1. Introduction
Thank you for choosing the NOYAFA NF-271 Laser Distance Measure. This device is designed for precise and efficient measurement of distances, areas, and volumes. Equipped with a clear LCD backlit display, a bubble level, and various measurement modes including Pythagorean, it is a versatile tool for professionals and DIY enthusiasts. This manual provides detailed instructions for safe and effective use of your device.

Image: The NOYAFA NF-271 Laser Distance Measure, showcasing its compact red and black design with a digital display.
2. Safety Information
Please read all safety instructions carefully before using the device. Failure to follow these instructions may result in laser radiation exposure, electric shock, fire, or serious injury.
2.1 Laser Safety
- CAUTION: Laser Radiation. Do not stare into the beam.
- This device uses a Class 2 laser. Avoid direct eye exposure.
- Do not aim the laser beam at people or animals.
- Do not modify the laser device in any way.
- Keep the device out of reach of children.
2.2 General Safety
- Do not use the device in explosive environments or near flammable liquids, gases, or dust.
- Protect the device from moisture and direct sunlight.
- Do not attempt to disassemble or repair the device yourself. Contact qualified service personnel.
- Use only specified batteries. Ensure correct polarity when inserting.
3. Product Features
- High-precision laser measurement.
- Multiple measurement modes: Single distance, Area, Volume, Pythagorean (direct and secondary).
- Built-in bubble level for accurate horizontal alignment.
- LCD backlit display for clear readings in various lighting conditions.
- Historical data storage.
- Dust-proof and anti-fall design for durability.
- Compact and portable.
4. Package Contents
- NOYAFA NF-271 Laser Distance Measure
- User Manual
- (Batteries are NOT included)

Image: The NOYAFA NF-271 device shown alongside its retail packaging and the included instruction manual.
5. Setup
5.1 Battery Installation
The NF-271 requires batteries for operation. Please follow these steps:
- Locate the battery compartment cover on the back of the device.
- Slide or unclip the cover to open the compartment.
- Insert the required batteries (e.g., AAA batteries, check device for specific type) ensuring correct polarity (+ and -) as indicated inside the compartment.
- Close the battery compartment cover securely.
6. Operating Instructions
6.1 Overview of Controls

Image: A close-up view of the NOYAFA NF-271, with labels pointing to each button and its primary function: Measure, Menu, Add, Subtract, Benchmark & Unit Switch, Record Query & Setting, and Power & Clear.
- MEAS Button: Initiates measurement, confirms selection.
- Menu Button: Accesses measurement modes (Area, Volume, Pythagorean).
- + Button: Adds measurements.
- - Button: Subtracts measurements.
- Benchmark & Unit Switch Button: Changes measurement reference point (front/rear) and units (m/ft/in).
- Record Query & Setting Button: Views historical measurements and accesses settings.
- Power & Clear Button: Powers on/off, clears current measurement.
6.2 Basic Distance Measurement
- Press the Power & Clear button to turn on the device.
- Aim the laser at the target point.
- Press the MEAS button. The measured distance will be displayed on the screen.
6.3 Area Measurement
To measure the area of a surface:
- Press the Menu button until the Area icon (a square) appears on the display.
- Press MEAS to measure the first side (e.g., length).
- Press MEAS again to measure the second side (e.g., width).
- The device will automatically calculate and display the area.

Image: A hand holding the NOYAFA NF-271, demonstrating an area measurement. The laser beam is visible, and the display shows length, width, and the calculated area (20.327 m²).
6.4 Volume Measurement
To measure the volume of a space:
- Press the Menu button until the Volume icon (a cube) appears on the display.
- Press MEAS to measure the length.
- Press MEAS again to measure the width.
- Press MEAS a third time to measure the height.
- The device will automatically calculate and display the volume.

Image: A hand holding the NOYAFA NF-271, demonstrating a volume measurement. The display shows three individual measurements (length, width, height) and the calculated volume (32.620 m³).
6.5 Pythagorean Measurement
The Pythagorean mode allows indirect measurement of heights or distances using the Pythagorean theorem.
6.5.1 Direct Pythagorean Measurement (Single Pythagorean)
Used to calculate the height of an object when you can measure the hypotenuse and one leg of a right triangle.
- Press the Menu button until the single Pythagorean icon appears (a right triangle with the hypotenuse highlighted).
- Measure the hypotenuse (distance from the device to the top of the object).
- Measure the base (horizontal distance from the device to the bottom of the object).
- The device will calculate and display the height.

Image: A person using the NOYAFA NF-271 to perform a Pythagorean measurement, aiming the laser to calculate height. The display shows the measured hypotenuse and base, and the calculated height.
6.5.2 Secondary Pythagorean Measurement
Used for more complex height calculations, often when the base cannot be directly measured from the device's position.
- Press the Menu button until the secondary Pythagorean icon appears (two right triangles sharing a common leg).
- Measure the first hypotenuse (distance from device to top of object).
- Measure the second hypotenuse (distance from device to bottom of object).
- The device will calculate and display the height difference.
6.6 Unit Switching and Benchmark
- Press the Benchmark & Unit Switch button to cycle through measurement units (meters, feet, inches).
- Hold the Benchmark & Unit Switch button to change the measurement reference point (from the front or rear of the device).
6.7 Historical Record
The device stores recent measurements. Press the Record Query & Setting button to view previous readings.
6.8 Product Demonstration Video
Video: A demonstration of the NOYAFA NF-271 Laser Distance Meter, showcasing its features such as historical record, backlight display, dust-proof and anti-fall capabilities, and various measurement modes including area, volume, and Pythagorean measurements.
7. Maintenance
- Clean the device with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Keep the laser lens clean and free of dust or debris.
- Remove batteries if the device will not be used for an extended period to prevent leakage.
- Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not turn on. | Low or dead batteries; incorrect battery polarity. | Replace batteries; check battery orientation. |
| Inaccurate measurements. | Laser lens dirty; unstable measurement surface; strong light interference. | Clean lens; ensure stable surface; measure in less bright conditions or use a target plate. |
| Display is dim or flickering. | Low battery power. | Replace batteries. |
| Laser beam is not visible. | Device off; very bright ambient light. | Turn on device; measure in lower light conditions. |
9. Specifications
| Feature | Detail |
|---|---|
| Brand | NOYAFA |
| Model | NF-271 |
| Material | Plastic |
| Water Resistance Level | Waterproof |
| Item Package Dimensions | 7.28 x 3.62 x 1.65 inches |
| Package Weight | 0.22 Kilograms |
| Batteries Included | No |
| First Available Date | August 30, 2020 |

Image: The NOYAFA NF-271 device with its approximate dimensions indicated: 115mm length, 51mm width, and 23mm thickness.
10. Warranty and Support
For warranty information or technical support, please refer to the contact details provided with your purchase or visit the official NOYAFA website. Keep your purchase receipt as proof of purchase for warranty claims.