1. Introduction
The EBM R2E150-AN91-22 Smoke Remover is an essential component designed for efficient smoke extraction in pellet ovens and biomass pans. This manual provides critical information for the proper installation, safe operation, and routine maintenance of your smoke remover, ensuring optimal performance and longevity. Please read this manual thoroughly before attempting any installation or operation.
2. Product Overview
The EBM R2E150-AN91-22 features a robust design, including an impeller made of AISI 430 steel, and is equipped with a lobby effect sensor (encoder) for precise control. It is engineered to handle a maximum flow rate of 185 m³/h, ensuring effective smoke removal from your heating appliance.

This image displays the EBM R2E150-AN91-22 Smoke Remover unit. It features a metallic, disc-shaped motor housing with a central shaft, surrounded by electrical wiring, including a capacitor and various connectors. The unit is designed for smoke extraction in heating systems.
3. Specifications
| Feature | Detail |
|---|---|
| Manufacturer | EBM |
| Model | EBM R2E150-AN91-22 |
| Weight | 1.75 kg |
| Motor | M2E068-BF |
| Power Supply | 230V AC 50Hz |
| Power | 32W |
| Power Consumption | 0.14A |
| Impeller Diameter | 150mm |
| Tube Height | 20 mm |
| Revolutions Per Minute (RPM) | 2400 rpm |
| Flow Rate | 136 m³/h |
| Flange Diameter | 165mm |
| Capacitor | 1 µF 400V (Standard: S0) |
| Ambient Temperature Range | Min. -25°C, Max. 80°C |
| Number of Blades | 6 |
| Rotation Direction | Left (as seen on the rotor) |
| Protection Type | IP44 (depending on mounting and position) |
| Insulation Class | B |
4. Compatibility
The EBM R2E150-AN91-22 Smoke Remover is designed to replace or be compatible with various models. Always verify compatibility with your specific appliance before installation.
Replacement for:
- AACO ST73M 150.OR.20.32
- EBM R2E150-AN91-13/15/19/20/21/22/24/37/54
Suitable for Stoves (Part Number 14706003-150201):
- ANSELMO COLA REF: 453552201, 599001080, 453554120, 599000680
- Arc Ref 1611905484 models: Lexia, Lexia jr, Lexia jr plus, Lexia plus, Hot Plus, Hetna jr, Hetna jr plus, Circle, Circle Plus, Channalized circle plus, Circle jr Plus, Water Circle Medium, Water Circle Small
- MONTEGRAPE fireplaces: 1000, 5000, 6000, 7000, 8000, 10000, 15000, Montegrappa Pellets (Note: Verify wiring compatibility as differences may exist.)
- CLAM Cod. 05010004 models: Brooklyn, New York, Vienna, Paris, Pulsar, Niagara, Retro, Vintage, Victoria 20KW, Victory 26KW
- CLAM Cod. 05010378 models: Elegance, Oslo, Style, Time
- CLAM Cod. 05020771 model: Lawns
5. Setup and Installation
Installation of the EBM R2E150-AN91-22 Smoke Remover should be performed by a qualified and certified technician. Improper installation can lead to malfunction, damage, or safety hazards. Always ensure the main power supply to the appliance is disconnected before beginning any installation work.
- Refer to the specific appliance's instruction manual for detailed wiring diagrams and mounting procedures.
- Ensure all electrical connections are secure and comply with local electrical codes.
- Verify that the unit is correctly oriented for proper smoke extraction as indicated by the appliance manufacturer.
6. Operating Instructions
The EBM R2E150-AN91-22 Smoke Remover operates automatically as an integral part of your pellet oven or biomass pan system. Once installed and the appliance is powered on, the smoke remover will activate as required to maintain proper ventilation and smoke evacuation.
- Ensure the heating system is properly configured and maintained according to its own manual for optimal performance of the smoke remover.
- Do not obstruct the air intake or exhaust vents of the smoke remover or the appliance.
7. Maintenance
Regular maintenance helps ensure the longevity and efficient operation of your smoke remover. Always disconnect the main power supply to the appliance before performing any maintenance.
- Inspection: Periodically inspect the smoke remover for any signs of dust accumulation, debris, or physical damage.
- Cleaning: If dust or debris is present, carefully clean the impeller and housing using a soft brush or vacuum cleaner. Avoid using liquids or abrasive cleaners.
- Professional Service: For any complex cleaning, repairs, or internal inspections, consult a qualified technician.
8. Troubleshooting
If you experience issues with your EBM R2E150-AN91-22 Smoke Remover, consider the following basic troubleshooting steps:
- No Power: Check the main power supply to the appliance and ensure all electrical connections to the smoke remover are secure.
- Reduced Performance: Inspect the impeller and air pathways for any obstructions (e.g., ash, debris) that might impede airflow.
- Unusual Noise: Disconnect power and carefully check for any loose components or foreign objects within the unit.
For persistent problems or issues beyond basic troubleshooting, contact a qualified service professional for assistance.
9. Safety Information
Adherence to safety guidelines is crucial when handling and operating the smoke remover.
- Always disconnect the main power supply before installing, cleaning, or performing any maintenance on the unit.
- Avoid contact with moving parts during operation.
- Ensure proper grounding of the electrical system.
- This unit operates at 230V AC; improper handling can result in severe electric shock.
- Do not operate the unit if it is damaged or if any electrical wires are exposed.
10. Warranty and Support
For technical support, compatibility inquiries, or warranty information, please refer to your purchase documentation or contact the product supplier. Specific warranty terms may vary depending on the retailer and region of purchase.