1. Introduction
The OWON SP6103 is a high-performance single-channel linear DC power supply designed for various applications requiring stable and precise power. This unit provides a maximum output of 60V and 10A, with a total power output of 300W. It features a 3.7-inch TFT LCD for clear display of parameters, low ripple and noise, and essential protection functions such as over-voltage (OVP) and over-current (OCP) protection. The SP6103 supports both Constant Voltage (CV) and Constant Current (CC) output modes and includes an RS232 port for remote control via SCPI commands.
2. Safety Instructions
To ensure safe operation and prolong the lifespan of your OWON SP6103 power supply, please read and adhere to the following safety guidelines:
- Power Source: Connect the unit only to a power source that matches the voltage and frequency specified on the product label. Ensure the power cord is properly grounded.
- Ventilation: Do not block the ventilation openings on the sides and rear of the unit. Adequate airflow is essential to prevent overheating.
- Environment: Operate the power supply in a dry, well-ventilated indoor environment. Avoid exposure to moisture, dust, direct sunlight, or extreme temperatures.
- Load Connection: Always connect the load to the output terminals before turning on the output. Ensure correct polarity.
- Output Terminals: Do not touch the output terminals when the output is active. High voltage and current can cause electric shock.
- Maintenance: Refer all servicing to qualified personnel. Do not attempt to open or repair the unit yourself.
- Cleaning: Disconnect the power cord before cleaning. Use a soft, dry cloth. Do not use liquid cleaners or aerosols.
3. Product Overview
3.1 Front Panel
The front panel provides all controls and the display for operating the power supply.

Figure 3.1: Front Panel Layout
- Display: 3.7-inch TFT LCD showing output voltage, current, power, OVP/OCP settings, and status indicators.
- Power Switch: Main power toggle for the unit.
- System Button: Accesses system settings and configurations.
- Memory Button: Used to save and recall output settings.
- Keylock Button: Locks the front panel controls to prevent accidental changes.
- Navigation Buttons (Up, Down, Left, Right, OK): Used for menu navigation and parameter adjustment.
- Knob: Fine adjustment of voltage and current parameters.
- On/Off Button: Toggles the output power to the terminals.
- Output Terminals: Red (+) for positive, Green (Ground) for chassis ground, Black (-) for negative output.
3.2 Side View and Ventilation
The side panels feature ventilation grilles to ensure proper cooling of the internal components.
Figure 3.2: Side Ventilation
4. Setup
Follow these steps to set up your OWON SP6103 power supply:
- Unpacking: Carefully remove the power supply from its packaging. Inspect the unit for any signs of damage during transit.
- Placement: Place the unit on a stable, level surface, ensuring adequate space around the ventilation openings for proper airflow.
- Power Connection: Connect the provided AC power cord to the power input on the rear panel of the SP6103, then plug the other end into a grounded AC outlet.
- Initial Power On: Flip the main power switch on the front panel to the 'ON' position. The display should illuminate.
- Load Connection: Before activating the output, connect your load to the output terminals. Connect the positive (+) terminal of your load to the red (+) terminal of the power supply, and the negative (-) terminal of your load to the black (-) terminal of the power supply. If grounding is required, connect to the green (Ground) terminal.
5. Operating Instructions
5.1 Setting Voltage and Current
To set the desired output voltage and current:
- Ensure the output is OFF (the 'On/Off' button LED is off).
- Use the navigation buttons (Left/Right) to select the parameter you wish to adjust (Voltage or Current). The selected parameter will be highlighted.
- Rotate the Knob to adjust the value. Press the OK button to confirm the value or move to the next digit for fine adjustment.
- Repeat for both voltage and current limits.
5.2 Activating Output
After setting the desired voltage and current limits, press the On/Off button to activate the output. The LED on the button will illuminate, and the actual output voltage and current will be displayed.
5.3 Constant Voltage (CV) / Constant Current (CC) Mode
The SP6103 automatically operates in either Constant Voltage (CV) or Constant Current (CC) mode depending on the load. If the load resistance is high, the unit will operate in CV mode, maintaining the set voltage. If the load resistance is low, causing the current to reach the set limit, the unit will switch to CC mode, maintaining the set current and reducing the output voltage.
5.4 Over-Voltage Protection (OVP) and Over-Current Protection (OCP)
The SP6103 includes OVP and OCP features to protect the connected load and the power supply itself.
- Setting OVP/OCP: Access the OVP/OCP settings through the System menu or dedicated display area. Use the navigation buttons and knob to set the desired protection thresholds.
- Triggering Protection: If the output voltage or current exceeds the set OVP or OCP limits, the output will automatically shut down, and an indicator will appear on the display.
- Resetting Protection: To clear a protection trigger, turn off the output, resolve the condition that caused the trigger, and then turn the output back on.
5.5 Memory Functions
The Memory button allows you to save and recall frequently used voltage and current settings. Consult the on-screen prompts for saving to and recalling from memory slots.
5.6 Keylock Function
Press the Keylock button to disable the front panel controls, preventing accidental changes to the output settings during operation. Press it again to unlock.
5.7 RS232 Communication
The SP6103 features an RS232 port for remote control and data logging. It supports Standard Commands for Programmable Instruments (SCPI). Refer to the detailed programming manual (if available from the manufacturer) for specific SCPI commands and communication protocols.
6. Maintenance
The OWON SP6103 requires minimal maintenance to ensure optimal performance:
- Cleaning: Regularly clean the exterior of the unit with a soft, dry, lint-free cloth. Do not use abrasive cleaners or solvents. Ensure the unit is powered off and unplugged before cleaning.
- Ventilation: Periodically check that the ventilation openings are free from dust and debris. Use compressed air to gently clear any blockages if necessary.
- Storage: When not in use for extended periods, store the power supply in a cool, dry place, away from direct sunlight and extreme temperatures.
7. Troubleshooting
If you encounter issues with your OWON SP6103, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not power on | No AC power; Power cord loose; Main power switch off | Check AC outlet; Ensure power cord is securely connected; Turn main power switch ON |
| No output voltage/current | Output is OFF; OVP/OCP triggered; Load disconnected or faulty | Press 'On/Off' button; Check OVP/OCP settings and reset if triggered; Verify load connection and functionality |
| Output voltage/current unstable | Poor load connection; Overheating | Ensure secure load connections; Check ventilation, reduce load if necessary |
| Display shows error message | Internal fault; Protection triggered | Note error code and consult manufacturer support; Reset protection as described in section 5.4 |
8. Specifications
The following table outlines the key technical specifications for the OWON SP6103 DC Power Supply:
Figure 8.1: OWON SP Series Specifications Overview
| Parameter | Specification (SP6103) |
|---|---|
| Model Number | SP6103 |
| Channel | Single Channel |
| Output Voltage | 0-60V |
| Output Current | 0-10A |
| Output Power | 300W |
| Voltage Resolution | 10mV |
| Current Resolution | 10mA |
| Display | 3.7 inch TFT LCD |
| Ripple/Noise (Vp-p) | ≤30mVp-p |
| Ripple/Noise (rms) | ≤3mVrms |
| Protection | Over-Voltage Protection (OVP), Over-Current Protection (OCP) |
| Interface | RS232 (SCPI support) |
| Dimensions (W×H×D) | 117mm × 194mm × 295mm |
| Weight | Approx. 2.3kg (5.07 lbs) |
| Operating Temperature | 0-40°C |
| Input Voltage | 220-240V AC |
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your authorized OWON dealer or the manufacturer directly. Keep your purchase receipt as proof of purchase for warranty claims. Specific warranty terms and conditions may vary by region and retailer.