This manual provides essential instructions for the safe installation, operation, and maintenance of your ReVent RVS80 Bathroom Exhaust Fan. Please read this manual thoroughly before installation and retain it for future reference.

Image: The ReVent RVS80 Bathroom Exhaust Fan, showcasing its compact design and exhaust duct connection.
Important Safety Information
Observe the following safety precautions to reduce the risk of fire, electric shock, or injury to persons:
- Always disconnect power at the service panel before wiring or servicing the unit.
- Installation must be performed by a qualified electrician in accordance with all local codes and standards.
- Do not use this fan with any solid-state speed control device.
- This unit is designed for general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
- Ensure proper grounding.
- Do not install in a cooking area.
- Duct work should be installed with a minimum number of turns and the shortest possible run for optimal performance.
Package Contents
Verify that all components are present before beginning installation:
- ReVent RVS80 Exhaust Fan Unit
- Grille Cover
- Installation Hardware (screws, wire nuts)
- User Manual (this document)
Setup and Installation
The ReVent RVS80 features a "SheetLock" system designed for easy installation. Follow these steps for proper setup:
- Preparation:
- Turn off power at the circuit breaker before starting any work.
- Determine the desired location for the fan. Ensure there is sufficient space above the ceiling for the fan housing and ductwork.
- Cut an opening in the ceiling according to the fan's dimensions (refer to specifications for exact cutout size).
- Duct Connection:
- Connect appropriate ductwork (typically 4-inch round) to the fan's exhaust collar. Secure with duct tape or clamps.
- Ensure the ductwork leads to the outside of the building, not into an attic or crawl space.
- Mounting the Fan (SheetLock System):

Image: A hand demonstrating the "SheetLock" installation tabs, designed to simplify mounting the fan to drywall or ceiling panels.
- Insert the fan housing into the ceiling opening.
- Utilize the integrated SheetLock tabs to secure the fan directly to the drywall or ceiling panel. These tabs are designed to hold the fan firmly in place without needing access from above the ceiling joists.
- Tighten the SheetLock tabs until the fan housing is flush and stable.
- Electrical Wiring:
- Open the wiring compartment cover on the fan housing.
- Connect the household electrical wires (black to black, white to white, green/bare to ground) using approved wire nuts.
- Ensure all connections are secure and replace the wiring compartment cover.
- Grille Installation:

Image: A top-down view of the ReVent RVS80 fan grille, showing its clean, minimalist design that blends with various ceiling aesthetics.
- Align the grille springs with the slots in the fan housing.
- Push the grille firmly upwards until the springs engage and hold the grille securely against the ceiling.
- Final Check:
- Restore power at the circuit breaker.
- Test the fan to ensure it operates correctly.

Image: The ReVent RVS80 fan discreetly installed in the ceiling of a modern bathroom, above a vanity with a sink and mirror, demonstrating its integrated appearance.

Image: The ReVent RVS80 fan installed in a bathroom ceiling, positioned above a shower area, highlighting its suitability for moisture-prone environments.
Operating Instructions
The ReVent RVS80 exhaust fan is designed for simple operation.
- Power On/Off: Operate the fan using a standard wall switch connected to the fan's electrical circuit.
- Usage: Turn on the fan during and after showering or bathing to effectively remove moisture and odors from the bathroom. For optimal moisture removal, allow the fan to run for at least 15-20 minutes after the activity.

Image: The ReVent RVS80 fan integrated into the ceiling of a minimalist bathroom, featuring a floating vanity and a large round mirror, showcasing its unobtrusive design.

Image: The ReVent RVS80 fan installed in the ceiling of a laundry room, positioned above a washer and dryer, indicating its versatility for various utility spaces requiring ventilation.
Maintenance
Regular cleaning ensures optimal performance and extends the life of your exhaust fan.
- Disconnect Power: Always turn off power at the circuit breaker before cleaning.
- Remove Grille: Gently pull down the grille cover to disengage the springs.
- Clean Grille: Wash the grille cover with mild soap and water. Rinse thoroughly and dry completely before reinstallation.
- Clean Fan Housing: Use a soft cloth or vacuum cleaner with a brush attachment to remove dust and debris from the fan motor and housing. Do not allow water to enter the motor.
- Reinstall Grille: Align the grille springs with the slots and push firmly until it snaps into place.
- Restore Power: Turn power back on at the circuit breaker.
Frequency: Clean the fan grille and housing every 3-6 months, or more frequently in dusty environments.
Troubleshooting
Refer to the following table for common issues and their solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Fan does not operate. | No power; loose wiring; faulty switch. | Check circuit breaker. Verify wiring connections. Test or replace switch. |
| Fan is noisy. | Loose mounting; debris in fan; damaged motor/blade. | Ensure fan is securely mounted. Clean fan housing and blades. If noise persists, contact support. |
| Poor ventilation. | Blocked ductwork; improper duct size; excessive duct length/bends. | Inspect ductwork for obstructions. Ensure correct duct size (4-inch). Shorten duct runs and minimize bends. |
Specifications
| Feature | Detail |
|---|---|
| Model | RVS80 |
| Air Flow Capacity | 80 CFM (Cubic Feet Per Minute) |
| Noise Level | 0.8 Sones |
| Power Source | Corded Electric |
| Room Type | Bathroom |
| Indoor/Outdoor Usage | Indoor |
| Finish Type | White Gloss |
| Control Method | Touch (via external switch) |
| Item Weight | 6.62 pounds |
| Package Dimensions | 12.17 x 11.73 x 8.27 inches |
| UPC | 855448008053 |

Image: The ReVent RVS80 fan installed in a spacious, brightly lit bathroom with large windows, demonstrating its seamless integration into various ceiling types and room designs.
Warranty Information
ReVent products are manufactured to high-quality standards. For specific warranty details, including coverage period and terms, please refer to the warranty card included with your product or visit the official ReVent website. Keep your purchase receipt as proof of purchase for any warranty claims.
Customer Support
If you have any questions, require technical assistance, or need to report an issue with your ReVent RVS80 exhaust fan, please contact ReVent customer support. Contact information can typically be found on the product packaging or the official ReVent website.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.