1. Product Overview and Features

The Thincol BEM-X-50-3U-D is a robust 3-layer LED signal tower light designed for industrial warning applications. It features continuous bright illumination in red, orange, and green, an integrated audible alarm, and a flexible rotating base for versatile installation.

Thincol BEM-X-50-3U-D LED Signal Tower Light

Figure 1: Thincol BEM-X-50-3U-D LED Signal Tower Light with rotating base.

Key Features:

  • Three-Color LED Warning Light: Integrated multi-layer warning light with continuous red, orange, and green illumination, ensuring uniform light distribution.
  • Light-Transmitting Lampshade: The lampshade is constructed from heat and shock-resistant polycarbonate, providing durability and excellent light transmission.
  • 85dB Audible and Visual Alert: Features a built-in buzzer that provides a clear and loud warning tone up to 85dB.
  • Rotating Base: The rotating base allows for 180-degree barrier-free positioning, offering flexible installation and usage options.
  • Wide Application Scope: Suitable for machine tools, industrial machinery, construction sites, security vehicles, and public areas.
85dB Sound Light Alert Warning

Figure 2: Illustration of the 85dB audible alarm feature.

Light-Transmitting Lampshade

Figure 3: Close-up of the durable, light-transmitting polycarbonate lampshade.

Rotating Base for 180-degree positioning

Figure 4: The rotating disc base allows for flexible 180-degree adjustment.

Product Video:

Video 1: Demonstration of the LED Signal Tower Light in operation.

2. Setup and Installation

Follow these steps for proper installation of your signal tower light. Ensure power is disconnected before beginning any installation or wiring.

Mounting the Unit:

  1. Select a suitable mounting location that is stable and provides clear visibility of the warning light.
  2. Use the provided mounting base to mark the drilling points on the surface.
  3. Drill appropriate holes and secure the base using screws (not included, ensure they are suitable for your mounting surface).
  4. Attach the signal tower light to the secured base, ensuring it is firmly in place. The rotating base allows for angle adjustment after mounting.

Wiring Instructions:

The signal tower light operates on DC 24V. Refer to the wiring diagram below for correct connections. Use high-quality cables for reliable operation.

High Quality Cable and Wire Identification

Figure 5: High-quality cables with color distinction for easy identification.

Product Wiring Diagram

Figure 6: Detailed wiring diagram for the Thincol BEM-X-50-3U-D signal tower light.

  • Red Wire: Connects to the power source for the red light.
  • Yellow Wire: Connects to the power source for the orange light.
  • Green Wire: Connects to the power source for the green light.
  • Brown Wire: Connects to the power source for the buzzer alarm.
  • Gray Wire: Common/Public line (no positive or negative pole distinction). Connect to the common return of your DC 24V power supply.

Ensure all connections are secure and insulated to prevent short circuits. Verify the power supply is DC 24V before connecting.

3. Operation

Once installed and wired correctly, the Thincol BEM-X-50-3U-D signal tower light is ready for operation.

  • Power On: Apply DC 24V power to the respective color wires (red, yellow, green) to activate the corresponding light segments.
  • Light Function: Each light segment (red, orange, green) provides a constant bright illumination when powered.
  • Alarm Function: Apply DC 24V power to the brown wire to activate the integrated buzzer, producing an audible alarm up to 85dB.
  • Adjusting Angle: The rotating base allows you to adjust the angle of the light tower by up to 180 degrees to optimize visibility.

4. Maintenance

Regular maintenance ensures the longevity and optimal performance of your signal tower light.

  • Cleaning: Periodically clean the lampshade with a soft, damp cloth. Avoid abrasive cleaners or solvents that could damage the polycarbonate material.
  • Inspection: Regularly inspect the wiring for any signs of wear, damage, or loose connections. Ensure the mounting base is secure.
  • Environmental Conditions: Ensure the operating environment is within the specified temperature and humidity ranges to prevent damage.

5. Troubleshooting

If you encounter issues with your signal tower light, refer to the following common problems and solutions:

  • Light Segment Not Illuminating:
    • Check the DC 24V power supply to the specific color wire.
    • Verify the wiring connection for that segment is secure.
    • Ensure the power source is active.
  • Buzzer Alarm Not Sounding:
    • Check the DC 24V power supply to the brown wire.
    • Verify the wiring connection for the buzzer is secure.
  • Intermittent Operation:
    • Inspect all wiring connections for looseness or corrosion.
    • Ensure the power supply is stable and providing consistent DC 24V.

If problems persist after performing these checks, please contact customer support.

6. Technical Specifications

SpecificationDetail
ModelBEM-X-50-3U-D
Operating VoltageDC 24V
Power Consumption<3 W
Light ColorsRed, Orange, Green
Light FormConstant Bright
Alarm SoundAudible Alarm (Buzzer)
Alarm VolumeUp to 85dB
Installation MethodFoldable Support Base (Rotating)
Total HeightApprox. 280 mm (11.0 inches)
Tube DiameterApprox. 50 mm (2.0 inches)
Base DiameterApprox. 60 mm (2.4 inches)
MaterialPolycarbonate (PC)
Finish TypePolished
Light Source TypeLED (Light Emitting Diode)
Mounting TypePole Mount
Number of Sockets3
Batteries IncludedNo
Country of OriginChina

7. Warranty Information

This Thincol product is covered by a standard manufacturer's warranty against defects in materials and workmanship. The warranty period typically begins from the date of purchase. Please retain your proof of purchase for warranty claims. For specific warranty terms and conditions, refer to the documentation provided at the time of purchase or contact customer support.

8. Customer Support

For technical assistance, troubleshooting, or any questions regarding your Thincol BEM-X-50-3U-D LED Signal Tower Light, please contact our customer support team. Have your product model number and purchase information ready when you call or email.

Contact Information:
Please refer to the seller's contact details on your purchase platform or packaging for the most up-to-date support information.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.