VOLTCRAFT VC-11015505

VOLTCRAFT DL-250V Voltage Data Logger User Manual

Model: VC-11015505

1. Introduction

This manual provides essential information for the safe and efficient operation of your VOLTCRAFT DL-250V Voltage Data Logger. Please read this manual thoroughly before using the device and keep it for future reference.

The VOLTCRAFT DL-250V is a compact and powerful portable data logger with an LCD display and integrated lithium battery. It is designed to monitor and record measured voltage data. The data logging capacity is designed to store a large number of measurement data points based on adjustable criteria. The logger can be individually configured via a web browser. Once data recording is complete and the logger is connected to a USB interface, a PDF file and an additional spreadsheet file are automatically generated. This record contains general device information, data logger settings, alarm status, and a graph showing measured values over the recorded time.

2. Product Overview

2.1 Key Features

  • Measurement range: 0 – 30 V/DC
  • Portable data logger with LCD display
  • 31320 readings storable
  • Adjustable measurement interval: from 10 seconds to 24 hours
  • Automatic PDF report generation

2.2 Device Components

VOLTCRAFT DL-250V Data Logger with red and black alligator clips connected.

Figure 1: VOLTCRAFT DL-250V Data Logger with connected voltage probes (red and black alligator clips). The LCD display shows a voltage reading.

VOLTCRAFT DL-250V Data Logger standing upright, showing the display and connected probes.

Figure 2: Upright view of the DL-250V, highlighting the LCD screen and the input terminals for the voltage probes.

VOLTCRAFT DL-250V Data Logger with the USB protective cap removed, revealing the USB-A connector.

Figure 3: The DL-250V with its USB protective cap removed, showing the integrated USB-A connector for PC connection and data transfer.

VOLTCRAFT DL-250V Data Logger from an angled view, showing the USB connector and probes.

Figure 4: Angled view of the DL-250V, illustrating the compact design with the USB connector and probe inputs visible.

3. Setup

3.1 Initial Battery Charge

The DL-250V has an integrated lithium battery. For optimal performance, ensure the device is sufficiently charged before first use. Connect the data logger to a standard USB port on a computer or a USB power adapter. The battery indicator on the LCD will show charging status.

3.2 Software Configuration (Web Browser)

The DL-250V does not require dedicated software installation. Configuration is performed via a web browser:

  1. Remove the protective cap to expose the USB-A connector (refer to Figure 3).
  2. Plug the data logger directly into a USB port on your computer.
  3. The device will be recognized as a removable storage device. Navigate to the device's root directory.
  4. Locate and open the HTML configuration file (e.g., "config.html" or similar) in your web browser.
  5. Follow the on-screen instructions in the web interface to set measurement parameters such as:
    • Measurement interval (e.g., 10 seconds to 24 hours)
    • Start/Stop conditions
    • Alarm thresholds (if applicable)
  6. Save the configuration to the device. Safely eject the device from your computer after configuration.

Note: Ensure your web browser is up-to-date for optimal compatibility with the configuration interface.

4. Operating Instructions

4.1 Connecting Probes

Connect the red alligator clip to the positive (+) terminal and the black alligator clip to the negative (-) terminal of the voltage source you wish to measure. Ensure a secure connection to prevent inaccurate readings.

4.2 Starting Data Logging

Once configured, the device will begin logging data according to the set parameters. The LCD display will show current readings and logging status. Refer to the display icons for information on active logging, battery status, and alarm indicators.

4.3 Stopping Data Logging

Logging will automatically stop based on the configured stop conditions (e.g., reaching maximum readings, specific time). You can also manually stop logging if the device supports it (refer to the web configuration interface for manual stop options).

5. Data Logging and Export

After data logging is complete, you can retrieve the recorded data:

  1. Connect the DL-250V to a USB port on your computer.
  2. The device will appear as a removable drive.
  3. Automatically, a PDF report and an additional spreadsheet file (e.g., CSV or Excel) will be generated in the device's root directory.
  4. Open the PDF report for a summary of the logging session, including general device information, settings, alarm status, and a graphical representation of the measured values over time.
  5. Open the spreadsheet file for raw data, which can be used for further analysis in spreadsheet software.
  6. Copy the generated files to your computer for permanent storage.
  7. Safely eject the device from your computer.

6. Maintenance

6.1 Cleaning

Clean the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the USB port is free of dust and debris.

6.2 Storage

Store the data logger in a cool, dry place away from direct sunlight and extreme temperatures. Ensure the USB protective cap is in place when not in use to protect the connector.

6.3 Battery Care

The integrated lithium battery is not user-replaceable. To prolong battery life, avoid fully discharging the device frequently and store it with a partial charge if not used for extended periods.

7. Troubleshooting

ProblemPossible CauseSolution
Device not recognized by PC.Loose USB connection, faulty USB port, driver issue.Try a different USB port. Ensure the USB connector is fully inserted. Restart your computer.
No data recorded.Incorrect configuration, battery low, probes not connected correctly.Check configuration settings via the web interface. Ensure battery is charged. Verify probe connections.
PDF/Spreadsheet not generated.Logging not completed, device not safely ejected previously.Ensure logging session has finished. Reconnect the device and wait for automatic generation.
Inaccurate readings.Poor probe connection, interference, device malfunction.Check probe connections. Ensure no strong electromagnetic interference. If problem persists, contact support.

8. Specifications

BrandVOLTCRAFT
Model NumberVC-11015505
Measurement Range0 - 30 V/DC
Data Storage Capacity31320 readings
Measurement IntervalAdjustable from 10 seconds to 24 hours
Power SourceIntegrated Lithium Battery
Dimensions (L x W x H)9.3 x 3.7 x 1.9 cm
Weight59 grams
ColorBlack

9. Warranty and Support

For warranty information and technical support, please refer to the official VOLTCRAFT website or contact your local distributor. Keep your purchase receipt as proof of purchase for warranty claims.

Manufacturer: VOLTCRAFT

© 2025 VOLTCRAFT. All rights reserved.

This manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.