Dekain ELPLP31, V13H010L31, 830P, 835P, EMP-830, EMP-830P, EMP-835, EMP-835P

Dekain Projector Lamp Replacement Manual

For Epson Powerlite 830P, 835P, EMP-830, EMP-830P, EMP-835, EMP-835P (ELPLP31)

1. Introduction

This manual provides essential instructions for the safe and effective replacement of your projector lamp. The Dekain ELPLP31 lamp module is designed for use with specific Epson projector models, ensuring performance comparable to the original lamp.

Please read this manual thoroughly before attempting installation or operation. Keep it for future reference.

2. Safety Information

WARNING: Projector lamps operate at high temperatures and contain mercury. Improper handling can result in injury or damage.

  • Always disconnect the projector from the power outlet and allow it to cool completely (at least 60 minutes) before attempting lamp replacement.
  • Do not touch the glass part of the lamp with bare hands. Oils from your skin can cause hot spots and reduce lamp life.
  • Wear protective gloves when handling the lamp module.
  • Dispose of old lamps according to local regulations for mercury-containing products. Do not discard with regular household waste.
  • Never operate the projector with the lamp cover removed.

3. Compatibility

This Dekain ELPLP31 projector lamp replacement is compatible with the following Epson projector models:

  • Epson Powerlite 830P
  • Epson Powerlite 835P
  • Epson EMP-830
  • Epson EMP-830P
  • Epson EMP-835
  • Epson EMP-835P

Manufacturer Part Numbers: ELPLP31 / V13H010L31

4. Package Contents

Your package should contain:

  • 1 x Dekain ELPLP31 Projector Lamp Module with Housing

Inspect the contents upon receipt. If any items are missing or damaged, contact customer support immediately.

5. Installation Instructions

Follow these steps carefully to replace the projector lamp:

  1. Prepare the Projector: Ensure the projector is turned off and unplugged from the power source. Allow it to cool down for at least 60 minutes to prevent burns.
  2. Locate the Lamp Cover: Refer to your projector's user manual to identify the lamp cover location. It is typically secured by one or more screws.
  3. Remove the Lamp Cover: Using a screwdriver (Step 1 in diagram), carefully loosen the screw(s) securing the lamp cover (Step 2 in diagram). Remove the cover.
  4. Loosen Lamp Screws: The lamp module itself is usually secured by one or two screws. Loosen these screws (Step 3 in diagram).
  5. Remove the Old Lamp: Carefully grasp the handle or designated removal point on the old lamp module and gently pull it out of the projector (Step 4 in diagram). Avoid forcing it.
  6. Install the New Lamp: Align the new Dekain lamp module with the slot in the projector. Gently push it in until it is firmly seated. Do not force it.
  7. Secure the New Lamp: Tighten the screw(s) that secure the lamp module.
  8. Replace the Lamp Cover: Reattach the lamp cover and tighten its screw(s).
  9. Reset Lamp Timer: Plug the projector back in and turn it on. Navigate to the projector's menu and reset the lamp timer. Consult your projector's manual for specific instructions on resetting the lamp timer.
Diagram showing steps to replace a projector lamp

Image Description: An exploded diagram illustrating the process of replacing a projector lamp. It shows a projector with its top panel removed, revealing the lamp compartment. Numbered steps indicate using a screwdriver to remove screws (1, 3), lifting a cover (2), and then pulling out the old lamp module (4).

Front view of the Dekain ELPLP31 projector lamp moduleSide view of the Dekain ELPLP31 projector lamp module

Image Description: Two images showing different views of the Dekain ELPLP31 projector lamp module. The first image displays a front-angled view of the black plastic housing with the Philips UHP bulb visible inside. The second image shows a side view, highlighting the ventilation grilles and connectors of the lamp module.

6. Operating Guidelines

To maximize the life and performance of your new lamp:

  • Proper Shutdown: Always allow the projector to complete its cool-down cycle before unplugging it or turning it off at the main power switch. Abrupt shutdowns can shorten lamp life.
  • Ventilation: Ensure the projector has adequate ventilation. Do not block air vents.
  • Avoid Frequent On/Off Cycles: Turning the projector on and off frequently can stress the lamp. If you need to pause viewing for a short period, it is often better to leave the projector on.
  • Environmental Conditions: Operate the projector in a clean, relatively dust-free environment with stable room temperature.

7. Maintenance

Regular maintenance helps maintain projector performance and lamp longevity:

  • Clean Air Filter: Periodically clean or replace the projector's air filter as recommended by the projector manufacturer. A clogged filter can lead to overheating and reduced lamp life.
  • Dust Removal: Gently clean the projector's exterior and vents with a soft, dry cloth. Avoid using abrasive cleaners or solvents.

8. Troubleshooting

If you encounter issues after lamp replacement, consider the following:

  • Lamp Not Lighting:
    • Ensure the lamp module is fully seated and its securing screws are tightened.
    • Verify the lamp cover is correctly installed and secured.
    • Check if the lamp timer was reset. Some projectors will not ignite a new lamp if the timer is not reset.
    • Confirm the projector is receiving power.
  • Dim Image / Poor Picture Quality:
    • Ensure the projector's display mode is set correctly (e.g., not in eco-mode if full brightness is desired).
    • Check for dust on the projector lens.
    • Verify the lamp timer was reset. If not, the projector might still be operating under the assumption of an old lamp.
  • Overheating Warning:
    • Check that the projector's air filters are clean and not obstructed.
    • Ensure adequate space around the projector for proper ventilation.

If problems persist, consult your projector's user manual or contact Dekain customer support.

9. Specifications

FeatureDetail
BrandDekain
Lamp TypePhilips UHP OEM Bulb (Metal Halide)
Wattage200 Watts
Special FeatureGenuine Projector Lamp with OEM Bulb Inside
Product DimensionsApproximately 4 x 5 x 4 inches
Compatible Part NumbersELPLP31, V13H010L31
UPC747976817149

10. Warranty and Support

Dekain provides the following warranty and support for this product:

  • Warranty: 1-year warranty for quality-related issues.
  • Return Policy: 30-day money-back guarantee.
  • Customer Service: 24/7 customer service with a response time within 12 hours.

For warranty claims, technical assistance, or any other inquiries, please contact Dekain customer support through your purchase platform or the official Dekain website.

© 2023 Dekain. All rights reserved.

Ask a question about this manual