Thank you for purchasing the allen + roth Remy Flushmount Ceiling Fixture. This manual provides detailed instructions for the safe installation, operation, and maintenance of your new lighting fixture. Please read all instructions carefully before beginning installation and retain this manual for future reference.

The Remy flushmount fixture features a textured black frame with weathered wood accents and a mesh design, creating an industrial aesthetic. It is designed for indoor use and requires three candelabra base bulbs (E12), 60 watts maximum each, which are sold separately.

2. Safety Information

For your safety, always remember to:

  • WARNING: Disconnect power at the main fuse or circuit breaker box before beginning installation or performing any maintenance.
  • Consult a qualified electrician if you are unsure about the installation process.
  • Ensure all electrical connections comply with local codes and ordinances, as well as the National Electric Code (NEC).
  • Do not exceed the maximum wattage specified for the bulbs (60 watts per bulb).
  • Handle the fixture with care to avoid damage.
  • This fixture is designed for indoor use only.

3. Package Contents

Carefully unpack your fixture and check that all parts are included. If any parts are missing or damaged, do not attempt to assemble or install the fixture. Contact customer service for assistance.

  • Flushmount Ceiling Fixture (1)
  • Mounting Hardware (e.g., mounting bracket, screws, wire nuts) (1 set)
  • Instruction Manual (1)

Note: Bulbs are not included. This fixture requires three candelabra base (E12) bulbs, 60 watts maximum each.

4. Setup and Installation

Follow these steps for proper installation of your flushmount ceiling fixture.

4.1 Tools Required (Not Included)

  • Screwdriver (Phillips and/or Flathead)
  • Wire Strippers
  • Electrical Tape
  • Ladder

4.2 Pre-Installation

  1. Turn off power at the circuit breaker or fuse box.
  2. Carefully remove the old fixture (if applicable).
  3. Unpack the new fixture and lay out all parts on a clean, flat surface.

4.3 Mounting the Fixture

  1. Attach the mounting bracket to the junction box in the ceiling using the provided screws. Ensure the bracket is securely fastened.
  2. Connect the electrical wires:
    • Connect the bare copper or green ground wire from the fixture to the ground wire from the junction box using a wire nut.
    • Connect the white (neutral) wire from the fixture to the white (neutral) wire from the junction box using a wire nut.
    • Connect the black (hot) wire from the fixture to the black (hot) wire from the junction box using a wire nut.
    • Wrap electrical tape around each wire nut connection for added security.
  3. Carefully tuck all wires into the junction box.
  4. Align the fixture base with the mounting bracket and secure it with the provided screws.

4.4 Bulb Installation

  1. Screw three candelabra base (E12) bulbs (not included) into the sockets. Do not exceed 60 watts per bulb.
Remy Flushmount Ceiling Fixture with Dimensions

Image 1: The allen + roth Remy Flushmount Ceiling Fixture showing its dimensions of 14 inches length, 14 inches width, and 6 inches height. This image provides a visual reference for planning installation space.

5. Operating Instructions

  1. Once installation is complete, restore power at the circuit breaker or fuse box.
  2. Turn on the light switch connected to the fixture.
  3. This fixture is dimmable and compatible with standard wall dimmers (sold separately). Ensure you use dimmable bulbs if you intend to use a dimmer switch.
  4. While the product specifications mention "App" and "Remote Control" for control methods, these typically refer to optional smart home integrations or accessories not included with the basic fixture. The primary control is via a standard wall switch.

6. Maintenance

To maintain the appearance and functionality of your fixture:

  • WARNING: Always turn off power to the fixture before cleaning.
  • Wipe the fixture with a soft, dry cloth.
  • Do not use abrasive cleaners, solvents, or polishes as they may damage the finish.
  • Periodically check all electrical connections for tightness.

7. Troubleshooting

If you experience issues with your fixture, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Light does not turn on.
  • Power is off at the breaker.
  • Loose wire connections.
  • Faulty bulb.
  • Faulty wall switch.
  • Check circuit breaker/fuse.
  • Verify all wire connections are secure (ensure power is off first).
  • Replace bulb with a new one.
  • Test wall switch or consult an electrician.
Light flickers or dims improperly.
  • Loose wire connections.
  • Incorrect bulb type for dimmer.
  • Incompatible dimmer switch.
  • Verify all wire connections are secure (ensure power is off first).
  • Ensure dimmable bulbs are used with a dimmer switch.
  • Consult an electrician to check dimmer switch compatibility.

If the problem persists after trying these solutions, contact a qualified electrician or customer support.

8. Specifications

Remy Flushmount Ceiling Fixture

Image 2: The allen + roth Remy Flushmount Ceiling Fixture, showcasing its industrial design with a black frame, weathered wood accents, and mesh details.

Brandallen + roth
Model NameRemy
Fixture TypeFlush Mount Ceiling Light
ColorBlack
MaterialAlloy Steel, Wood
Product Dimensions14"L x 14"W x 6"H
Indoor/Outdoor UsageIndoor
Power SourceCorded Electric
Number of Light Sources3
Bulb Base TypeCandelabra (E12)
Max Wattage per Bulb60 Watts
DimmableYes (compatible with standard wall dimmer)
Item Weight8.43 pounds
UPC782042315716

9. Warranty and Support

Specific warranty information for this product may vary. Please refer to the documentation included with your purchase or contact the retailer or manufacturer directly for details regarding warranty coverage and customer support.

For technical assistance or inquiries, please contact allen + roth customer service through their official website or the retailer where the product was purchased.

Related Documents - Remy

Preview allen + roth Flushmount Ceiling Fixture Model #25604-030 Installation Guide
Comprehensive installation guide for the allen + roth Flushmount Ceiling Fixture (Model #25604-030), including package contents, hardware details, safety warnings, step-by-step assembly instructions, care and maintenance, troubleshooting, and warranty information.
Preview allen + roth LED Flushmount Ceiling Fixture Installation and Safety Guide
Comprehensive guide for the allen + roth LED Flushmount Ceiling Fixture (Model #CLL11BNK, CLL11MBK), covering safety information, preparation, assembly instructions, care, maintenance, troubleshooting, and warranty details.
Preview Allen + Roth Flushmount Ceiling Fixture Installation Guide
Step-by-step instructions and safety information for installing the Allen + Roth Flushmount Ceiling Fixture (Model #IXO8292A). Includes parts list, troubleshooting, and warranty information.
Preview Allen + Roth LED Flushmount Ceiling Fixture Installation Guide and Manual
Comprehensive guide for installing and maintaining the Allen + Roth LED Flushmount Ceiling Fixture (Model MXL1089-LED35K9027B/N). Includes safety, troubleshooting, care, and warranty information.
Preview Allen + Roth Flushmount Ceiling Fixture Installation and Care Guide
Comprehensive guide for installing and maintaining the Allen + Roth Flushmount Ceiling Fixture. Includes safety information, parts list, and step-by-step installation instructions.
Preview Allen + Roth Aurelis LED Flushmount Ceiling Fixture Installation Guide
Easy-to-follow instructions for installing the Allen + Roth Aurelis LED Flushmount Ceiling Fixture. Includes troubleshooting, care, maintenance, and warranty information.