AEGISLINK SC200

AEGISLINK Smoke and Carbon Monoxide Detector

Model: SC200 User Manual

Reliable Home Protection You Can Trust

1. Product Overview

The AEGISLINK SC200 is a combination smoke and carbon monoxide alarm designed to provide comprehensive home safety. It features long-lasting sensors and components, offering a lifespan of up to 10 years. The device includes a replaceable 3-year lithium battery for convenience.

An informative LCD displays real-time carbon monoxide (CO) concentrations and battery power, activating when tested or when CO levels reach an alarm threshold. With a detection range of 215–430 sq. ft (20–40 m²), this light and thin unit ensures broad coverage.

Equipped with both a photoelectric smoke sensor and an electrochemical CO sensor, it delivers high consistency and reliability for dual detection and protection. The alarm emits a loud tone, over 85 dB at 10 ft (3 m), to effectively alert occupants. Installation is effortless with included screws and anchor plugs.

Official product overview video for the AEGISLINK Smoke and Carbon Monoxide Detector SC200.

2. Package Contents

  • 1 x AEGISLINK Smoke and Carbon Monoxide Detector SC200
  • 1 x CR123A Replaceable Battery
  • 1 x Mounting Bracket
  • 1 x Parts Kit (screws and anchor plugs)
  • 1 x User Manual

3. Safety Information and Warnings

WARNING: This alarm should be installed by a competent person.

ALARMS SHOULD NOT BE USED AS A SUBSTITUTE FOR PROPER INSTALLATION, USE AND MAINTENANCE OF FUEL BURNING APPLIANCES INCLUDING APPROPRIATE VENTILATION AND EXHAUST SYSTEMS.

To prevent injury, this device should be securely attached to the ceiling or wall in accordance with the installation instructions.

Batteries should not be exposed to excessive heat such as direct sunlight, fire, etc.

Locations to Avoid:

  • Near large metal surfaces and/or bundles of wire.
  • Near fluorescent lights, amateur radios, electrical equipment, or other devices that may transmit an RF signal, as electronic "noise" may cause nuisance alarms.
  • Do not install in garages, kitchens, furnace rooms, or bathrooms. Do not install within 5 ft (1.5 m) of cooking appliances.
  • Do not install within 3 ft (0.9 m) of the following: The door to a kitchen, or a bathroom that contains a tub or shower, forced air supply ducts used for heating or cooling, ceiling or whole house ventilating fans, or other high air flow areas.
  • Avoid excessively dusty, dirty, or greasy areas. Dust, grease, or household chemicals can contaminate the alarm sensors, causing the alarm to not operate properly.
  • Place the alarm where drapes or other objects will not block the sensors. Smoke and CO must be able to reach the sensors to accurately detect these conditions.
  • Do not install in peaks of vaulted ceilings, 'A' frame ceilings, or gabled roofs.
  • Keep out of damp and humid areas.
  • Do not place in direct sunlight and keep out of insect-infested areas. Extreme temperatures will affect the sensitivity of the smoke/CO alarm.
  • Do not install in areas where the temperature is colder than 40°F (4.4°C) or hotter than 100°F (37.8°C), such as garages and unfinished attics.
  • Do not install in areas where the relative humidity (RH) is above or lower than 10%. Place away from doors and windows that open to the outside.
  • Smoke alarms are not to be used with detector guards unless the combination (alarm and guard) has been evaluated and found suitable for that purpose.

4. Installation

The AEGISLINK SC200 detector is designed for easy installation on ceilings or walls. Follow these steps for proper mounting:

  1. Use the mounting bracket to mark the screw holes on the ceiling or wall.
  2. Drill holes at the marked points using an appropriately sized drill bit.
  3. Insert the anchor plugs and screw the mounting bracket using the provided screws.
  4. Attach the alarm to the mounting bracket and turn it clockwise to lock the alarm securely.
  5. After installation, test the alarm as described in the 'Operating Instructions' section.

Installation Positioning Guidelines:

  • Prioritize installing smoke alarms in bedrooms and walkways to ensure alarms are audible in all sleeping areas. In homes with multiple bedrooms, install an alarm in every bedroom.
  • If installing only one smoke alarm, place it near all bedrooms where possible, avoiding basements or furnace rooms.
  • Install an alarm above the stairway and on every floor of the house.
  • For optimal smoke detection, install the alarm in the middle of the ceiling where possible, as smoke and heat spread horizontally after rising. Ensure it's at a minimum distance from corners.
  • If ceiling installation is not possible, install the alarm on a wall at a distance of 20 inches (50 cm) from the corners of the room.
AEGISLINK SC200 Smoke and Carbon Monoxide Detector

Main view of the AEGISLINK SC200 detector.

Compact design of the AEGISLINK SC200 detector with dimensions

Compact design of the AEGISLINK SC200 detector, showing its dimensions (4.9 in x 4.9 in x 1.4 in).

5. Setup and Interconnection (for Multi-Packs)

The wireless interlinked alarms in a multi-pack are pre-interconnected. If you purchase more than one multi-pack, you will need to connect them to form a single interlinked network. A maximum of 24 wireless alarms can be interconnected on the same network. This model can only be interconnected with other AEGISLINK wireless interlinked alarms.

Interconnection Steps:

  1. To ensure all alarms enter the same interlinked network, work with only 2 units at a time: one unit in pairing mode and the other in searching mode.
  2. Press the pinhole pairing button on the unit you want to set to pairing mode.
  3. Hold down the pinhole pairing button on the unit you want to set to searching mode.
  4. The alarm will enter searching mode or pairing mode for 60 seconds with the LED flashing red.
  5. After 60 seconds, repeat steps 2 and 3 to connect the alarms.
  6. If needed, press the pinhole pairing button once while the alarm is in searching or pairing mode, and the LED will stop flashing red, exiting pairing mode to normal status.
  7. Test all wireless alarms to ensure they are interconnected before final installation.
AEGISLINK SC200 providing 2-in-1 protection against smoke and carbon monoxide

The AEGISLINK SC200 offers 2-in-1 protection against both smoke and carbon monoxide.

AEGISLINK Combination Smoke and Carbon Monoxide Alarm 2-in-1 Protection

Banner highlighting the 2-in-1 protection of the AEGISLINK Combination Smoke and Carbon Monoxide Alarm.

6. Operating Instructions

The SC200 features an informative LCD that displays real-time CO concentrations and battery levels. The device activates its display when tested or when CO levels reach an alarm threshold to conserve power.

LED Indicators and Audible Alarm:

ModeLCD DisplayLED IndicatorAudible AlarmRemarks
Standby Mode--Flashes green once every 60 secondsNoneNormal operation
Smoke Alarm--Flashes red with 3 long beeps every 4 seconds3 long beeps every 4 secondsSmoke detected
CO AlarmCO ppm valueFlashes red with 4 quick beeps every 5.8 seconds4 quick beeps every 5.8 secondsCO detected
Silence Mode--NoneNoneSilence time of around 9 minutes
Low BatteryLbFlashes yellow with 1 beep every 60 seconds1 beep every 60 secondsReplace the unit immediately
FaultErrFlashes yellow with 2 beeps every 60 seconds2 beeps every 60 secondsClean the alarm cover and vents with a soft brush once a month to remove dust and dirt.

Test/Silence Button:

The test/silence button allows you to verify the alarm's functionality and temporarily silence alarms. Press the button to initiate a test. The alarm will ring with 2 long beeps followed by 4 quick beeps. The LED will flash red during the audible signal. After testing, the alarm will automatically enter standby mode. For interconnected units, the initiating unit will beep continuously with the LED flashing red, and other units will receive the signal after 5 seconds, then beep continuously with red and green LEDs. Release the button to stop testing. Testing should be completed within 3 minutes.

Informative LCD display of AEGISLINK SC200 showing CO levels and battery

Informative LCD display showing CO levels and battery status.

AEGISLINK SC200 with informative LCD display

The informative LCD display provides clear readings.

AEGISLINK SC200 LED indicators for Power, Alarm, and Fault

LED indicators show power (green), alarm (red), and fault/low battery (yellow) status.

User pressing the Test/Silence button on AEGISLINK SC200

The Test/Silence button allows for easy testing and temporary silencing of the alarm.

AEGISLINK SC200 emitting loud alarm tone

The loud alarm tone ensures effective alerting.

7. Maintenance

Battery Replacement:

The SC200 uses a replaceable 3-year lithium battery (CR123A 3V). To replace the battery:

  1. Detach the alarm from the mounting bracket by twisting counterclockwise.
  2. Pull the battery removal tab to remove the old battery.
  3. Install a new CR123A 3V lithium battery, ensuring correct polarity markings.
  4. Test the alarm after battery replacement.
  5. Mount the alarm back onto the mounting bracket by twisting clockwise to lock it.

Cleaning:

Clean the alarm cover and vents with a soft brush once a month to remove dust and dirt. This helps maintain optimal performance and prevents nuisance alarms.

Replacing the battery in AEGISLINK SC200

The replaceable lithium battery ensures long-term operation.

Hand replacing battery in AEGISLINK SC200

Easy battery replacement process.

8. Troubleshooting

  • Fault Indication: If the LED flashes yellow with 2 beeps every 60 seconds, it indicates a fault. Clean the alarm cover and vents. If the issue persists, the unit may need replacement.
  • Low Battery Indication: If the LED flashes yellow with 1 beep every 60 seconds, the battery is low. Replace the battery immediately.
  • No Audible Test Signal: If the alarm fails to produce an audible test signal during a test, refer to the troubleshooting guide in the full user manual.

WARNING: Never use an open flame to test this device.

9. Technical Specifications

FeatureSpecification
BrandAEGISLINK
ModelSC200
Power SourceBattery Powered (1 x CR123A Lithium Battery)
Sensor TypePhotoelectric (Smoke), Electrochemical (CO)
Lifespan10 Years
Detection Coverage215-430 sq. ft (20-40 m²)
Alarm LoudnessOver 85 dB at 10 ft (3 m)
Product Dimensions1.4"D x 4.9"W x 4.9"H
Item Weight0.48 Pounds (7.7 ounces)
ColorWhite
MaterialFlame Retardant ABS
Installation MethodScrew-In

10. Warranty and Support

The AEGISLINK SC200 comes with a 60-day return policy, a 5-year warranty, and lifetime technical support. For any inquiries or assistance, please contact AEGISLINK customer service.

Related Documents - SC200

PreviewAegislink Combination Smoke and Carbon Monoxide Alarm User Manual SC200/SC220/SC240
Comprehensive user manual for the Aegislink SC200, SC220, and SC240 combination smoke and carbon monoxide alarms. Includes installation, operation, safety, maintenance, and troubleshooting information.
PreviewAegislink Combination Smoke and Carbon Monoxide Alarm User Manual (SC200/SC220/SC240)
This user manual provides essential information for the installation, operation, and maintenance of the Aegislink Combination Smoke and Carbon Monoxide Alarm (Models SC200, SC220, SC240). It covers product features, safety warnings, installation guidelines, troubleshooting, and technical specifications to ensure effective protection against smoke and carbon monoxide hazards in residential settings.
PreviewAegislink APZ-iR Smoke & Carbon Monoxide Alarm User Manual
This comprehensive user manual provides detailed instructions for the Aegislink APZ-iR Replaceable Battery Smoke & Carbon Monoxide Alarm. It covers product features, technical specifications, installation, setup, daily maintenance, troubleshooting, and important safety information for home use. Includes guidance on Wi-Fi connectivity and app features.
PreviewAEGISLINK Wireless Interlinked Combination Smoke and Carbon Monoxide Alarm User Manual
Comprehensive user manual for the AEGISLINK Wireless Interlinked Combination Smoke and Carbon Monoxide Alarm (Models SC-RF200/SC-RF220). Learn about product features, safety information, setup, interconnection, alarm testing, installation positioning, battery replacement, troubleshooting, and maintenance.
PreviewAegislink Plus Smoke and CO Alarm User Manual
Comprehensive user manual for the Aegislink Plus Smoke and Carbon Monoxide Alarm, covering installation, testing, maintenance, troubleshooting, and safety information.
PreviewAegislink S500 Photoelectric Smoke Alarm User Manual
Comprehensive user manual for the Aegislink S500 Photoelectric Smoke Alarm. Learn about installation, operation, safety features, maintenance, and troubleshooting.