Racold CDR DLX 10V 2KW WH

Racold CDR DLX 10L Water Heater User Manual

Model: CDR DLX 10V 2KW WH

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Racold CDR DLX 10L Water Heater. Please read these instructions carefully before using the appliance and retain them for future reference. Proper adherence to these guidelines will ensure optimal performance and longevity of your water heater.

2. Safety Information

Your safety and the safety of others are paramount. Please observe all safety warnings and precautions outlined in this manual. Failure to do so may result in injury or damage to the appliance.

  • Ensure the water heater is installed by a qualified technician in accordance with local regulations and this manual.
  • Do not operate the water heater if it is damaged or malfunctioning. Contact authorized service personnel immediately.
  • Always disconnect the power supply before performing any maintenance or cleaning.
  • Do not block the pressure relief valve. Regular checks are necessary to ensure it is not obstructed.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.

3. Product Overview

The Racold CDR DLX 10L Water Heater is designed for efficient and reliable hot water supply. It features advanced technologies for durability and safety.

Key Features:

  • Titanium Plus Technology: Titanium enamel coating in the tank and heating element prevents corrosion, ensuring longevity even with tough water conditions.
  • Rust Proof Body: The robust body design acts against corrosion, extending product life and maintaining aesthetics.
  • Safety Plus: Enhanced protection with 3 layers of safety, including a thermostat, cutout, and safety valve, for a worry-free experience.
  • HPR Technology: The sturdy tank is built to withstand high pressure, making it suitable for high-rise buildings.
  • Magnesium Anode: A larger anode prevents corrosion of the inner tank, extending its operational life.
  • 5-Star BEE Certified: Energy-efficient design to help reduce power consumption.

Product Components:

The package includes:

  • 1 x Racold CDR DLX 10L Water Heater
  • 1 x Instruction Booklet
  • 1 x Safety Valve
  • 2 x Dielectric Joints
Racold CDR DLX 10L Water Heater with key features highlighted

Image 3.1: Front view of the Racold CDR DLX 10L Water Heater, illustrating its main features like Titanium Plus Technology, Rust Proof Body, Safety Plus, HPR Technology, and Magnesium Anode.

Racold Water Heater with Titanium Plus Technology detail

Image 3.2: Detail showcasing the Titanium Plus Technology, which involves a titanium enamel coating for corrosion prevention in the tank and heating element.

Racold Water Heater with Rust Proof Body detail

Image 3.3: Detail highlighting the Rust Proof Body feature, designed to protect against corrosion and ensure a longer product lifespan.

Racold Water Heater with Safety Plus detail

Image 3.4: Detail explaining Safety Plus, which incorporates a 3-layer safety system with a thermostat, cutout, and safety valve for user protection.

Racold Water Heater with HPR Technology detail

Image 3.5: Detail illustrating HPR Technology, indicating the water heater's ability to withstand high pressure, making it suitable for multi-story buildings.

Racold Water Heater with Magnesium Anode detail

Image 3.6: Detail explaining the Magnesium Anode, a component that prevents corrosion of the inner tank and extends the water heater's life.

4. Installation

Installation of the Racold CDR DLX 10L Water Heater must be performed by a certified professional to ensure safety and proper functioning. Refer to the included instruction booklet for detailed diagrams and step-by-step procedures.

Pre-Installation Checks:

  • Verify that the wall can support the weight of the water heater when full (approximately 17.34 kg for 10L model).
  • Ensure adequate space for maintenance and ventilation around the unit.
  • Confirm that the electrical supply matches the appliance's requirements (230 Volts).

Mounting:

The water heater is designed for wall mounting. Use appropriate fasteners and follow the mounting template provided in the full manual.

Side view of Racold CDR DLX 10L Water Heater

Image 4.1: Side view of the water heater, useful for understanding mounting points and connections.

Back view of Racold CDR DLX 10L Water Heater

Image 4.2: Back view of the water heater, showing the mounting bracket and inlet/outlet connections.

Plumbing Connections:

  1. Connect the cold water inlet to the designated port (usually marked blue).
  2. Connect the hot water outlet to the designated port (usually marked red).
  3. Install the provided safety valve on the cold water inlet line.
  4. Ensure all connections are watertight using the provided dielectric joints and appropriate sealing materials.

Electrical Connections:

  1. Connect the water heater to a dedicated electrical circuit with proper grounding.
  2. Ensure the circuit is protected by a suitable circuit breaker or fuse.
  3. All electrical wiring must comply with local electrical codes.

5. Operating Instructions

Follow these steps for safe and effective operation of your Racold water heater.

Initial Startup:

  1. After installation, open a hot water tap in your home to allow air to escape from the tank.
  2. Slowly open the cold water inlet valve to fill the water heater tank.
  3. Once water flows steadily from the hot water tap, close the tap.
  4. Connect the power supply to the water heater.

Temperature Adjustment:

The water heater is equipped with a thermostat for temperature control. Refer to the control panel on your unit to adjust the desired water temperature. Avoid setting the temperature too high to prevent scalding and conserve energy.

Normal Operation:

The water heater will automatically heat water to the set temperature and maintain it. The indicator light will illuminate when the heating element is active and turn off once the desired temperature is reached.

6. Maintenance

Regular maintenance ensures the efficiency and extends the lifespan of your water heater. Always disconnect power before performing maintenance.

Annual Maintenance:

  • Drain and Flush Tank: Annually drain and flush the tank to remove sediment buildup. This helps maintain heating efficiency and prevents corrosion.
  • Inspect Pressure Relief Valve: Manually operate the pressure relief valve once a year to ensure it is not blocked and functions correctly. Follow manufacturer guidelines for this procedure.
  • Check Anode Rod: The magnesium anode rod should be inspected and replaced if significantly corroded, typically every 1-3 years depending on water quality. This is crucial for preventing inner tank corrosion.
  • Inspect Connections: Check all water and electrical connections for leaks or signs of wear.

Cleaning:

Clean the exterior of the water heater with a soft, damp cloth. Do not use abrasive cleaners or solvents.

7. Troubleshooting

This section addresses common issues you might encounter with your water heater. For problems not listed here, or if solutions do not resolve the issue, contact Racold customer support.

ProblemPossible CauseSolution
No hot waterNo power supply
Thermostat set too low
Heating element failure
Check circuit breaker/fuse
Adjust thermostat setting
Contact service technician
Insufficient hot waterTank too small for demand
Thermostat set too low
Sediment buildup
Consider a larger capacity unit
Increase thermostat setting
Drain and flush tank
Water too hotThermostat set too highDecrease thermostat setting
Leaking waterLoose connections
Pressure relief valve discharge
Tank leak
Tighten connections
Check water pressure, ensure proper drainage
Contact service technician (tank leaks usually require replacement)
Unusual noises (e.g., popping, rumbling)Sediment buildup in tankDrain and flush tank thoroughly

8. Specifications

FeatureDetail
BrandRacold
Model NumberCDR DLX 10V 2KW WH
Capacity10 Liters
Power SourceCorded Electric
Voltage230 Volts
Power Consumption2000 Watts (2KW)
Energy Efficiency5-star BEE certified
Product Dimensions (W x H)32W x 45H Centimeters
Item Weight7.34 Kilograms
Mount TypeWall
Tank MaterialTitanium Enameled Steel
Special FeaturesRustproof, Titanium Plus Technology, Safety Plus, HPR Technology, Magnesium Anode
ColorWhite

9. Warranty and Support

Racold provides comprehensive warranty coverage for your water heater.

Warranty Details:

  • Inner Tank: 5 Years
  • Heating Element: 2 Years
  • On Product: 2 Years

Please retain your purchase receipt for warranty claims. The warranty covers manufacturing defects under normal use conditions.

Racold Water Heater Warranty and Free Installation details

Image 9.1: Visual representation of the warranty periods for the tank, heating element, and overall product. Also mentions free installation and pipes.

Customer Support:

For installation assistance, service requests, or any queries regarding your Racold water heater, please contact Racold customer support. Refer to the contact information provided in your product booklet or visit the official Racold website.

© 2026 Racold. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.