
For warranty information or technical support, please refer to the warranty card included with your product or contact HORIGEN customer service through the retailer where the product was purchased. Please have your model number (HNR-US-2249BS1) and purchase date available when contacting support.