Dasqua 1804-1055

Dasqua 1804-1055 2-in-1 Laser Tape Measure User Manual

Model: 1804-1055

1. Introduction

This manual provides comprehensive instructions for the safe and effective use of your Dasqua 1804-1055 2-in-1 Laser Tape Measure. This device combines a traditional 5-meter tape measure with a 30-meter laser distance meter, featuring an OLED display for clear readings and USB charging capability. Please read this manual thoroughly before operating the device and retain it for future reference.

2. Safety Information

WARNING: This product contains a Class 2 laser. Improper use can result in hazardous radiation exposure. Always adhere to the following safety guidelines:

3. Product Overview

3.1 Components and Controls

Familiarize yourself with the main components and control buttons of your Dasqua 2-in-1 Laser Tape Measure.

Dasqua 1804-1055 Laser Tape Measure with labeled components and buttons

Image: Diagram showing the Dasqua 1804-1055 device with labels for the OLED display, laser emission point, USB charging port, tape measure, lock button, and control buttons.

3.2 Control Buttons

Close-up of Dasqua 1804-1055 control buttons

Image: Close-up view of the control panel on the Dasqua 1804-1055, showing the FUNC/UNITS, +/-, DIST, and CLEAR/OFF buttons.

4. Setup

4.1 Charging the Device

The Dasqua 1804-1055 is equipped with a built-in Li-ion 3.7V rechargeable battery. Before first use, ensure the device is fully charged.

Dasqua 1804-1055 with USB charging port

Image: Side view of the Dasqua 1804-1055 showing the micro-USB charging port.

  1. Locate the USB charging port on the side of the device.
  2. Connect the provided USB cable to the device and to a standard USB power adapter (not included) or a computer USB port.
  3. The OLED display will indicate charging status.
  4. Once fully charged, disconnect the USB cable.

A full charge provides approximately 2000 measurements.

4.2 Powering On/Off

5. Operating Instructions

5.1 Using the Tape Measure

The integrated 5-meter tape measure functions like a standard tape measure.

Close-up of Dasqua 1804-1055 tape measure

Image: Close-up view of the 2.5cm wide tape measure extending from the Dasqua 1804-1055 device, showing metric markings.

  1. Pull the tape blade out to the desired length.
  2. To lock the tape in place, slide the lock button forward.
  3. To retract the tape, slide the lock button backward and gently guide the tape back into the housing.

5.2 Using the Laser Measure

The laser measure provides quick and accurate digital distance measurements up to 30 meters.

Dasqua 1804-1055 emitting a red laser beam

Image: The Dasqua 1804-1055 device with a visible red laser beam extending from its front, indicating active laser measurement.

Single Distance Measurement

  1. Power on the device.
  2. Point the laser emission point towards the target.
  3. Press the DIST button once to activate the laser. A red laser dot will appear on the target.
  4. Press the DIST button again to take the measurement. The distance will be displayed on the OLED screen.

Continuous Measurement (Tracking)

  1. Power on the device.
  2. Press the FUNC/UNITS button until the continuous measurement icon (often a moving line or similar) appears on the display.
  3. Press the DIST button once to start continuous measurement. The display will update in real-time as you move the device.
  4. Press the DIST button again to stop continuous measurement and hold the last reading.

Changing Measurement Units

To switch between meters (m), feet (ft), and inches (in):

Setting Measurement Reference Point

The device can measure from its front edge or its rear edge. This is typically indicated by an icon on the display.

Addition and Subtraction of Measurements

The device supports basic arithmetic operations for measurements.

  1. Take the first measurement using the DIST button.
  2. Press the +/- button once for addition (+) or twice for subtraction (-). The corresponding symbol will appear on the display.
  3. Take the second measurement. The result of the operation will be displayed.
  4. To clear the calculation, press CLEAR/OFF.

6. Maintenance

7. Troubleshooting

ProblemPossible CauseSolution
Device does not power on.Low battery.Charge the device using the USB cable.
Inaccurate laser measurements.Dirty laser lens; unstable measurement surface; incorrect reference point.Clean the laser lens; ensure a stable measurement; verify reference point setting.
Laser does not activate.Device in incorrect mode; low battery.Ensure device is powered on and not in a non-laser mode; charge battery.
OLED display is dim or blank.Low battery; device powered off.Charge the device; power on the device.

8. Specifications

Detailed technical specifications for the Dasqua 1804-1055 2-in-1 Laser Tape Measure.

Dasqua 1804-1055 Laser Tape Measure technical specifications diagram

Image: Detailed diagram of the Dasqua 1804-1055 with a list of technical specifications including measurement range, accuracy, laser class, operating conditions, and battery life.

FeatureSpecification
Laser Measuring Range0.05 - 30 meters
Tape Measure Length5 meters
Measuring Accuracy+/- 3mm
Laser ClassClass 2
Laser Type620-690nm, <1mW
Operating Temperature0°C - 40°C (32°F - 104°F)
Storage Temperature-20°C - 70°C (-4°F - 158°F)
Display TypeOLED, Multi-line (2 lines), White on Black
Battery TypeLi-ion 3.7V
Battery LifeApprox. 2000 measurements
Laser Auto-Off30 seconds
Power Auto-Off90 seconds
Tape Width2.5 cm
ChargingUSB charging capability
Product Dimensions6 x 5 x 3 inches (approximate)
Item Weight2 pounds (approximate)

9. Warranty and Support

Dasqua products are manufactured under strict quality control. This product is inspected and approved for sale by Dasqua quality control centers.

Dasqua Warranty Letter and Instruction Manual

Image: The Dasqua 1804-1055 device alongside a "Warranty Letter" and an instruction manual, indicating product quality assurance.

Dasqua takes responsibility for the quality of the product, providing a 1-year warranty against defects. Parts found to be defective may be repaired or replaced at Dasqua's sole discretion. This warranty does not apply to any product which has been subject to misuse, abuse, improper application, or which has been altered or repaired by unauthorized personnel.

For warranty claims or technical support, please contact your authorized Dasqua dealer or visit the official Dasqua website for contact information.

Related Documents - 1804-1055

Preview Dasqua Digital Angle Ruler Product Instructions
Comprehensive instructions for the Dasqua Digital Angle Ruler, covering functions, features, maintenance, troubleshooting, and operating modes like NORMAL, CROWN, and CUS.
Preview Dasqua Digital Caliper User Manual and Specifications
Comprehensive guide for the Dasqua Digital Caliper, covering usage instructions, safety guidelines, specifications, troubleshooting, and disposal information. Includes details on battery installation and maintenance.
Preview Dasqua IP67 Digital Dial Caliper Product Instructions
Comprehensive instructions for the Dasqua IP67 Digital Dial Caliper, covering performance guidelines, disposal, troubleshooting, specifications, and operation instructions.
Preview Dasqua Vernier/Dial Caliper Instruction Manual
Instruction manual for Dasqua Vernier and Dial Calipers, covering structures, reading measurements, common usage, special caliper usage, precautions, and troubleshooting.
Preview Digital Indicating Gauge with Linear Encoder - Safety and Technical Information
Safety instructions, handling guidelines, and technical specifications for the DASQUA Digital Indicating Gauge with Linear Encoder (Models DQ-25001, DQ-25002).
Preview Dasqua IP67 Digital Caliper Product Instructions and Usage Guide
Comprehensive product instructions for the Dasqua IP67 Digital Caliper. This guide covers performance guidelines, safety precautions, detailed specifications, usage instructions, battery replacement, troubleshooting, and proper disposal methods for accurate and safe operation.