1. Introduction

This manual provides essential information for the safe and efficient operation of your Temank Solar Inverter 5000W. Please read this manual thoroughly before installation and use, and keep it for future reference.

Temank Solar Inverter 5000W

Figure 1: Temank Solar Inverter 5000W, a pure sine wave power inverter with built-in MPPT controller and AC charger.

2. Key Features

  • 5000W Pure Sine Wave Inverter: Provides clean and stable power for various appliances.
  • 80A MPPT Charge Controller: Maximizes solar power harvesting efficiency.
  • 40A AC Charger: Enables charging from utility grid or generator.
  • Wide PV Input Range: Supports 120-500Vdc, with a maximum PV input of 5500W.
  • Battery Compatibility: Compatible with 48V Lead-Acid (sealed, AGM, Gel, Flooded) and Lithium batteries.
  • Multiple Charging Modes: PV priority, Utility Priority, Hybrid Charging, and Only Solar Charging.
  • LCD Display: Dynamic display of system data and operating status with 3 LED indicators.
  • Intelligent Cooling: Variable speed fan for efficient heat dissipation.
Solar Inverter Features

Figure 2: Overview of the 5000W Off-Grid Solar Inverter's key specifications and capabilities.

Inverter Charging Modes

Figure 3: Illustration of the four charging modes and three load output working modes available on the inverter.

3. Setup and Installation

3.1 Safety Precautions

  • Ensure all power sources are disconnected before installation.
  • Installation should be performed by qualified personnel.
  • Wear appropriate personal protective equipment (PPE).
  • Ensure proper grounding of the inverter.

3.2 Wiring Diagram

Refer to the following diagram for correct wiring connections. Ensure all connections are secure and properly insulated.

Inverter Wiring Diagram

Figure 4: Detailed wiring diagram showing connections for solar panels, battery, AC input (utility/generator), and AC output.

Note: The diagram is for reference only. Actual wiring methods may vary based on your specific setup and local regulations. Always connect the PE protective conductor (ground wire) first.

3.3 Installation Video Guide

For a visual guide on the installation process, please refer to the official installation video:

Video 1: Official inverter installation video by Y-SOLAR, demonstrating the physical setup and initial connections.

Video 2: Comprehensive tutorial for beginners on inverter setup, covering various aspects of installation and configuration.

Video 3: POW-LVM3K-24V-H Installation and Wiring Guide, providing detailed steps for wiring the inverter.

4. Operating Instructions

4.1 LCD Display and Buttons

The inverter features an LCD display and three LED indicators for dynamic display of system data and operating status. Use the buttons below the display to navigate and make settings.

SmartESS App Monitoring

Figure 5: The inverter's LCD display and control buttons, with an optional Wi-Fi/GPRS module for remote monitoring via the SmartESS App.

For detailed parameter settings, refer to the "Setting Parameter Steps" video:

Video 4: Guide on setting various parameters of the inverter using the control buttons.

5. Maintenance

  • Regularly inspect all wiring connections for tightness and corrosion.
  • Keep the inverter clean and free from dust and debris to ensure proper ventilation.
  • Ensure the intelligent variable speed fan is operating correctly.
  • Monitor battery health and voltage levels as per battery manufacturer guidelines.

6. Troubleshooting

If the inverter displays a fault code or exhibits abnormal behavior, refer to the troubleshooting guide below. For common fault codes and their meanings, consult the official troubleshooting video:

Video 5: Troubleshooting Fault Codes, explaining how to identify and address common issues indicated by the inverter's display.

Common Issues:

  • No Power Output: Check battery connections, solar panel input, and AC input. Ensure the inverter is turned on.
  • Overload Alarm: Reduce the connected load. The inverter supports up to 5000W.
  • Battery Not Charging: Verify solar panel voltage and current. Check AC input if charging from grid/generator. Ensure battery type settings are correct.
  • High Temperature Alarm: Ensure adequate ventilation around the inverter. Clean any dust from the fan and vents.

7. Technical Specifications

ParameterValue
Model NamePOW-LVM
Wattage5000 watts
Power SourceSolar Powered
Battery Capacity (Recommended)200 Amp Hours (48V system)
Max. PV Input Power5500W
Max. PV Input Voltage500Vdc
Max. PV Input Current22A
Max. Charge Current (MPPT)80A
Max. AC Charge Current40A
AC Input Voltage Range90-140Vac
AC Output Voltage100/105/110Vac ±5%
Item Weight26.4 pounds
ManufacturerTemank

8. Warranty Information

The Temank Solar Inverter 5000W comes with the following warranty:

  • Free Replacement: Within 30 days of purchase.
  • Free Repair and Parts Replacement: Within 1 year of purchase. Shipping costs incurred for repairs/replacements need to be borne by the customer.

For warranty claims, please contact Temank customer support.

9. Support and Resources

For additional support and detailed documentation, please refer to the following resources:

You can also visit the official Temank Store on Amazon for more product information and assistance.

© 2024 Temank. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.