Introduction

This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your Utilitech Thermoplastic Submersible Utility Pump. Please read this manual thoroughly before use and retain it for future reference.

Important Safety Information

  • Always disconnect power before servicing or cleaning the pump.
  • Do not operate the pump with a damaged cord or plug.
  • Ensure the pump is properly grounded.
  • Do not use the pump for flammable liquids or in hazardous locations.
  • Keep children and pets away from the operating pump.
  • Wear appropriate personal protective equipment (PPE) when handling the pump.
  • This pump is designed for water only.

Product Overview

The Utilitech Thermoplastic Submersible Utility Pump is designed for efficient water removal from various areas. Key features include:

  • Material: Thermoplastic construction for durability.
  • Power: 1/3 HP motor.
  • Flow Rate: 30 GPM (Gallons Per Minute).
  • Cord Length: 10 ft / 3.04 m cord.
  • Voltage: 115 Volts.
  • Style: Submersible design for effective water transfer.
Utilitech Thermoplastic Submersible Utility Pump in its packaging

Image 1: The Utilitech Thermoplastic Submersible Utility Pump shown in its retail packaging, highlighting its key features like 1/3 HP, 30 GPM flow rate, and 10 ft cord.

Technical Specifications

FeatureSpecification
BrandUtilitech
ModelThermoplastic Submersible Utility Pump
MaterialThermoplastic
StyleSubmersible
Power SourceAC/DC
Horsepower (HP)1/3 HP
Flow Rate30 GPM
Voltage115 Volts
Cord Length10 ft / 3.04 m
ColorBlack
Item Weight10 pounds
Package Dimensions11 x 8 x 7 inches
UPC054757098391

Installation and Setup

Unpacking

  • Carefully remove the pump and all accessories from the packaging.
  • Inspect the pump for any signs of damage. Do not use if damaged.
  • Retain packaging for future storage or transport.

Placement

  • Place the pump on a solid, level surface in the area to be drained.
  • Ensure the pump is fully submerged in water for optimal operation and cooling.
  • Avoid placing the pump directly on mud, sand, or debris to prevent clogging.

Connections

  • Attach a suitable discharge hose (not included) to the pump's outlet. Ensure a secure, leak-free connection.
  • Position the discharge hose to direct water away from the area being drained and towards a suitable disposal point.
  • Plug the pump into a properly grounded 115-volt AC outlet.

Operating Your Pump

Starting the Pump

  • Ensure the pump is correctly installed and submerged.
  • Plug the power cord into a grounded electrical outlet. The pump will begin operating immediately.

Stopping the Pump

  • Unplug the power cord from the electrical outlet to stop the pump.
  • Do not allow the pump to run dry for extended periods, as this can cause damage.

Continuous Operation

  • Monitor the pump during operation to ensure it is functioning correctly and not running dry.
  • If the pump stops pumping water, unplug it immediately and check for blockages or low water levels.

Maintenance

Regular Cleaning

  • Disconnect power before any maintenance.
  • Periodically inspect the pump intake screen for debris. Clean any accumulated dirt, leaves, or other foreign objects.
  • Rinse the pump with clean water after use, especially if pumping dirty water.

Storage

  • For long-term storage, clean the pump thoroughly and allow it to dry completely.
  • Store the pump in a dry, frost-free location.
  • Do not store the pump with water inside if there is a risk of freezing.

Troubleshooting

ProblemPossible CauseSolution
Pump does not startNo powerCheck power outlet, circuit breaker, and cord connection.
Pump does not startImpeller jammedDisconnect power, inspect intake for debris, and clear any obstructions.
Pump runs but no waterLow water levelEnsure pump is fully submerged.
Pump runs but no waterClogged intake/dischargeDisconnect power, clear intake screen and discharge hose.
Reduced flowPartial blockageDisconnect power, clean intake screen and check hose for kinks.
Pump cycles on/off frequentlyWater level fluctuationEnsure stable water level or adjust pump placement.

Warranty and Customer Support

Warranty Information

This Utilitech pump comes with a 1-year limited warranty from the date of purchase, covering defects in materials and workmanship. Please retain your proof of purchase.

Customer Support

For technical assistance, replacement parts, or warranty claims, please contact Utilitech customer support. Refer to the product packaging or the official Utilitech website for current contact information.

You can also visit the official Utilitech website for additional resources: www.utilitech.com

Related Documents - Thermoplastic Submersible Utility Pump

Preview Utilitech 50AC-110 Utility Pump: Installation, Operation, Safety, and Troubleshooting Guide
This comprehensive guide provides essential information for the Utilitech 50AC-110 Utility Pump, including detailed safety precautions, step-by-step installation and operation instructions, maintenance tips, troubleshooting solutions, warranty details, and a replacement parts list.
Preview Utilitech Fan-Forced Utility Heater SH-UH-1-T User Manual and Safety Guide
Comprehensive user manual for the Utilitech Fan-Forced Utility Heater, model SH-UH-1-T. Provides essential safety instructions, product specifications, operating procedures, care and maintenance tips, troubleshooting guide, and warranty information.
Preview Utilitech Booster Utility Pump Quick Start Guide | Model 148008
Concise quick start guide for the Utilitech Booster Utility Pump (Model 148008), covering setup, priming, and operation. Learn how to install and use your pump safely.
Preview Utilitech Booster Utility Pump Quick Start Guide
Quick start guide for the Utilitech Booster Utility Pump (Model #148008, Item #0955585), providing essential setup and operation instructions for efficient water transfer.
Preview Utilitech LED Tape Light Quick Reference Guide
A quick reference guide for the Utilitech LED Tape Light (Model LR0005-LED36K60RGBW), providing essential safety information, preparation steps, installation instructions, care and maintenance tips, warranty details, and troubleshooting solutions for optimal use and longevity.
Preview UTILITECH Halogen Work Light MPL1025-C500K9030 User Guide and Safety Information
Get detailed instructions, safety warnings, troubleshooting tips, and warranty information for the UTILITECH Halogen Work Light (Model MPL1025-C500K9030). Learn how to safely operate, maintain, and troubleshoot your work light.