1. Introduction
The VIVOSUN Air Quality Monitor, Model Ora-001, is designed to accurately detect and display various indoor air quality parameters. This device helps users monitor the levels of Formaldehyde (HCHO), Total Volatile Organic Compounds (TVOC), and Particulate Matter (PM1.0, PM2.5, PM10). Additionally, it measures ambient temperature and humidity, providing a comprehensive overview of your living environment's air quality.
2. Safety Information
- Do not attempt to disassemble or modify the device. Unauthorized modifications can lead to malfunction or damage.
- Keep the device away from water and high humidity environments to prevent electrical hazards.
- Use only the provided USB-C charging cable and a compatible 5V/1A power adapter for charging.
- Operate the device within the specified temperature range of 41-104°F (5-40°C) and humidity up to 90%.
- Avoid exposing the device to direct sunlight, extreme temperatures, or corrosive substances.
- Ensure the air intake and exhaust vents are not blocked during operation to maintain accurate readings.
3. Package Contents
Verify that all items are present in the package:
- VIVOSUN Air Quality Monitor (Model Ora-001)
- USB-C Charging Cable
- User Manual
4. Product Overview
The VIVOSUN Air Quality Monitor features a compact design with a clear LCD screen and intuitive controls.

The VIVOSUN Air Quality Monitor features a large color LCD screen for clear display of all measured parameters.
4.1 Device Components
- LCD Screen: Displays HCHO, TVOC, PM1.0, PM2.5, PM10, temperature, humidity, and air pollution level.
- Control Buttons: Navigation buttons (A, B, C, D, ESC, OK, Up/Down/Left/Right arrows) for menu interaction.
- Air Vents: Located on the sides and back for air intake and exhaust, facilitating sensor readings.
- USB-C Port: For charging the internal battery.

This image provides a detailed view of the monitor's LCD screen, illustrating how HCHO, TVOC, PM1.0, PM2.5, PM10 values, temperature, and humidity are displayed. It also shows the color-coded air pollution level indicator.

This image shows the front view of the VIVOSUN Air Quality Monitor, highlighting its compact size (approximately 6 inches tall and 2.7 inches wide) and the location of the air intake holes on the side.
5. Setup
5.1 Charging the Device
Before initial use, fully charge the air quality monitor.
- Connect the provided USB-C charging cable to the device's USB-C port.
- Plug the other end of the cable into a 5V/1A USB power adapter (not included) or a computer's USB port.
- The battery indicator on the screen will show charging status. A full charge typically takes approximately 3 hours.

This image shows the USB-C charging port located on the side of the VIVOSUN Air Quality Monitor, with a USB-C cable inserted. The device has a built-in 1200 mAh battery, providing 3-4 hours of operation on a full charge.
5.2 Powering On/Off
- To power on, press and hold the power button until the screen illuminates.
- To power off, press and hold the power button until the screen turns off.
5.3 Initial Calibration
For accurate readings, calibrate the device upon first use or after prolonged storage.
- Place the monitor in an area with fresh, clean air (e.g., outdoors away from pollution sources).
- Power on the device.
- Allow the device to operate for approximately 3 minutes to complete its initial calibration and register stable readings.
6. Operating Instructions
The monitor provides real-time data on various air quality parameters.
6.1 Understanding the Display
The LCD screen displays the following parameters:
- HCHO: Formaldehyde concentration (mg/m³).
- TVOC: Total Volatile Organic Compounds concentration (mg/m³).
- PM1.0, PM2.5, PM10: Particulate Matter concentrations (µg/m³).
- TEMP: Ambient Temperature (°C/°F).
- HUM: Relative Humidity (%).
- Air Pollution Level: A color-coded indicator (e.g., green for fresh, red for poor) provides a quick visual assessment.
6.2 Alarm System
The device features an alarm system to alert you to deteriorating air quality:
- When air quality is good, the indicator will typically be green.
- If air quality worsens and reaches predefined thresholds, the indicator will change (e.g., to red), and an audible alarm may sound to notify you.
6.3 Navigation and Settings
Use the control buttons to navigate through menus and adjust settings (e.g., unit conversion for temperature, alarm thresholds). Refer to the on-screen prompts for specific functions.

The monitor provides 24-hour real-time data monitoring, ensuring continuous air quality assessment.
6.4 Video Demonstration
This video demonstrates the VIVOSUN Air Quality Monitor in operation, showcasing its large LCD screen and high-sensitivity sensors for detecting various air pollutants.
7. Maintenance
7.1 Cleaning
- Wipe the exterior of the device with a soft, dry cloth.
- Do not use liquid cleaners, solvents, or abrasive materials, as these can damage the device or sensors.
- Ensure air vents are free from dust and debris. Do not insert objects into the vents.
7.2 Storage
- Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- If storing for an extended period, ensure the battery is partially charged (around 50%) to prolong its lifespan.
8. Troubleshooting
If you encounter issues with your VIVOSUN Air Quality Monitor, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | Battery is depleted. | Charge the device using the USB-C cable for at least 3 hours. |
| Inaccurate or fluctuating readings. | Device not properly calibrated; air vents blocked; environmental interference. | Perform initial calibration in fresh air. Ensure air vents are clear. Avoid strong air currents or chemical fumes near the device. |
| Audible alarm sounds frequently. | High levels of detected pollutants. | Ventilate the area. Identify and address sources of pollution. |
| Screen is blank or unresponsive. | Device frozen or battery issue. | Try restarting the device by holding the power button. If unresponsive, charge the device. |
9. Specifications
| Parameter | Detail |
|---|---|
| Brand | VIVOSUN |
| Model Number | Ora-001 |
| Detected Substances | Formaldehyde (HCHO), Total Volatile Organic Compounds (TVOC), Particulate Matter (PM1.0, PM2.5, PM10) |
| Additional Sensors | Temperature, Humidity |
| Item Weight | 0.3 kg |
| Alarm Type | Audible |
| Operating Humidity | Up to 90% |
| Battery Capacity | 1200 mAh |
| Charging Time | Approximately 3 hours |
| Battery Life (Operating) | 3-4 hours |
| Working Environment | 41-104°F (5-40°C) |
10. Warranty and Support
VIVOSUN products are manufactured to high-quality standards. For warranty information, technical support, or any questions regarding your VIVOSUN Air Quality Monitor, please contact VIVOSUN customer service through their official website or the retailer where the product was purchased. Please have your model number (Ora-001) and purchase details ready when contacting support.