Okin JLDQ.10.435.250I

Okin JLDQ.10.435.250I Recliner Bed Actuator Motor Replacement Manual

Model: JLDQ.10.435.250I

1. Introduction

This manual provides essential information for the safe and effective installation, operation, and maintenance of your Okin JLDQ.10.435.250I recliner bed actuator motor. Please read these instructions thoroughly before proceeding with installation or use to ensure proper function and longevity of the product.

2. Product Overview

The Okin JLDQ.10.435.250I is a refined linear actuator motor designed for recliner beds and power lift chairs. It serves as a direct replacement for specific Okin JLDQ series motors. The actuator motor set includes one motor unit and two connectors: a 5-pin round plug for the switch hand control and a 2-pin square plug with a clip for the power supply.

Okin JLDQ.10.435.250I Recliner Motor

Image 2.1: The Okin JLDQ.10.435.250I recliner bed actuator motor.

Okin JLDQ.10.435.250I Motor Connectors

Image 2.2: Close-up of the 2-pin power supply plug and 5-pin recliner switch plug.

3. Specifications

FeatureDetail
ModelJLDQ.10.435.250I
AppearanceBlack (PA), Silver White (Aluminum)
Stroke250 mm
Minimum Dimensions (Shrink)435 mm
Maximum Dimensions (Extended)685 mm
Load (Push Force)1000 N
Load (Pull Force)1000 N
Operation FrequencyOn 1 min / Off 8 min
Power Input24V === 50W (as per label)
Serial Number ExampleQ21053376 00006
Okin JLDQ.10.435.250I Motor Label with Specifications

Image 3.1: Product label showing model number JLDQ.10.435.250I and technical data.

4. Compatibility

This Okin JLDQ.10.435.250I motor is designed as a replacement for the original Okin JLDQ motor, model JLDQ.10.435.250I. It can also replace the following models, though minor differences may exist that do not affect general use:

  • JLDQ.19B.435.250D02
  • JLDQ.19B.435.250D03
  • JLDQ.19B.435.250D04
  • JLDQ.10.435.250
  • JLDQ.3.435.250
  • 1.28.000.110.30 series

Important: Always verify your existing motor's brand, model, minimum install dimension, stroke, and plug types to ensure compatibility with the replacement unit. Different actuators may not be compatible with all recliner frames.

5. Safety Information

Please observe the following safety precautions:

  • Ensure the power supply is disconnected before attempting any installation, maintenance, or troubleshooting.
  • This motor is designed for indoor use only.
  • Do not operate the motor if any part is damaged or if the cables are frayed.
  • Keep hands and loose clothing clear of moving parts during operation.
  • Connection is only to class 2 DC circuit.
  • If you are unsure about any step, consult a qualified technician.

6. Installation

The installation process is generally straightforward. Follow these steps:

  1. Disconnect Power: Unplug the recliner or bed from the main power outlet.
  2. Access Motor: Carefully position the recliner to access the existing motor. This may involve tilting the chair or removing a fabric cover.
  3. Disconnect Old Motor:
    • Disconnect the 5-pin round plug from the hand control.
    • Disconnect the 2-pin square plug from the power supply.
    • Unbolt or unclip the old motor from the recliner frame.
  4. Remove Old Motor: Carefully remove the old actuator motor from the recliner mechanism.
  5. Install New Motor:
    • Position the new Okin JLDQ.10.435.250I motor in the same location as the old one.
    • Securely bolt or clip the new motor to the recliner frame.
  6. Connect New Motor:
    • Connect the 5-pin round plug to the hand control.
    • Connect the 2-pin square plug with the clip to the power supply. Ensure a secure connection.
  7. Test Functionality: Reconnect the recliner to the power outlet and test the motor's operation using the hand control. Ensure smooth extension and retraction.
Okin JLDQ.10.435.250I Motor Side View

Image 6.1: Side view of the motor, showing mounting points and overall structure.

Okin JLDQ.10.435.250I Motor Angled View

Image 6.2: Angled view of the motor, illustrating its compact design for installation.

7. Operation

Once installed and connected, operate the recliner motor using the hand control unit. Press the appropriate buttons on the hand control to extend or retract the recliner mechanism. The motor is designed for intermittent use with an operation frequency of "On 1 min / Off 8 min" to prevent overheating and ensure longevity.

Product Features and Recliner Application

Image 7.1: Visual representation of the motor's features and its application in a recliner chair.

8. Maintenance

The Okin JLDQ.10.435.250I motor requires minimal maintenance:

  • Cleaning: Keep the motor free from dust and debris. Wipe with a dry cloth. Do not use liquid cleaners directly on the motor.
  • Inspection: Periodically inspect the motor and all connections for any signs of wear, damage, or loose fittings.
  • Lubrication: The motor is factory-lubricated and generally does not require additional lubrication.

9. Troubleshooting

If your recliner motor is not functioning correctly, consider the following:

  • No Power:
    • Ensure the recliner is securely plugged into a working power outlet.
    • Check the power supply unit for any indicator lights or signs of damage.
    • Verify the 2-pin square plug connection to the power supply is firm.
  • Motor Not Responding:
    • Check the 5-pin round plug connection to the hand control.
    • Inspect the hand control for damage or stuck buttons.
    • Ensure the motor is not jammed by any obstructions in the recliner mechanism.
  • Motor Overheating:
    • Adhere to the "On 1 min / Off 8 min" operation frequency. Excessive continuous use can cause overheating.
    • Ensure adequate ventilation around the motor.
  • Unusual Noises:
    • Disconnect power and inspect the motor and recliner mechanism for any loose parts or foreign objects.

If troubleshooting steps do not resolve the issue, contact customer support.

10. Warranty and Support

For warranty information, technical support, or to inquire about replacement parts, please refer to the official Okin brand store or contact your retailer. Keep your purchase receipt for warranty claims.

Visit the official Okin Store: Okin Store on Amazon

Related Documents - JLDQ.10.435.250I

Preview Assembly Instructions for YB2213 Power Lift Recliner Chair
Step-by-step assembly guide for the YB2213 power lift recliner chair, including package contents, connection steps, and wiring instructions for power and remotes. Features heat and massage functions.
Preview Okin Systems Troubleshooting Guide: Lift Chair Repair and Maintenance
Comprehensive troubleshooting guide for Okin Systems used in lift chairs. Learn to diagnose and fix common issues with hand controls, transformers, motors, and spindle nuts. Includes installation tips.
Preview OKIN HSW306 5-Pin to 7-Pin Remote Controller Replacement Guide
Step-by-step instructions for replacing an OKIN HSW306 5-pin recliner remote controller with a 7-pin model, including wiring bypass, installation steps, and recommended accessories.
Preview OKIN RF.31.24.01 Remote Control System User Manual
Comprehensive user manual for the OKIN RF.31.24.01 22-key remote control system, detailing button functions, position setting procedures, and system components for adjustable beds.
Preview OKIN CB3433A Control Box Function Instruction and Operation Guide
This document provides a detailed function instruction for the OKIN CB3433A control box, a component for adjustable furniture systems manufactured by OKIN, a Phoenix Mecano Company. It outlines the electrical configuration, describes the control box interface, and explains the operation of various actuators (head, foot, lumbar), massage motors, and underbed RGB lighting. The guide also covers LED indicators, pairing procedures, connectivity options (SYNC, USB, UART), power requirements, and includes FCC and ISED RSS regulatory warnings. Written by Jarek from the R&D Division.
Preview OKIN CB.2542 Control Box: Product Function Instruction
Detailed instructions and functional overview for the OKIN CB.2542 Control Box, covering actuator control, massage functions, LED indicators, and pairing procedures. Includes FCC and ISED compliance statements.