1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your KETOTEK KT-D288+100A DC Battery Monitor Meter. This device is designed to accurately measure various electrical parameters of DC systems, including voltage, current, power, energy, capacity, impedance, internal resistance, and running time. Please read this manual thoroughly before use to ensure proper functionality and safety.
2. Product Features
- 9 Measurement Functions: Measures DC voltage (0-200V), discharge current (up to 100A), discharge power, discharge impedance, internal resistance, capacity, discharge energy, power consumption, and running time.
- HD LCD Display: Features a high-definition LCD screen with blue backlight for clear visibility from all angles, day or night.
- One-Button Control: Simplified operation for setting full and cut-off voltage, selecting current range, clearing data, and switching between normal/dormant modes.
- Screw-less Installation: Utilizes a plug-in terminal design for easy and convenient wire installation and removal without screws.
- High Precision: Equipped with a high-precision chip for efficient and stable operation, achieving 1% measurement accuracy.
- Wide Application: Suitable for use in automobiles, solar power systems, industrial assembly lines, and other DC power monitoring applications.
3. Safety Information
- Ensure all connections are secure and correct before applying power. Incorrect wiring can damage the device or connected equipment.
- Do not exceed the maximum voltage (200V DC) or current (100A DC) ratings of the device.
- Avoid exposing the device to moisture, extreme temperatures, or corrosive environments.
- Do not attempt to disassemble or modify the device. Refer all servicing to qualified personnel.
- Always disconnect power before making or changing any wiring connections.
4. Package Contents
Verify that all items are present in your package:
- KETOTEK KT-D288 DC Battery Monitor Meter
- 100A Shunt
- Connecting Wires

Image: The KETOTEK KT-D288 DC Battery Monitor Meter shown alongside its included 100A shunt and connecting wires.
5. Product Overview
The KETOTEK KT-D288 features a clear LCD display and a single control button for easy interaction.
5.1. Display Elements

Image: A close-up of the KETOTEK KT-D288 LCD display, highlighting Voltage, Current, Power, Energy, SOC, Capacity, External Resistance, Internal Resistance, and Running Time.
- Voltage (V): Displays the current DC voltage.
- Current (mA): Shows the current flow in milliamperes.
- Power (W): Indicates the instantaneous power consumption in watts.
- Energy (Wh): Accumulates the total energy consumed in watt-hours.
- Capacity (mAh): Displays the accumulated capacity in milliampere-hours.
- External Resistance (Ω): Shows the calculated external resistance.
- Internal Resistance (mΩ): Displays the calculated internal resistance.
- SOC (State of Charge): Battery icon indicating the approximate state of charge.
- Running Time: Tracks the elapsed time since the last reset.
5.2. Control Button

Image: A close-up view of the single control button located on the side of the KETOTEK KT-D288 meter.
The single button on the side of the meter is used for various settings and data management.
6. Setup
6.1. Wiring Diagram
Follow the wiring diagram carefully to connect the meter and shunt to your DC power system. Ensure all connections are correct and secure.

Image: Detailed wiring diagram showing connections for the KETOTEK KT-D288 meter, 100A shunt, battery (DC 0-200V), and load. An external power supply (3.3-12V) is indicated for use when the battery voltage is below 8V.
- Connect the Shunt in series with the negative terminal of your battery and the negative terminal of your load.
- Connect the meter's main power input (red and black wires) to the positive and negative terminals of the battery, respectively.
- If the battery voltage is below 8V, an external power supply (3.3-12V DC) is required for the meter. Connect it to the designated external power supply terminals.
- Ensure the current range is correctly set (0-20A or 0-100A, 100A is default).
6.2. Screw-less Terminal Installation
The meter features push-on terminals for easy wire installation.

Image: A close-up of the KETOTEK KT-D288's push-on terminals, demonstrating how to insert a wire by pressing the terminal button.
- To insert a wire, gently press the corresponding terminal button.
- Insert the stripped end of the wire into the opening.
- Release the button to secure the wire.
- To remove a wire, press the button again and pull the wire out.
7. Operating Instructions
7.1. Powering On
Once correctly wired, the meter will power on automatically when DC voltage is applied. The LCD display will illuminate, showing the current measurement parameters.
7.2. Understanding the Display
The display provides real-time readings for all 9 measurement functions. The blue backlight ensures readability in various lighting conditions.

Image: Three views of the KETOTEK KT-D288 LCD display from different angles, demonstrating its wide viewing angle and clear readability with blue backlight.
7.3. One-Button Settings
The single button on the side of the meter allows for quick adjustments and data management:
- Set Full and Cut-off Voltage: Press and hold the button to enter voltage setting mode. Use short presses to adjust values.
- Current Range Setting: Press and hold to cycle through available current ranges (e.g., 0-20A, 0-100A).
- Clear Data: A specific press sequence (refer to on-screen prompts or detailed product documentation if available) will clear accumulated data such as capacity, energy, and running time.
- Normal/Dormant Mode: Short press to toggle between normal operation and a low-power dormant mode.
8. Maintenance
- Cleaning: Use a soft, dry cloth to clean the meter's surface. Do not use abrasive cleaners or solvents.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures when not in use.
- Inspection: Periodically check all wiring connections for tightness and signs of wear or corrosion.
9. Troubleshooting
- No Display:
- Check power connections to the meter.
- If battery voltage is below 8V, ensure the external power supply is connected and functioning.
- Incorrect Readings:
- Verify all wiring connections, especially the shunt, are correct according to the diagram.
- Ensure the current range setting matches your application.
- Check for loose connections or damaged wires.
- Button Not Responding:
- Ensure the device is powered on.
- Try a gentle reset by disconnecting and reconnecting power.
10. Specifications

Image: Diagram showing the physical dimensions of the KETOTEK KT-D288 meter: 90mm (length), 50mm (width), 24mm (height), and 84mm (panel cutout length), 44mm (panel cutout width).
| Parameter | Value |
|---|---|
| Model Number | KT-D288+100A |
| Voltage Measurement Range | 0-200V DC |
| Current Measurement Range | 0-100A DC (with 100A Shunt) |
| Measurement Accuracy | 1% |
| Display Type | LCD with Blue Backlight |
| Dimensions (L x W x H) | 90 x 50 x 24 mm |
| Weight | 220 Grams |
| Power Source | Cable Electrical (or External 3.3-12V DC if battery < 8V) |
| Compliance | CE, FCC, RoHS, UL |
| Operating Temperature | Not specified (typical range for electronics) |
11. Warranty and Support