Introduction

This manual provides essential instructions for the safe installation, operation, and maintenance of your ReVent RVS80 Bathroom Exhaust Fan. Please read this manual thoroughly before installation and retain it for future reference.

ReVent RVS80 Bathroom Exhaust Fan unit

Image: The ReVent RVS80 Bathroom Exhaust Fan, showcasing its compact design and exhaust duct connection.

Important Safety Information

Observe the following safety precautions to reduce the risk of fire, electric shock, or injury to persons:

  • Always disconnect power at the service panel before wiring or servicing the unit.
  • Installation must be performed by a qualified electrician in accordance with all local codes and standards.
  • Do not use this fan with any solid-state speed control device.
  • This unit is designed for general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
  • Ensure proper grounding.
  • Do not install in a cooking area.
  • Duct work should be installed with a minimum number of turns and the shortest possible run for optimal performance.

Package Contents

Verify that all components are present before beginning installation:

  • ReVent RVS80 Exhaust Fan Unit
  • Grille Cover
  • Installation Hardware (screws, wire nuts)
  • User Manual (this document)

Setup and Installation

The ReVent RVS80 features a "SheetLock" system designed for easy installation. Follow these steps for proper setup:

  1. Preparation:
    • Turn off power at the circuit breaker before starting any work.
    • Determine the desired location for the fan. Ensure there is sufficient space above the ceiling for the fan housing and ductwork.
    • Cut an opening in the ceiling according to the fan's dimensions (refer to specifications for exact cutout size).
  2. Duct Connection:
    • Connect appropriate ductwork (typically 4-inch round) to the fan's exhaust collar. Secure with duct tape or clamps.
    • Ensure the ductwork leads to the outside of the building, not into an attic or crawl space.
  3. Mounting the Fan (SheetLock System):
    Close-up of SheetLock installation tabs

    Image: A hand demonstrating the "SheetLock" installation tabs, designed to simplify mounting the fan to drywall or ceiling panels.

    • Insert the fan housing into the ceiling opening.
    • Utilize the integrated SheetLock tabs to secure the fan directly to the drywall or ceiling panel. These tabs are designed to hold the fan firmly in place without needing access from above the ceiling joists.
    • Tighten the SheetLock tabs until the fan housing is flush and stable.
  4. Electrical Wiring:
    • Open the wiring compartment cover on the fan housing.
    • Connect the household electrical wires (black to black, white to white, green/bare to ground) using approved wire nuts.
    • Ensure all connections are secure and replace the wiring compartment cover.
  5. Grille Installation:
    Top-down view of the ReVent RVS80 fan grille

    Image: A top-down view of the ReVent RVS80 fan grille, showing its clean, minimalist design that blends with various ceiling aesthetics.

    • Align the grille springs with the slots in the fan housing.
    • Push the grille firmly upwards until the springs engage and hold the grille securely against the ceiling.
  6. Final Check:
    • Restore power at the circuit breaker.
    • Test the fan to ensure it operates correctly.
ReVent RVS80 fan installed in a modern bathroom

Image: The ReVent RVS80 fan discreetly installed in the ceiling of a modern bathroom, above a vanity with a sink and mirror, demonstrating its integrated appearance.

ReVent RVS80 fan installed in a bathroom with a shower

Image: The ReVent RVS80 fan installed in a bathroom ceiling, positioned above a shower area, highlighting its suitability for moisture-prone environments.

Operating Instructions

The ReVent RVS80 exhaust fan is designed for simple operation.

  • Power On/Off: Operate the fan using a standard wall switch connected to the fan's electrical circuit.
  • Usage: Turn on the fan during and after showering or bathing to effectively remove moisture and odors from the bathroom. For optimal moisture removal, allow the fan to run for at least 15-20 minutes after the activity.
ReVent RVS80 fan in a minimalist bathroom setting

Image: The ReVent RVS80 fan integrated into the ceiling of a minimalist bathroom, featuring a floating vanity and a large round mirror, showcasing its unobtrusive design.

ReVent RVS80 fan installed in a laundry room

Image: The ReVent RVS80 fan installed in the ceiling of a laundry room, positioned above a washer and dryer, indicating its versatility for various utility spaces requiring ventilation.

Maintenance

Regular cleaning ensures optimal performance and extends the life of your exhaust fan.

  1. Disconnect Power: Always turn off power at the circuit breaker before cleaning.
  2. Remove Grille: Gently pull down the grille cover to disengage the springs.
  3. Clean Grille: Wash the grille cover with mild soap and water. Rinse thoroughly and dry completely before reinstallation.
  4. Clean Fan Housing: Use a soft cloth or vacuum cleaner with a brush attachment to remove dust and debris from the fan motor and housing. Do not allow water to enter the motor.
  5. Reinstall Grille: Align the grille springs with the slots and push firmly until it snaps into place.
  6. Restore Power: Turn power back on at the circuit breaker.

Frequency: Clean the fan grille and housing every 3-6 months, or more frequently in dusty environments.

Troubleshooting

Refer to the following table for common issues and their solutions:

ProblemPossible CauseSolution
Fan does not operate.No power; loose wiring; faulty switch.Check circuit breaker. Verify wiring connections. Test or replace switch.
Fan is noisy.Loose mounting; debris in fan; damaged motor/blade.Ensure fan is securely mounted. Clean fan housing and blades. If noise persists, contact support.
Poor ventilation.Blocked ductwork; improper duct size; excessive duct length/bends.Inspect ductwork for obstructions. Ensure correct duct size (4-inch). Shorten duct runs and minimize bends.

Specifications

FeatureDetail
ModelRVS80
Air Flow Capacity80 CFM (Cubic Feet Per Minute)
Noise Level0.8 Sones
Power SourceCorded Electric
Room TypeBathroom
Indoor/Outdoor UsageIndoor
Finish TypeWhite Gloss
Control MethodTouch (via external switch)
Item Weight6.62 pounds
Package Dimensions12.17 x 11.73 x 8.27 inches
UPC855448008053
ReVent RVS80 fan in a bright bathroom with natural light

Image: The ReVent RVS80 fan installed in a spacious, brightly lit bathroom with large windows, demonstrating its seamless integration into various ceiling types and room designs.

Warranty Information

ReVent products are manufactured to high-quality standards. For specific warranty details, including coverage period and terms, please refer to the warranty card included with your product or visit the official ReVent website. Keep your purchase receipt as proof of purchase for any warranty claims.

Customer Support

If you have any questions, require technical assistance, or need to report an issue with your ReVent RVS80 exhaust fan, please contact ReVent customer support. Contact information can typically be found on the product packaging or the official ReVent website.

© 2024 ReVent. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.