Thomson Cardio A6

THOMSON Cardio A6 Electronic Arm Blood Pressure Monitor User Manual

1. Product Overview

The THOMSON Cardio A6 is an advanced electronic arm blood pressure monitor designed for accurate and reliable measurement of systolic and diastolic blood pressure, as well as pulse rate. It features a large LCD display for easy reading, a memory function for tracking measurements over time for multiple users, and arrhythmia detection. This device is suitable for home use and provides essential health monitoring capabilities.

2. Safety Information

Please read all instructions carefully before using the device. Keep this manual for future reference.

3. Product Components

The THOMSON Cardio A6 package typically includes the following items:

THOMSON Cardio A6 Blood Pressure Monitor with cuff, USB cable, and power adapter

Figure 3.1: THOMSON Cardio A6 Blood Pressure Monitor unit with its arm cuff, USB power cable, and wall adapter. The display shows numerical readings.

THOMSON Cardio A6 Blood Pressure Monitor with cuff

Figure 3.2: Close-up view of the THOMSON Cardio A6 Blood Pressure Monitor and its attached arm cuff. The device features a large LCD screen and clearly labeled buttons.

THOMSON Cardio A6 Blood Pressure Monitor retail packaging

Figure 3.3: Retail packaging for the THOMSON Cardio A6 Blood Pressure Monitor, showing the product image and key features such as multi-user support and accurate detection.

4. Setup

Follow these steps to set up your blood pressure monitor for first use:

  1. Power Supply:
    • USB Power: Connect the provided USB cable to the monitor's USB port and plug the other end into a compatible USB power adapter (not always included) or a computer USB port.
    • Battery Power (Optional): If using batteries (not included), open the battery compartment on the back of the unit and insert 4 "AAA" alkaline batteries, ensuring correct polarity (+/-).
  2. Attach the Cuff: Insert the air tube connector from the arm cuff firmly into the air jack on the side of the monitor unit.
  3. Set Date and Time: When powered on for the first time, the device may prompt you to set the date and time. Use the "SET" button to navigate and adjust values, and the "MEM" button to confirm.
  4. User Selection: If the device supports multiple users, select the desired user profile (e.g., User 1 or User 2) before taking a measurement.

5. Operating Instructions

Taking a Measurement:

  1. Preparation: Sit comfortably with your back supported and feet flat on the floor. Rest your arm on a table so the cuff is at heart level. Avoid talking or moving during the measurement.
  2. Apply the Cuff: Wrap the arm cuff around your bare upper arm, approximately 1-2 cm above the elbow joint. Ensure the air tube runs down the center of your arm in line with your middle finger. The cuff should be snug but not too tight.
  3. Start Measurement: Press the START/STOP button. The cuff will automatically inflate, and the measurement will begin.
  4. Read Results: Once the measurement is complete, the systolic pressure (SYS), diastolic pressure (DIA), and pulse rate (PUL/min) will be displayed on the LCD screen.
  5. Power Off: Press the START/STOP button again to turn off the device, or it will automatically shut off after a period of inactivity.

Memory Function:

The THOMSON Cardio A6 stores up to 90 measurements for two users, allowing you to track your blood pressure trends over time.

Arrhythmia Detection:

If an irregular heartbeat is detected during the measurement, a specific symbol (e.g., a heart icon with irregular beats) may appear on the display. If this symbol appears frequently, consult your doctor.

6. Maintenance and Care

7. Troubleshooting

ProblemPossible CauseSolution
Device does not power on.Low or dead batteries; USB cable not connected properly.Replace batteries; ensure USB cable is securely connected to both the monitor and power source.
Cuff does not inflate or inflates too slowly.Air tube not connected; air leakage from cuff; cuff damaged.Ensure air tube is firmly inserted; check cuff for any visible damage or leaks; replace cuff if damaged.
Error message on display (e.g., "E1", "Err").Movement during measurement; improper cuff placement; irregular pulse.Remain still and silent during measurement; re-apply cuff correctly; if error persists, consult a doctor.
Inaccurate or inconsistent readings.Incorrect cuff size; improper arm position; recent physical activity or caffeine intake.Ensure correct cuff size and proper arm positioning; avoid strenuous activity, caffeine, or smoking for 30 minutes before measurement. Take multiple readings.

8. Specifications

FeatureDetail
Product NameElectronic Arm Blood Pressure Monitor
Model NumberCardio A6
BrandThomson
Display TypeLCD
Measurement MethodOscillometric
Cuff Size22-36 cm (Medium Cuff)
Memory Capacity90 memories for 2 users (180 total)
Power SourceUSB Cable (battery-free operation) or 4 x AAA Batteries
Dimensions (L x W x H)14 x 5.5 x 11.6 cm
Weight255 grams
Special FeaturesArrhythmia Detection, Automatic Measurement

9. Warranty and Support

THOMSON products are manufactured to high-quality standards. For information regarding warranty coverage, technical support, or service, please refer to the warranty card included with your product or visit the official THOMSON website. Keep your purchase receipt as proof of purchase for warranty claims.

For further assistance, please contact THOMSON customer service through their official channels.

Related Documents - Cardio A6

Preview Thomson TG585 v8 Wireless Multi-User ADSL2+ Gateway: Setup and User Guide
This setup and user guide provides comprehensive instructions for installing, configuring, and troubleshooting the Thomson TG585 v8 Wireless Multi-User ADSL2+ Gateway. Learn how to connect your devices, secure your network, and utilize advanced features.
Preview Thomson Go Plus Pro Bruksanvisning
Lär dig installera, konfigurera och använda din Thomson Go Plus Pro smarta display med denna omfattande användarmanual. Innehåller säkerhetsinformation, installationsanvisningar, knappfunktioner, inställningar och felsökning.
Preview Manuel d'utilisation Thomson 43UG5C14 Smart TV - Guide Complet
Ce manuel d'utilisation fournit des instructions détaillées pour l'installation, la configuration et l'utilisation de votre téléviseur intelligent Thomson modèle 43UG5C14. Il couvre une large gamme de sujets, des informations de sécurité essentielles aux paramètres avancés.
Preview Manuel d'utilisation Thomson 24HG2S15C - Guide Smart TV Google TV
Manuel d'utilisation complet pour le téléviseur intelligent Thomson 24HG2S15C. Ce guide couvre l'installation, la configuration Google TV, les paramètres, le dépannage et les spécifications techniques pour une utilisation optimale.
Preview Thomson Go Plus Pro: Manual do Utilizador
Este manual fornece instruções detalhadas para a instalação, configuração e operação do Thomson Go Plus Pro Smart Display. Abrange desde informações de segurança e montagem até à configuração inicial, definições do sistema e resolução de problemas.
Preview Thomson Go Plus Pro: Manual de Utilizare Complet
Ghid detaliat pentru instalarea, configurarea și utilizarea ecranului inteligent Thomson Go Plus Pro. Include instrucțiuni de siguranță, ghiduri de operare și informații despre setări.