Reversomatic RI-200

Reversomatic RI Series 5" Inline Duct Ventilation Exhaust Fan RI-200 User Manual

Model: RI-200

1. Introduction

The Reversomatic RI Series 5" Inline Duct Ventilation Exhaust Fan, model RI-200, is engineered for efficient and quiet continuous operation in various settings. This fan is designed to maximize airflow and efficiency while minimizing noise levels, making it suitable for general purpose ventilation in high-rise condominiums, office buildings, schools, and boardrooms. Its low-profile construction simplifies installation in confined spaces.

Key features include a self-cleaning, non-overloading wheel and a well-balanced backward-curved motor impeller assembly. The unit is constructed from quality deep-stretch cold rolling steel and includes mounting brackets for versatile installation.

2. Safety Information

Please read and understand all instructions before installing, operating, or performing maintenance on this product. Failure to follow these instructions may result in electric shock, fire, property damage, or personal injury.

3. Package Contents

Verify that all components are present before beginning installation:

4. Setup and Installation

The RI-200 fan is designed for easy installation in various ducting systems. Mounting brackets are included for secure attachment to walls or trusses.

Reversomatic RI-200 Inline Duct Fan

Figure 4.1: The Reversomatic RI Series 5" Inline Duct Ventilation Exhaust Fan (RI-200). This image shows the grey cylindrical fan unit with a black electrical box attached to its side, and the duct connections visible at either end.

Installation Steps:

  1. Planning: Determine the optimal location for the fan within your ducting system. Consider accessibility for future maintenance and ensure adequate space for airflow.
  2. Mounting: Use the provided mounting brackets to securely attach the fan to a stable surface, such as a wall stud, ceiling joist, or truss. Ensure the fan is level and firmly secured to prevent vibration and noise.
  3. Duct Connection: Connect the appropriate size ducting (5-inch diameter) to both inlet and outlet ports of the fan. Use duct clamps or tape to ensure airtight connections.
  4. Electrical Connection: Connect the fan's power cord to a suitable electrical outlet. Ensure the power supply matches the fan's voltage requirements. If hardwiring, consult a qualified electrician to ensure proper and safe connection according to local electrical codes.
  5. Testing: Once installed, turn on the power and test the fan's operation. Verify that air is moving through the duct system as intended and check for any unusual noises or vibrations.

5. Operating Instructions

The Reversomatic RI-200 fan is designed for continuous, quiet operation. Once properly installed and connected to power, the fan will begin to move air through your ventilation system.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your RI-200 fan. The fan features a self-cleaning, non-overloading wheel, which reduces the frequency of manual cleaning.

7. Troubleshooting

If you encounter issues with your Reversomatic RI-200 fan, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Fan does not turn on.No power supply; loose wiring; faulty switch.Check power outlet and circuit breaker. Ensure all wiring connections are secure. Test the switch.
Reduced airflow.Duct blockage; dirty impeller; incorrect duct size.Inspect ducts for obstructions. Clean the impeller if necessary (after disconnecting power). Ensure 5-inch ducts are used.
Excessive noise or vibration.Loose mounting; debris in fan; damaged impeller.Tighten mounting brackets. Disconnect power and check for debris. If impeller is damaged, contact support.
Fan runs intermittently.Loose electrical connection; overheating.Check all electrical connections. Ensure adequate ventilation around the fan to prevent overheating.

If the problem persists after attempting these solutions, please contact Reversomatic customer support.

8. Specifications

AttributeDetail
BrandReversomatic
ModelRI-200
Electric Fan DesignExhaust Fan
StyleModern
Room TypeOffice (also suitable for high-rise condominiums, schools, boardrooms)
Special FeatureQuiet, Self Cleaning
Recommended UsesExhausting
Included ComponentsCord, Mounting Brackets
Blade MaterialPlastic
ManufacturerReversomatic
UPC723284329062
ASINB08J1M4MBW
Date First AvailableSeptember 14, 2020
OriginMade in Canada

9. Warranty Information

Reversomatic products are manufactured to high standards. For specific warranty terms and conditions applicable to your RI-200 fan, please refer to the warranty card included with your purchase or visit the official Reversomatic website. Keep your proof of purchase for warranty claims.

10. Customer Support

For technical assistance, troubleshooting not covered in this manual, or parts inquiries, please contact Reversomatic customer support. Contact information can typically be found on the manufacturer's official website or on the product packaging.

Manufacturer: Reversomatic

Related Documents - RI-200

Preview Reversomatic HRV/ERV Intake and Exhaust Vents: TVG-150 and TV-200
Technical specifications and installation details for Reversomatic's Triple Vent (TVG-150) and Triple Vent (TV-200) models, designed for HRV/ERV systems with extruded aluminum grilles.
Preview Reversomatic Triple Vent (TV-200) HRV/ERV Intake and Exhaust Vent Installation and Specifications
Detailed specifications and installation information for the Reversomatic Triple Vent (TV-200), an HRV/ERV intake and exhaust vent designed for window panel installation. Includes performance data, dimensions, and material details.
Preview Range Hood Installation Instructions by Reversomatic
Detailed installation guide for Reversomatic range hoods, covering cabinet preparation, ductwork, and electrical wiring.
Preview Reversomatic RERV-S200 Enthalpy Core ERV - Specifications and Installation
Detailed specifications, features, performance data, and installation options for the Reversomatic RERV-S200 Energy Recovery Ventilator (ERV) with Enthalpy Core.
Preview HRV/ERV Installation and Operation Instructions
Comprehensive installation and operation instructions for Reversomatic HRV/ERV units, including RHRV-C100PECM and RERV-C100ECM models. Covers safety, wiring diagrams, typical installations, air flow balancing, maintenance, and troubleshooting.
Preview Reversomatic RERV-SL100ECM ERV: Installation & Operating Guide
Comprehensive installation and operating instructions for the Reversomatic RERV-SL100ECM Energy Recovery Ventilator (ERV). This guide covers safety precautions, parts list, wiring diagrams, installation procedures, air flow balancing, maintenance, and troubleshooting for optimal performance and energy efficiency.